Laserfiche WebLink
PROJECT STATISTICS LEGEND/SYMBOL/ABBREVIATION GENERAL NOTE PLUMBING FIXTURE CALCULATION @IPIVENI <br /> - ALL PIPING INSULATION SHALL MEET THE REQUIREMENTS OF THE CITY ENERGY CODE,2018 EDITION WATER SUPPLY DRAINAGE DESIGN STUDIO <br /> SITE ADDRESS: 8417 EVERGREEN WAY,EVERETT,WA 98208 SYMBOLABBREV.DESCRIPTION - GROOVED FIELD JOINTS(USE 316L STAINLESS STEEL COUPLINGS FOR UNDERGROUND INSTALLATION) FIXTURE - <br /> DISCHARGE TO SANITARY DISCHARGE TO GREASE 9031 21ST AVE SW <br /> LEGAL DESCRIPTION: SEC 13 TWP 28 RGE 04TH PTN NE1/4 NE1/4 SEC 13 TWP 28 -._, POC POINT OF CONNECTION - ALL PIPING INSULATION AND COVERINGS SHALL HAVE AN ASTM FLAME SPREAD RATING OF 25 OR LESS AND AN COLD WATER SUPPLY HOT WATER SUPPLY WASTE WASTE DIRECT INDIRECT VENT SEATTLE,WA 98106 <br /> ROE 4&TH PTN OF GOVT LOT 1 OF SEC 18 TWP 28 RGE 5 OAF- ASTM SMOKE DEVELOPED RATING OF 50 OR LESS DRAIN DRAIN TEL 206.322.4323 <br /> COM AT NE COR OF SO NE1/4 NE1/4 TH$00`41 00E ALG E LN TAG TYPE QTY. SIZE WSFU TOTAL SIZE WSFU TOTAL SIZE FU TOTAL SIZE FU TOTAL FAX.206.322.9177 <br /> SD SUB 633.64FT TH N58*16 15W 36.26FT TO TPBTH CONT �- POD POINT OF DISCONNECT - ELASTOMERIC INSULATIONS WHICH MEET THESE RATINGS MAY BE USED AS A SUBSTITUTE FOR FIBERGLASS WC. WATER CLOSET.ADA 2 3/4" 2.5 5 - - - 3' 4 B - - - / 2° <br /> E-MAIL:INFOWCATCHSTUDIO.COM <br /> N58*16 15W 200FT TO SELY MGN OF EVERGREEN WAY(P.S.H. C— DN PIPE DOWN - INSULATE THE OVERFLOW DRAIN BODY AND PIPE 10 FEET DOWN STREAM FROM THE DRAIN LAV. LAVATORY.ADA 2 1/2" 1 2 1/2' 1 2 2° 1 2 - - - / 1-1/2° WWW.CATCHSTUDIO.COM <br /> NO.1)TH N31*43 45E ALG SD HWY MGN 203.86E7 TAP TH <br /> BEARS S31*43 45W 360FT FR S MGN OFCASINO RD TH S58*16 UP PIPE UP - PROVIDE A COVERING FOR ALL INSULATION EXPOSED TO SIGHT WITHIN THE BUILDING FD. FLOOR DRAIN 1 - 2° 2 2 / 1-1/2' <br /> 15E FOR 200F7 TAP TH BEARS N31*43 45E FR TPB TH S31`43 0— _ PROVIDE AN INCOMPRESSIBLE INSULATED PAD WITH A MINIMUM THERMAL RESISTANCE OF R-10 UNDER ALL (KITCHEN) <br /> 45W 203.87E7 TO TPB FLOW DIRECTION ELECTRIC WATER HEATERS IN UNCONDITIONED SPACES OR ON CONCRETE FLOOR.SEE NOTE ON HWT DETAIL FUNNEL FLOOR DRAIN <br /> FED. (KITCHEN) 1 - - - - - 2' 2 2 - - - / 1-1/2' <br /> PARCEL NUMBER: 28041300104900 I Fi TP TRAP PRIMER W/WALL ACCESS PANEL THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAYBE DUMP SINK 1 1/2" 2 2 1/2° 2 2 - - - 2' 2 2 / 1-1/2' <br /> YEAR BUILT: 2020 1 REQUIRED.THE PLUMBING CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL <br /> RPBA- BFP BACKFLOW PREVENTER CLEARANCES BEFORE COMMENCING WORK. HAND SINK 2 1/2" 2 4 1/2' 2 4 2' 2 4 / 1-V2' <br /> BUILDING GROSS SO