Laserfiche WebLink
THESE OUTLINE SPECIFICATIONS IN CONJUNCTION WITH THE SPRINT STANDARD CONSTRUCTION SPECIFICATIONS, INCLUDING CONTRACT DOCUMENTS AND THE CONSTRUCTION DRAWINGS <br /> DESCRIBE THE WORK TO BE PERFORMED BY THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR MEETING THE REQUIREMENTS OF SPRINT'S "STANDARD CONSTRUCTION • Z <br /> SPECIFICATIONS FOR WIRELESS SITES" IN REGARDS TO ALL WORK COMPLETED. Sprint U) <br /> w <br /> 0 <br /> REMOTE ELECTRICAL TILT (RET) CABLES: OVERLANDPRINT PA KPKS 66251 w <br /> SECTION 01 100 - SCOPE OF WORK ALTERNATES:SECTION 01 400 - SUBMITTALS & TESTS U) <br /> MISCELLANEOUS: <br /> THE WORK: �' 0 <br /> AT THE COMPANY'S REQUEST, ANY ALTERNATIVES TO THE MATERIALS OR METHODS INSTALL SPUTTERS, COMBINERS, ALTERS PER RF DATA SHEET, FURNISHED BY 0 <br /> SHALL COMPLY WITH APPUCABLE NATIONAL CODES AND STANDARDS, LATEST EDITION, SPECIFIED SHALL BE SUBMITTED TO SPRINTS CONSTRUCTION MANAGER FOR <br /> z <br /> AND PORTIONS THEREOF. APPROVAL. SPRINT WILL REVIEW AND APPROVE ONLY THOSE REQUESTS MADE IN SPRINT. w <br /> WRITING. NO VERBAL APPROVALS WILL BE CONSIDERED, `� J <br /> PRECEDENCE: ANTENNA INSTALLATION: E <br /> THE CONTRACTOR SHALL ASSEMBLE ALL ANTENNAS ONSITE IN ACCORDANCE WITH SHOULD CONFLICTS OCCUR BETWEEN THE STANDARD CONSTRUCTION SPECIFICATIONS W I R E LESS <br /> THE INSTRUCTIONS SUPPLIED BY THE MANUFACTURER. ANTENNA HEIGHT, AZIMUTH, N <br /> FOR WIRELESS SITES INCLUDING THE STANDARD CONSTRUCTION DETAILS FOR TESTS AND INSPECTIONS: AND FEED ORIENTATION INFORMATION SHALL BE A DESIGNATED ON THE 540 W. MADISON ST. U) <br /> WIRELESS SITES AND THE CONSTRUCTION DRAWINGS, INFORMATION ON THE CONSTRUCTION DRAWINGS. SUITE 1600 � <br /> CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE. CHICAGO, IL 60661 m <br /> A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION TESTS, A. THE CONTRACTOR SHALL POSITION THE ANTENNA ON TOWER PIPE MOUNTS SO Lu <br /> x <br /> SITE FAMILIARITY; INSPECTIONS AND PROJECT DOCUMENTATION. THAT THE BOTTOM STRUT IS LEVEL. THE PIPE MOUNTS SHALL BE PLUMB TO FULLEIZTON <br /> CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL <br /> ITN <br /> CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING B. CONTRACTOR SHALL ACCOMPUSH TESTING INCLUDING BUT NOT UNITED TO THE W HIIGREE ENGINEERING DESIGN H <br /> WITH CONSTRUCTION. FOLLOWING: . <br /> 9600 W.BRYN MAWR AVE.,SUITE 200 D <br /> 0 <br /> B. ANTENNA MOUNTING REQUIREMENTS: PROVIDE ANTENNA MOUNTING HARDWARE ROSEMONT,ILLINOIS 60018 <br /> ON-SITE SUPERVISION; 1. COAX SWEEPS AND FIBER TESTS PER THE CURRENT VERSION OF SPRINT AS INDICATED ON THE DRAWINGS. TEL:847-292-0200 H <br /> THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE TS-0200 ANTENNA UNE ACCEPTANCE STANDARDS. FAX:847-292-0206 <br /> RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND HYBRID CABLE INSTALLATION: COA#3151 0 <br /> PROCEDURES IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 2. AGL, AZIMUTH AND DOWNTILT PROVIDE AN AUTOMATED REPORT UPLOADED TO A. THE CONTRACTOR SHALL ROUTE, TEST, AND INSTALL ALL CABLES AS INDICATED www.FullertonEngineering.com F <br /> SITERRA USING A COMMERCIAL MADE-FOR THE PURPOSE ELECTRONIC D <br /> DRAWINGS. SPECIFICATIONS AND DETAILS REQUIRED AT JOBSITE: ANTENNA ALGNMENT TOOL (MT). INSTALLED AZIMUTH, CENTERLINE AND ON THE CONSTRUCTION DRAWINGS AND IN ACCORDANCE WITH THE DESCRIPTION DATE BY REV CO <br /> THE CONSTRUCTION CONTRACTOR SHALL MAINTAIN A FULL SET OF THE DOWNTILT MUST CONFORM WITH RF CONFIGURATION DATA MANUFACTURER'S RECOMMENDATIONS. 90% REVIEW 7/17/15 BE A FT- <br /> CONSTRUCTION DRAWINGS AT THE JOBSITE FROM MOBILIZATION THROUGH FINAL 8/06/15 AS 0 <br /> CONSTRUCTION COMPLETION. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL CORRECTIONS TO B. THE INSTALLED RADIUS OF THE CABLES SHALL NOT BE LESS THAN THE w <br /> ANY WORK IDENTIFIED AS UNACCEPTABLE IN SITE INSPECTION ACTIVITIES <br /> MANUFACTURER'S SPECIFICATIONS FOR BENDING RADII. cc <br /> A. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. PROVIDE ALL MATERIALS AND AND/OR AS A RESULT OF TESTING. o <br /> LABOR AS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. C. EXTREME CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE CABLES DURING <br /> MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND 4. ALL TESTING REQUIRED BY APPUCABLE INSTALLATION MOPS. HANDLING AND INSTALLATION. w <br /> SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. <br /> C. REQUIRED CLOSEOUT DOCUMENTATION INCLUDES, BUT IS NOT UNITED TO THE 1. FASTENING MAIN HYBRID CABLES: ALL CABLES SHALL BE INSTALLED INSIDE MONOPOLE WITH CABLE z <br /> B. CONTRACTOR SHALL NOTIFY SPRINT CONSTRUCTION MANAGER OF ANY VARIATIONS FOLLOWING; SUPPORT GRIPS AS REQUIRED BY THE MANUFACTURER. w <br /> PRIOR TO PROCEEDING WITH THE WORK.DIMENSIONS SHOWN ARE TO FINISH m <br /> SURFACES UNLESS NOTED OTHERWISE. MODIFICATIONS MAY BE REQUIRED TO SUIT 1. AZIMUTH, DOWNTILT, AGL FROM SUNSIGHT INSTRUMENTS - ANTENNAUGN 2. FASTENING INDIVIDUAL FIBER AND DC CABLES ABOVE BREAKOUT ENCLOSURE (MEDUSA), WITHIN E <br /> JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED ALIGNMENT TOOL (MT) THE MMBS CABINET AND ANY INTERMEDIATE DISTRIBUTION BOXES: <br /> AS PART OF THE WORK. a' <br /> C. MARK THE FIELD SET OF DRAWINGS IN RED, DOCUMENTING ANY CHANGES FROM 2. SWEEP AND FIBER TESTS a. FIBER: SUPPORT FIBER BUNDLES USING fi" VELCRO STRAPS OF THE REQUIRED LENGTH 0 18" ♦�/�/,i <br /> F LU <br /> OC. STRAPS SHALL BE UV, OIL AND WATER RESISTANT AND SUITABLE FOR INDUSTRIAL �j'4i p o <br /> THE CONSTRUCTION DOCUMENTS. 