Load Assumptions:
<br /> WindExposure "B" "A" 41PAAA
<br /> - WindSpeed 100 mph
<br /> Roof Type: Asphalt Shingles Q.Peak DUO XL-G10.2 475 41.14 x 87.24 ilii •�
<br /> Racking Weight: 1557 lbs B ♦y A C J O
<br /> Total Weight: 11,3131bs Clamp Zone"A" N/A"
<br /> Distributed load: 2.56 PSF Clamp Zone"B" 0.79-21.65" '" ,..., moi. 3211 Martin Luther King Jr Way S.
<br /> f
<br /> Mods per Row Rail typel+rail type2 Seattle,WA 98144(206)707-9937
<br /> �gF�' K lc
<br /> ? (15)Portrait, (1)row (6)14', (2)14'
<br /> `��°� \,.asy1/ f I (12)Portrait, (1)row (4)14', (2)14'
<br /> /A I
<br /> (11)Portrait, (1)row (4)14', (2)14'
<br /> ,4/ r' Ns ' (10)Portrait, (1)row (4)14', (2)split 14'
<br /> ,i7s1 LTHIS EDGE TOWARDS ROOF RIDGE .66
<br /> Nr .'/-Ti,5n``� `;\ (9)Portrait, (3)rows (2)17 , (2)17' ! 46 THIS DRAWING CONSTITUTES THE
<br /> S� (8)Portrait, (3)rows (2)14', (2)14' CONFFIDENTIAL INFORMATION OF A&R SOLAR
<br /> AND ITS� OES NOT
<br /> .5 ,ON!\L ��`, - ---- CONFER ANY CRIGHOTIN OR LICENSE POSSESSION DTO USE IT
<br /> (7)Portrait, (4)rows (2)14', (2)14' OR THE INFORMATTION DISCLOSED UCETHIHERE IN
<br /> NOR ANY RIGHT TO REPRODUCE THIS
<br /> STRUCT RAL ONLY DRAWING OR ANY PART HERE IN WITHOUT
<br /> THE WRITTEN CONSENT OF A&R SOLAR.
<br /> J� , (6)Portrait, (1)row (2)14', (2)split 14'
<br /> j -s= ` (5)Portrait, (3)rows (2)14', (2)split 14'
<br /> -- (12.00) 1.99
<br /> =_ _ —_ (4)Portrait, (5)rows (2)17', _ = z0 0
<br /> I
<br /> —�`` (3)Portrait, (1)row (2)14', — ,� = 2.3a � P �
<br /> (2)Portrait, (5)rows (2)split 17', m \Y i J } s El—
<br /> Ain U Q
<br /> (3.�0) Q IY
<br /> . _ _ X to
<br /> IRONRIDGE FLASHFOOT 2 ASSEMBLY — 9.00) Or Cr) OU w
<br /> Q 0 ce
<br /> a N z >
<br /> a N G( W
<br /> ED
<br /> Side View, Flashfoot2 Assembly, Portrait Module IRONRIDGE FLASHFOOT 2 IRONRIDGE XR100 RAIL tn ,—I _ }
<br /> Scale: NTS O2 SCALE: NTS/ UNITS IN INCHES O SCALE: NTS/ UNITS IN INCHES W U Q
<br /> Z Q = z
<br /> IRONRIDGE XR100 RAIL C: •• w
<br /> IRONRIDGE XR100 RAIL 24" OC ROOF TRUSS 0 ao C7
<br /> ,� o w
<br /> D N w >
<br /> Ip '—' w
<br /> o
<br /> PV MODULE UNIVERSAL \ a
<br /> FRAME FASTENING `
<br /> T OBJECT
<br /> - UNIVERSAL j 1 1 `
<br /> FASTENINGPV MO .. � _---IT.-._---....,_
<br /> REVISIONS
<br /> ' OBJECT FRAMEDULE _ •• •• • • •
<br /> I7 = �-_ _ REV. # DATE:
<br /> :, �. ```-- - ` 0 Oct 26, 2021
<br /> RAIL �� • • • • • 1 May 17, 2022
<br /> 1_ _ / - .. Y �" 2 Jun 08,2022
<br /> " 3 Jan 05, 2023
<br /> J.
<br /> Mid Clamp, Plan Mid Clamp, Front "
<br /> • • • • •
<br /> DESIGNED: DANIEL H.
<br /> IRONRIDGE 48" TYP. PM: ANDREW HOULE
<br /> A `- FLASHFOOT 2 ATTACHMENT CELL: (262) 331-0485
<br /> ® Mid Clamp Detail 5 Mount Detail (Profile) FLASHFOOT 2 ASSEMBLY
<br /> © Clamping Point Layout A4.2 RACKING-
<br /> Scale: NTS O Scale: NTS BUILDING B
<br /> Scale: NTS
<br />
|