FT: 6,409 MATERIALS,METHODS,AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF 72018 EDITION OF CITY 1 COMP.SINK 1 1/2" 2 2 1/2' 2 2 2' 1 2 - - - / 1-1/2' <br /> STORIES: 1 Il r SOV SHUT-OFF VALVE 2 PLUMBING CODE. 3 COMP.SINK 1 1/2' 2 2 1/2' 2 2 - - - 3° 3 3 / 2° <br /> 3 ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. <br /> PROJECT AREA: 2,319 MOP SINK 1 3/4" 3 3 3/4" 3 3 - - - 3' 3 3 / 2' <br /> -NI- CKV CHECK VALVE SLOPE ALL WASTE PIPING AT 2%UNLESS OTHERWISE NOTED ON DRAWINGS.OBTAIN APPROVAL FROM CODE <br /> PRESENT USE: B-RESTAURANT 4 AUTHORITY BEFORE INSTALLING WASTE PIPING AT LESS THAN 2%(EVEN IF LESSER SLOPE IS INDICATED ON DISHWASHER 1 - - - 3/4" 4 4 3' 4 4 - - - / 2° <br /> PROPOSED USE: B-RESTAURANT BALANCING VALVE DRAWINGS). ESPRESSO MACHINE 1 - - - 1/2° 2 2 - - - 2° 2 2 / 1-1/2° <br /> CONSTRUCTION TYPE: V-B I� GCK GAS COOK 5 HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH SECTION 313 AND TABLE 313.3 OF THE ICE MAKER 1 1/2" 2 2 - - - 2° 2 2 - - - / 1-1/2° PROJECT TITLE: <br /> 2018 UNIFORM PLUMBING CODE ICE BIN 1 - - - - - - 2° 2 2 - - - / 1-1/2' <br /> SPRINKLERS: YES el FD FD FLOOR DRAIN PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED <br /> PARKING: ADEQUATE 6 MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. ICE CREAM MACHINE 1 - - - - - - 2° 2 2 / 1 1/2° M 0 C H I N U T <br /> DEED FED FLOOR DRAIN W/FUNNEL FOR EXACT ROUGH-IN LOCATIONS AND ELEVATIONS OF PLUMBING FIXTURES REFER TO ARCHITECTURAL HOT WATER 1 - - - 1/2° 2 2 - - - - - - - <br /> CONSTRUCTION COST: 30,000$ 7 DRAWINGS DISPENSER <br /> 11_d FS FS FLOOR SINK 8 PROVIDE STOPS OR ANGLE VALVES AT ALL FIXTURES TOTAL FU 22 23 26 14 EVERETT <br /> rWCO WCO WALL CLEAN OUT 9 PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS. <br /> APPLICABLE CODE 10 PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. PLUMBING FIXTURE SCHEDULE 8417 EVERGREEN WAY <br /> Z FCO FCO FLOOR CLEAN OUT 11 CLEANOUTS SHALL BE INSTALLED SO THEY ARE READILY ACCESSIBLE. EVERETT,WA 98208 <br /> 2018 UNIFORM PLUMBING CODE(UPC)2018 INTERNATIONAL FUEL GAS CODE(IFGC) WATER HAMMER ARRESTOR PLUMBING EQUIPMENT,VALVES AND TRAP PRIMERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. TAG FIXTURE MAX WATER USAGE DESCRIPTION <br /> WATER KOHLER ADA AND WATER SENSE EPA COMPLIANT 1.28 GPF FLOOR MOUNTED WATER CLOSET(K-3999-RA)CONSISTS OF <br /> 12 UNLESS SHOWN ON ARCHITECTURAL DRAWINGS,REQUIRED ACCESS PANELS SHALL BE PROVIDED BY THE WC CLOSET ADA 128 GAL./FLUSH K-4731-C SEAT,K-4199 BOWL,AND K-4467-RA TANK WITH RIGHT-HAND TRIP LAVER OR EQUAL. SHEET TITLE: <br /> 2018 INTERNATIONAL BUILDING CODE(IBC) —I I I— UNION PLUMBING CONTRACTOR AND INSTALLED BY THE GENERAL CONTRACTOR. <br /> (STATE OF WASHINGTON AMENDMENTS) _ 13-1 RELIEF VALVE FLOORS SHALL SLOPE TO FLOOR DRAINS WHERE DRAINAGE OCCURS ON A REGULAR BASIS.PLUMBER TO LAV LAVATORY. N/A KOHLER SOHO WALL MOUNT LAVATORY#K-2053,DIMENSION L20'X W15',3/8"HOT AND COLD <br /> 13 COORDINATE WITH GENERAL CONTRACTOR FOR EXACT ELEVATION OF DRAIN.