Laserfiche WebLink
RESPONSE LETTER <br /> PERMIT NUMBER: B2405-041 <br /> Hello Anita Chen. See responses to your questions <br /> (IRC R330.6 and R310.2) Please provide dimensions and sill Response:Egress window dimensions provided. <br /> height for all emergency egress windows. Please provide clear <br /> opening area, width and height per IRC R310.2.1 and <br /> R310.2.2 <br /> (IRC M1505.4.4.3) Lower level range was removed to abate a Response: 160 CFM range hood to be installed <br /> code case for an unlawful duplex. (132303-046 and W2210-015) <br /> Please provide range hood fan for new range. 160 CFM <br /> minimum for an electric range and 260 CFM for a gas range <br /> (IRC R330.5, R314 and R315) Please update note, it is not very Response:Note updated. <br /> clear.All smoke alarms to be interconnected, hardwired with a <br /> battery back-up.All carbon monoxide alarms to be interconnected, <br /> hardwired with a battery back-up.Alarms shall be installed in such a <br /> manner so that the detection device warning is audible from all <br /> areas of the dwelling upon activation of a single alarm. <br /> Regards, <br /> George Nganga <br /> CSL Designs <br />