My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY 2022 EVERETT 4 CORNERS - BLDG E Plans 2025-07-01
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG E
>
Plans
>
8102 EVERGREEN WAY 2022 EVERETT 4 CORNERS - BLDG E Plans 2025-07-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2025 10:33:52 AM
Creation date
7/1/2025 10:32:46 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG E
Permit
M2206-009
Year
2022
Notes
BUILDING E UNIT VENTILATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENIMI <br /> i SHEET NOTES <br /> 1. LEVELS 2-6 TYPE VA CONSTRUCTION 4> <br /> R2 OCCUPANCIES <br /> 3 IBC SECTION 903.3.1.1(NFPA 13). JOHNSON BSouth �� <br /> 2. ALL LEVELS FULLY SPRINKLERED PER 15200 52ndSO Ave.South <br /> E.g 0 0 0 E.m ® Suite <br /> e me WA98188 <br /> 5' 2 12.. REFER TO SHEETS CS03 FOR FIRE phone 206.766.8300 <br /> / - 129' 8' 3 ASSEMBLY KEY PLAN W/WALL TYPE <br /> / 3T-1" 3T-11" 1' 48•-512 M <br /> " TAGS 8 LOCATIONS.REFER TO vmWlehnsanamM.corn <br /> _ 13'-0" 11'-1012" 13'-0" 11'-10 2" 2'-71/4" 12'-10" 12'-6" 1a-6" SHEETSERIEB A090 FOR ASSEMBLY ARCHITECTURE <br /> A351 / /- -/ /—A A /17 4 DETAILS. INTERIOR DESIGN <br /> SEE ENLARGED UNIT PLANS FOR ALL Greg L aAnne. <br /> INTERIOR DIMENSIONS,WINDOW AND Jelhel A.Wmlams. <br /> 1 r • <br /> Q :1 ialliflaa7A i TAGS <br /> CALL-OUTS,AND RATED WALL <br /> ® 5 EXIT STAIR ENCLOSURES IN TYPE 1A <br /> " ® -- 7A u �7 _ J '� --4 -'— m "o CONSTRUCTION SHALL BE 3HOUR <br /> • E.1 RATED <br /> • <br /> 8• <br /> ALL VERTICAL SHAFTS SHALL BE 2- <br /> r 5•-2" EN 5'-10"/5•-2"/ HOUR RATED PER IBC SECTION 713.4. <br /> • <br /> " le <br /> r7Atli. - 7. 1 DOOR TYPE-SEE SCHEDULE <br /> 7D 7D L I [_1 <br /> OSHEET A100 <br /> / _ 8. REFER TO SHEET SERIES A100 FOR <br /> " I i Y 56 REGISTERED <br /> UNIT PLAN DOOR&WINDOW <br /> /_ SCHEDULE. RCHITECT <br /> ---.. 4ik j UN 2.1 UNIT 2.1 UNIT 4.1 • <br /> L 1 ET I • �7 9. REFER TO SHEETS A710.A720, FFket aurOUH WILLInu <br /> SHE A720U <br /> _ SHEET A120 SHEET A140 <br /> A730,A740,A150&A151 FOR STATE of WASHINGTON <br /> I / b ENLARGED UNIT PLANS. <br /> J 10 REFER TO ACCESSIBILITY NOTES <br /> ON SHEET CS00 <br /> II CI <br /> 1 2 aTrAv <br /> I 11. PROVIDE MECHANICALLY <br /> SIn' FASTENED INSULATION AT ALL ac <br /> I0 1 I0 I ♦ E.3 AND IUNCONDITIONED O SPACE, <br /> EE <br /> F.E.C. 1011 <br /> 7 I 11-j-11F.E.C. <br /> ® Q <br /> CORRIDOR ` 21_,'; STORAGE" REFER TO SHEET A040 FOR <br /> REQUIRED R-VALUES. <br /> CrDP _ A F.E.C. CORRIDOR SHAFT met — 'Ft ^ '®' <br /> 0 O 1r4L <br /> - �� t2. CORRIDOR VENTILATION CONCEPT mi-,_ L —o I13-G 1 G 3T-012' 10 <br /> DEAD END E -1PL - <br /> I <br /> � - F.E.C. RECESSED/FIRE EXTINGUISHER <br /> _ IINI_ <br /> 13. -� CABINET�jp , SEE DETAIL ® `oV tlIw�u n 14 8F.E. SURFACEMOUNTEDFIRE <br /> ��� EXTINGUISHER CABINET <br /> a_I' <br /> R ��f-7A LOCATE PER IBC TABLE 906.1 <br /> rl (1)75 FT.MAX.SEPARATION- a <br /> r v <br /> ' © -_� - _ �I^�.