(EXAMPLES TOILET ROOMS, ADA PROJECT STATISTICS <br /> 2018 WASHINGTON STATE ENERGY CODE(WSEC) KITCHENS AND LAUNDRY ROOM.) PROFLO MODEL:PFTP2500(FOR UP TO 3FD).TRAP PRIMER VALVES SHALL BE USED WHERE REPLENISHMENT OF WATER IN <br /> 14 THE PLUMBER SHALL PROVIDE AND LOCATE ALL REQUIRED FLOOR,WALL,AND FOOTING SLEEVES FLOOR DRAIN TRAPS IS REQUIRED.MUST BE INSTALLED ON COLD FRESH WATER LINES OF 1-1/2°DIAMETER OR LESS.PFTP35O0 <br /> PROJECT TEAM GENERAL NOTE TO CONTRACTOR HEAT TRACING OF PIPING,WHERE INDICATED,SHALL BE PROVIDED AND INSTALLED BY THE PLUMBING TP. TRAP PRIMER N/A PRIMES UP TO 10 FLOOR DRAINS.PRESSURE DROP OF 3 PSIG(20 KPA)REQUIRED TO ACTIVATE THE PRIMING VALVE.OPERATING <br /> 15 CONTRACTOR.THE PLUMBING CONTRACTOR IS TO COORDINATE THE HEAT TRACE WIRING SUPPLY WITH THE RANGE IS 20 TO 80 PSIG.MACHINED OF CORROSION RESISTANT(LEAD FREE)BRASS.SEE SPEC SHEET ON PAGE PB <br /> OWNER: NAME:THOMAS NGUYEN 1. CONTRACTOR SHALL VISIT JOB SITE,VERIFY FIELD ELECTRICAL CONTRACTOR. ZURN MODEL FD2290 ADJUSTABLE FLOOR DRAIN.CAST IRON BODY,NO-HUB,CHROME PLATED STRAINER.1/2 TRAP PRIMER <br /> TEL: 510.759.8881 CONDITIONS,REVIEW PLAN AND SPECIFICATIONS AND SHALL TRENCHING,BACKFILLING,AND COMPACTING FOR UNDERGROUND PIPING SHALL BE THE RESPONSIBILITY OF FD. FLOOR DRAIN N/A CONNECTION OR EQUAL. <br /> E-MAIL:THOMASN73@GMAIL.COM INCLUDE IN HIS PRICE THE NECESSARY COST TO CONSTRUCT 16 THE PLUMBING CONTRACTOR UNLESS STATED OTHERWISE IN CONTRACT DOCUMENTS. <br /> THIS PROJECT IN ACCORDANCE WITH THE MECHANICAL FS. FLOOR SINK WA ZURN MODEL FD237612"X12"X8"DEEP,2'NO-HUB OUTLET FLOOR SINK WITH HALF GRATER AND BOTTOM DOME STRAINER <br /> DESIGN TEAM: CATCH DESIGN STUDIO DRAWING AND SHALL MEET ALL APPLICABLE CODES. 17 PIPING BURIED IN THE SLAB TO HAVE A PROTECTIVE SLEEVE. <br /> 9031 21ST AVE SW 2. ALL MATERIAL AND EQUIPMENT FURNISHED AND INSTALLED <br /> SEATTLE,WA 98106 SHALL BE NEW,FREE FROM DEFECTS AND SHALL BE 18 PROVIDE THE SEISMIC PROVISIONS FOR THE WATER HEATER. <br /> GUARANTEED FOR A PERIOD OF DNE YEAR FROM DATE OF I-- <br /> CONTACT: NOS NARIN FINAL ACCEPTANCE BY THE OWNER.SHOULD ANY TROUBLE 19 LIMITATION OF HOT WATER TEMPERATURE TO PLUMBING FIXTURES SHALL BE IN ACCORDANCE WITH CHAPTER <br /> TEL:206-322-4323 DEVELOP DURING THE