3. SCALABLE BARCODE PHOTOGRAPHS OF TOWER TOP AND INACCESSIBLE INSTALLATIONS AS MANUFACTURED BY TEXTOL OR APPROVED EQUAL If I7s,' E <br /> SERIAUZED EQUIPMENT I -, 1)a. '1 a <br /> b. DC: SUPPORT DC BUNDLES WITH ZIP TIES OF THE ADEQUATE LENGTH. ZIP TIES TO BE UV CL <br /> METHODS OF PROCEDURE (MOPS) FOR CONSTRUCTION: 4. ALL AVAILABLE JURISDICTIONAL PERMIT AND OCCUPANCY INFORMATION STABILIZED, BLACK NYLON, WITH TENSILE STRENGTH AT 12,000 PSI AS MANUFACTURED BY w <br /> CONTRACTOR SHALL PERFORM WORK AS DESCRIBED IN NELCO PRODUCTS OR EQUAL m <br /> 5. PDF SCAN OF REDLINES PRODUCED IN FIELD a A. COAX COLOR CODING SWEEPS AND FIBER TESTING TS-0200 AND EL-0568 3. FASTENING JUMPERS: SECURE JUMPERS TO THE SIDE ARMS OR HEAD FRAMES USING STAINLESS fJ�, 52527 0z <br /> 6. A PDF SCAN OF REDLINE MARK-UPS SUITABLE FOR USE IN ELECTRONIC STEEL TIE WRAPS OR STAINLESS STEEL BUTTERFLY CUPS. 00 "TOISTe r <br /> B. CABLE LABEUNG EN-2012-00 AS-BUILT DRAWING PRODUCTION �C� a <br /> 4. CABLE INSTALLATION: sVONAL,V G <br /> C. APPUCABLE INSTALLATION MOPS IDENTIFIED ELSEWHERE IN THE CONTRACT 7. LIEN WAIVERS z0 <br /> DOCUMENTS a. INSPECT CABLE PRIOR TO USE FOR SHIPPING DAMAGE, NOTIFY THE CONSTRUCTION MANAGER. <br /> 8. FINAL PAYMENT APPUCATION z <br /> D. SPRINT GROUNDING SPECIFICATION NE-312-201 b. CABLE ROUTING: CABLE INSTALLATION SHALL BE PLANNED TO ENSURE THAT THE UNES WILL SITE NAME <br /> 9. REQUIRED FINAL CONSTRUCTION PHOTOS BE PROPERLY ROUTED IN THE CABLE ENVELOP AS INDICATED ON THE DRAWINGS. AVOID a <br /> E. SPRINT INTEGRATED CONSTRUCTION STANDARDS VERSION 4.0 TWISTING AND CROSSOVERS. m <br /> 10. CONSTRUCTION AND COMMISSIONING CHECKUST COMPLETE WITH NO DEFICIENT EVERETT u <br /> 0 <br /> SECTION 01 200 - COMPANY FURNISHED MATERIAL AND ITEMS c. HOIST CABLE USING PROPER HOISTING GRIPS. DO NOT EXCEED MANUFACTURES RECOMMENDED <br /> MAXIMUM BEND RADIUS. BAKERVIEW APTS <br /> EQUIPMENT <br /> 11. APPUCABLE POST NTP TASKS INCLUDING DOCUMENT UPLOADS COMPLETED IN w <br /> SITERRA (SPRINTS DOCUMENT REPOSITORY OF RECORD). 5. GROUNDING OF TRANSMISSION LINES: ALL TRANSMISSION LINES SHALL BE GROUNDED AS INDICATED a <br /> COMPANY FURNISHED MATERIAL AND EQUIPMENT IS IDENTIFIED ON THE RF DATA ON DRAWINGS. SITE NUMBER 0 <br /> SHEET IN THE CONSTRUCTION DRAWINGS. 12. CLOSEOUT PHOTOGRAPHS AND CLOSEOUT CHECKUST: SPRINT WILL PROVIDE a <br /> SEPARATE GUIDANCE 6. HYBRID CABLE COLOR CODING: ALL COLOR CODING SHALL BE AS REQUIRED IN THE CURRENT SE82XCO80 <br /> CONTRACTOR IS RESPONSIBLE FOR SPRINT PROVIDED MATERIAL AND EQUIPMENT TO VERSION OF SPRINT TS-0200. En <br /> o <br /> ENSURE IT IS PROTECTED AND HANDLED PROPERLY THROUGHOUT THE CONSTRUCTION SECTION 11 700 - ANTENNA ASSEMBLY. REMOTE 7. HYBRID CABLE LABEUNG: INDMDUAL HYBRID AND DC BUNDLES SHALL BE LABELED AUGMENT I.D. w <br /> DURATION. RADIO UNITS AND CABLE INSTALLATION ALPHA-NUMERICALLY ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE - EN 2012-001, WA-SNO208E14.1 w <br /> SUMMARY: REV 1 <br /> CONTRACTOR RESPONSIBLE FOR RECEIPT OF SPRINT FURNISHED EQUIPMENT AT CELL SITE ADDRESS a <br /> SITE OR CONTRACTORS LOCATION. CONTRACTOR TO COMPLETE SHIPPING AND WEATHERPROOFING EXTERIOR CONNECTORS AND HYBRID CABLE GROUND KITS: _ <br /> RECEIPT DOCUMENTATION IN ACCORDANCE WITH COMPANY PRACTICE. THIS SECTION SPECIFIES INSTALLATION OF ANTENNAS, RRU'S, AND CABLE A. ALL FIBER & COAX CONNECTORS AND GROUND KITS SHALL BE ,5 E ' ' �"` 0 EQUIPMENT, INSTALLATION, AND TESTING OF COAXIAL FIBER CABLE. WEATHERPROOFED. • 2605 15TH ST <br /> SECTION 01 300 - CELL SITE CONSTRUCTION ANTENNAS AND RRU'S: B. WEATHERPROOFED USING ONE OF THE FOLLOWING METHODS. ALL REVI �V F O . S 1T EVERETT,WA 98201 Z <br /> THE NUMBER AND TYPE OF ANTENNAS AND RRU'S TO BE INSTALLED IS DETAILED INSTALLATIONS MUST BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S w <br /> NOTICE TO PROCEED: ON THE CONSTRUCTION DRAWINGS. RECOMMENDATIONS AND INDUSTRY BEST PRACTICES. a <br /> NO WORK SHALL COMMENCE PRIOR TO COMPANY'S WRITTEN NOTICE TO PROCEED SHEET NAME z <br /> AND THE ISSUANCE OF WORK ORDER. HYBRID CABLE: 1. COLD SHRINK: ENCOMPASS CONNECTOR IN COLD SHRINK TUBING AND PROVIDE A DOUBLE WRAP 0 <br /> HYBRID CABLE WILL BE DC/FIBER AND FURNISHED FOR INSTALLATION AT EACH OF 2" ELECTRICAL TAPE EXTENDING 2" BEYOND TUBING. PROVIDE 3M COLD SHRINK CXS SERIES SPRINT <br /> SITE CLEANUNESS: SITE. CABLE SHALL BE INSTALLED PER THE CONSTRUCTION DRAWINGS AND THE OR EQUAL CL <br /> CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WAS Ib MATERIAL APPUCABLE MANUFACTURER'S REQUIREMENTS. <br /> DEBRIS, AND TRASH. AT THE COMPLETION OF THE WORK, CONTRACTOR SHALL 2. SELF-AMALGAMATING TAPE: CLEAN SURFACES. APPLY A DOUBLE WRAP OF SELF-AMALGAMATING SPECIFICATIONS <br /> REMOVE FROM THE SITE ALL REMAINING RUBBISH, IMPLEMENTS, TEMPORARY JUMPERS AND CONNECTORS: TAPE 2" BEYOND CONNECTOR. APPLY A SECOND WRAP OF SELF-AMALGAMATING TAPE IN OPPOSITE z <br /> FACILITIES, AND SURPLUS MATERIALS. FURNISH AND INSTALL 1/2" COAX JUMPER CABLES BETWEEN THE RRU'S AND DIRECTION. APPLY DOUBLE WRAP OF 2" WIDE ELECTRICAL TAPE EXTENDING 2" BEYOND THE SHEET NUMBER Lu <br /> m <br /> ANTENNAS. JUMPERS SHALL BE TYPE LDF 4, FLC 12-50, CR 540, OR FXL 540. SELF-AMALGAMATING TAPE. <br /> 0 <br /> SUPER-FLEX CABLES ARE NOT ACCEPTABLE. JUMPERS BETWEEN THE RRU'S AND 3. 3M SLIM LOCK CLOSURE 716: SUBSTITUTIONS WILL NOT BE ALLOWED. 0 <br /> ANTENNAS OR TOWER TOP AMPLIFIERS SHALL CONSIST OF 1/2 INCH FOAM S P 1 DIELECTRIC, OUTDOOR RATED COAXIAL CABLE, MIN LENGTH FOR JUMPER SHALL cwi, <br /> BE 10"-0". 4. OPEN FLAME ON JOB SITE IS NOT ACCEPTABLE _ <br /> F- <br />