� �_ _ ___—_ Aft PARKING GARAGE LEVEL ONLY z <br /> " --1'-I', -- I ^—J� Ti SEE DETAIL 3/A051 FOR <br /> ® J ® MOUNTING/INSTALLATION 1 <br /> I 222 I 224 : __ I I� HEIGHT 8 <br /> SHEET A120 7D� SH ET A120 I I I SHEET A140 - 15. I EXIT' SIGN PER IBC SECTION 1013. E1 <br /> 7D <br /> 1 - I I 7J 11 I m I '� , 16. REFER <br /> TO DESIGN/BUILD <br /> EL P IIGGN/UILD NS. p S <br /> _ - - L� •—� �- E 6 17. REFER TO SHEET A051 FOR <br /> E.B �i — _ -- — _ PENETRATION REQUIREMENTS IN <br /> O I 'o , 7A J I , m FIRE RATED CONSTRUCTION. U <br /> • xi7+n E q n� : r 18. REFERENCE BUILDING ENVELOPE p <br /> L� 7I DRAWINGS FOR ALL WATERPROOFING. <br /> 3'-212" 11'-1012" 13'-0" 113'-a' 11'-1012" 12'-10" t 1/4" 12'-6" to-8" 19 <br /> INDICATES TYPE A ACCESSIBLE UNIT. o <br /> ,f / a-9 / / ALL REMINING UNITS SHALL MEET TYPE <br /> �4'-1012" 33'-012'• 1" 3T-11" 2 /4" 9'-tC 1/2 21/4" 49-51/2" B ACCESSIBLE UNIT REQUIREMENTS <br /> .( A A .R / .' PER IBC SECTION 1107.6.2 <br /> 3 UNIT D WL 1 O 20. RATED PEREMISING IBC SECTALSIOAREN 708 WH/UR <br /> egg 0 0 <br /> 129'-8" E. E.m MINIMUM STC 50.SEE SHEETS A0408A041 (n <br /> 21.® INDICATES TYPE'A'UNIT C <br /> 22. AT DOORS INTO ELECTRICAL CONTROL E <br /> PANEL ROOMS,SIGNAGE SHALL SE i i <br /> PROVIDED ON THE DOOR STATING <br /> 'ELECTRICAL ROOM' CO Fao- <br /> 23. AT DOORS INTO FIRE PROTECTION • a. 2 <br /> EQUIPMENT ROOMS CONTAINING Q 3 C m <br /> SPRINKLER RISERS,FACP,OR OTHER E m w <br /> SUPPRESION CONTROL ELEMENTS, (A % <br /> APPROVED SIGNAGE SHALL BE L Q'3 8 <br /> PROVIDED AND READILY VISIBLE PER a) - 8 <br /> IFC SECTION 509.1 C w'0 ge <br /> 24. TTWO-WAY COMMUNICATION I. mw' ¢ rn ¢; <br /> .o SYSTEM PER IBC SECTION 1009.8 O y 1 e. <br /> U w o.yma fl <br /> L oz g„,3 ai lj QZS;U. Nofom <br /> c <br /> d <br /> U <br /> el <br /> 6/ <br /> E <br /> 0 <br /> U <br /> 'o KEY PLAN <br /> Li. <br /> n <br /> N <br />, 40 <br /> N <br /> 1 <br /> o PROJECT 1627 <br /> N DRAWN BY: AT <br /> 5 CHECKED BY. ST <br /> e <br /> S <br /> I <br /> BLDG E-FLOOR 2 EAST <br /> U <br /> 3 <br /> BUILDING E A2 51 C <br /> " '--1---\BLDGE FLOOR 2EAST - /L" 0 CONSTRUCTION SET <br /> T. vo_ 09/01/2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.