PERIOD DUE TO FAULTY WORKMANSHIP 4 OF THE 2018 EDITION OF THE UNIFORM PLUMBING CODE W to <br /> E-MAIL:NOS@CATCHSTUDIO.COM OR MATERIAL,THE CONTRACTOR SHALL FURNISH ALL EVERGREEN WAY <br /> N> �, <br /> NECESSARY MATERIAL AND LABOR TO CORRECT THE n! •— <br /> PLUMBER: TRAN'SPLUMBING(LICENSE#TRANSP844RM) TROUBLE WITHOUT COST TO THE OWNER. PIPING MATERIAL SCHEDULE ` <br /> 5165 S 160 TH STREET,TUKWILA,WA 98188 3. CONTRACTOR IS TO REVIEW THE PLANS OF OTHER LOCATION PIPING SIZE MATERIAL(FOOTNOTE) JOINT - I I r l <br /> (425)773-8338 DISCIPLINES AND COORDINATE WITH THE WORK OF OTHER DOMESTIC COLD WATER - !�CO <br /> TRADES PRIOR TO INSTALLATION TO AVOID ANY CONFLICT /IRRIGATION 1/2'TO 2' PEX(A) MFR APPROVED -- <br /> ENGINEER,PE: LINDA BURMAN BETWEEN DUCTS,CONDUITS,SPRINKLERS,PIPING,LIGHTINGTl <br /> I 3 <br /> E-MAIL:LINDA@BURMAN.DESIGN FIXTURES,ETC.NO EXTRAS WILL BE ALLOWED FOR 2-1/2°AND 316E STAINLESS STEEL ' 1 1 i • + { 1 ! `, T m /q <br /> DOMESTIC COLD WATER WELDED V <br /> CORRECTION OF CONFLICTS DUE TO LACK OF COORDINATION. LARGER SCH 10(B) I I I I W <br /> ! OuD <br /> 4. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE 1J1 <br /> SANITARY WASTE 1-1/2°TO 4' PVC DWV/ABS SCH 40 SOLVENT CEMENT 1- , <br /> SCALED TO DETERMINE EXACT LOCATION OF PIPING,DUCT UNDERGROUND ' s 4.. ! I @ L Q. <br /> SCOPE OF WORK WORK OR DIFFUSERS. SANITARY WASTE 6°TO LARGER CAST IRON(C) NO HUB ' I — B r` <br /> 5. THE CONTRACTOR SHALL BRING TO THE ARCHITECT'S SANITARY VENT 1-1/2"TO 4' PVC DWV/ABS SCH 40 SOLVENT CEMENT (E)PARKING TRAVEL DISTANCE TO THE MAIN ENTRANCE. I� <br /> ATTENTION OF ANY DISCREPANCY OR CONFLICTS IN THE - rPARKINGANDACCESSAISTESLOPE2%MAXINANYDIRECTION r L- J r� <br /> • FURNISH AND INSTALL PLUMBING FIXTURES AND ASSOCIATED COMPONENTS PLANS OR THE SITE CONDITIONS,ALL NECESSARY CHANGES SANITARY VENT 6"TO LARGER CAST IRON(C) NO HUB �' <br /> PER PLAN. MUST BE APPROVED IN WRITING BY THE ARCHITECT BEFORE NATURAL GAS 1/2°TO LARGER HOPE(D) MFR APPROVED n�j'• ;I,, •°j�j l� <br /> • FURNISH AND INSTALL NEW DOMESTIC WATER PIPING SYSTEM WITH ALL START OR WORK. EEE E <br /> 6. CONTRACTOR TO SUBMIT CATALOG CUT SHEETS OF ALL THE PEX(E,F,A,G)N07E:THE I T I € e I °> .� "� <br /> BACK WALL OF KITCHEN <br /> OTHER ASSOCIATED COMPONENTS PER PLAN. MATERIAL AND EQUIPMENT TO BE USED AND WORKING SHOP i i y I h���®®LI A <br /> HOOD,DOMESTIC WATER t _� �I _�1wi� <br /> • FURNISH AND INSTALL NEW WASTE,GREASE WASTE,AND VENT SYSTEM WITH <br /> DRAWINGS FOR APPROVAL BEFORE START OF WORK. DOMESTIC WATER 1/2°TO 1° MFR APPROVED <br /> 7. SUPPORTS FOR ALL PIPING AND DUCTWORK SHALL BE IN <br /> WILL BE COPPER TYPE.(NO <br /> ALL OTHER ASSOCIATED COMPONENT PER PLAN. ACCORDANCE WITH LATEST SMACNA°GUIDELINES FOR PLASTIC PIPE IN WOOD <br /> WALL) I ,( .• -+o <br /> • INSTALL NEW ELECTRIC 50 GALLON WATER HEATER SEISMIC RESTRAINTS OR MECHANICAL SYSTEMS AND - . <br /> PLUMBING SYSTEMS". DOMESTIC WATER 1-1/4'TO 2• COPPER TYPE(H,G) PRESSED MECH JOINT MOCHINUT EVERETT , <br /> surrE 310..ESw PAN-1 <br /> 2-1/2'AND 304L STAINLESS STEEL PARCELn-MaEH <br /> as0m°wiwvCO <br /> DOMESTIC WATER LARGER SCH 10(B,G) WELDED -=-•n- ' • <br /> • • <br /> FOOTNOTE - • . <br /> PRESSURE ZONE <br /> (A) LIMITED TO 80 PSI @ 200°F DOMESTIC WATER 1/2•TO 2° PEX(E,A) MFR APPROVED I I WING STOP PANDA EXPRESS ' <br /> RISERS °I`-_ su.20-SESTAUS*Nn xsmrtrlsasr5U un • . <br /> -7 CATCH DESIGN STUDIO <br /> GROOVED FIELD JOINTS(USE 316L STAINLESS STEEL ABOVE GROUND PRESSURE ZONE <br /> (B) 2-1/2'AND 304LSTANLESSSTEEL •I DRAWN:NOS NARIN <br /> COUPLINGS FOR UNDERGROUND INSTALLATION) DOMESTIC WATER LARGER SCH 10(B) WELDED <br /> DRAWING INDEX RISERS - <br /> (C) STANDARD NO-HUB BANDS SANITARY WASTE 1-1/2"TO 4° PVC DWV/ABS SCH 40(I,J) SOLVENT CEMENT I <br /> a SCALE:AS NOTED <br /> P1-P2 PROJECT INFORMATION (0) ONLY OUTSIDE BUILDING FOOTPRINT SANITARY WASTE 6"AND LARGER CAST IRON(C) NO HUB - ' - - _ <br /> i i§ .- , , moo_ ' =0 NATIVE FILE: <br /> P3 FLOOR PLAN(FOR REFERENCE ONLY) SANITARY VENT 1-1/2"TO 4° PVC DWV/ABS SCH 40(J) SOLVENT CEMENT I •__-- - <br /> (E) ACCEPTABLE FOR PLENUM USE IN SIZES 1/2"THROUGH 1" �^ ` <br /> NATURAL GAS 1/2°TO 2° BE ERW SCH 40 MEGA-PRESS"G" + > <br /> SANITARY VENT 6°AND LARGER CAST IRON(C) NO HUB Il <br /> P4 WASTE AND VENT RISER PLAN I�'" t <br /> PIPE SHALL BE SUPPORTED IN CHANNEL IN ACCORDANCE WITH 1 <br /> P5 POTABLE RISER WATER PLAN (� ' DATE:10/23/2023 <br /> THE PEX MANUFACTURERS INSTALLATION INSTRUCTIONS. NATURAL GAS 2-1/2 AND <br /> P6 SPEC SHEET LARGER BE ERW SCH 40 WELDED 11111 II ( 11 r <br /> ill* <br /> - <br /> _j <br /> P7 SPEC SHEET (G) PIPE TO BE SUPPORTED DIRECTLY ON HANGERS(NO INSERT OR INDIRECT WASTE 1/2"TO 1-1/4" SCH 40 PVC SOLVENT CEMENT ill* •SHIELD REQUIRES)INSULATION TO BE APPLIED OVER HANGERS ..°' SHEET# <br /> P8 SITE PLAN(REFERENCE ONLY PROVIDED BY LANDLORD) INDIRECT WASTE 1-1/2'TO 2° PVC DWV/ABS SCH 40 SOLVENT CEMENT ••=MIMI•'1•1=1•'••MIll••••• ••r_MM'm ' m m maimmmIMIMIMIIIMM <br /> (H) PRESSURE LIMIT OF 200 PSI UNDERGROUND TRAP PRIMER 1/2" COPPER PRESSED MECH JOINT - <br /> (I) MAY NEED TO CONSIDER ACOUSTICAL REQUIREMENTS ABOVE GROUND TRAP PRIMER 1/2" COPPER PRESSED MECH JOINT SITE PLAN SCALE:N.T.S. P 1 <br /> (J) FLAME/SMOKE SPREAD REQUIREMENTS MAY PRECLUDE USE <br />