4504 TERRACE DR 2023 Plans 2025-07-22
>
Address Records
>
TERRACE DR
>
4504
>
Plans
>
4504 TERRACE DR 2023 Plans 2025-07-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2025 1:22:30 PM
Creation date
7/1/2025 10:54:12 AM
Metadata
Fields
Template:
Address Document
Street Name
TERRACE DR
Street Number
4504
Permit
B2303-056
Year
2023
Notes
INSTALL 14 PILES TO STABILIZE HOME, & HELICALS 3 & 4 RETROFIT BRACKET (REVISIONS AFTER ISSUED PLAN SET)
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ads <br /> a FOUNDATION NOTES <br /> 15'-0"* / 13'-0"` / 1. VERIFY ALL DIMENSIONS ON SITE. ,.a'T'ti k <br /> U F,, <br /> 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM i*`' <br /> WALL PER R&R LEVEL SURVEY. >- �,J. +: <br /> ^-" 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: ,x <br /> -- HELICAL PILES 1/SD-1.1 <br /> DRIVEN PILES 2/SD-1.1 *•.SIONgL Ef.•• <br /> 225n. 4- REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED AUGUST 27, <br /> SITE 2023,FOR ADDITIONAL INFORMATION,SPECIFICATIONS,AND REQUIREMENTS. <br /> i 5. LEVEL SURVEY PER R&R REPAIR PLAN DATED NOV 30,2022 REFER TO <br /> a = PLAN %3 STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND ADDITIONAL <br /> - REQUIREMENTS FOR REPAIR PLAN. <br /> 1 6. MINIMUM PILE DIAMETER SHALL BE 2-7/8".HELIX CONFIGURATIONS PER <br /> DRIVEWAY - I' PARCEL NO. <br /> �ij 006055022013 R&R TO MEET LISTED DESIGN STRENGTH WITH APPLICABLE FACTORS OF <br /> ACCESS f3,-0"� I ---- 00 SAFETY. <br /> IL p 3Q' 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH 3 0'-6" <br /> 12°• 3", 2 TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED <br /> 44 12- DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS <br /> ' 0 EXCEED THE SPACING LIMITATION OF 8'-0'O.C.MAXIMUM. <br /> It <br /> �4// 8. ALL SUPPLEMENTAL CHANNELS TO SPAN FROM PILE TO PILE AND EXTEND <br /> 4/ MIN 6"PAST SUPPORTING PILE EA END. Q } 6 <br /> -----_-----" 9. ALL SUPPLEMENTAL CHANNELS TO BE ANCHORED TO THE FOUNDATION N <br /> N WITH 5/8"DIAM.x 4`SIMPSON TITEN HD SCREW ANCHORS(OR APPROVED <br /> EQUIVALENT)AT A MAXIMUM SPACING 18"OC.ANCHORS TO BE CENTERED ON H WOVERALL PARCEL PLAN OR INSTALLED ABOVE THE CENTER LINE OF THE CHANNEL. Z <br /> (E)RESIDENCE 10.FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE w <br /> 4504 Evergreen Way, N.T.S. <br /> 9 Y ATTACHMENT LOCATIONS ARE 8"THICK MINIMUM WITH 2'-8"HEIGHT W <br /> Everett,WA 98203 <br /> (MEASURED FROM B/FTG TO TICONC)MINIMUM.FIELD VERIFY EXISTING Z 5 <br /> CONCRETE SLAB-ON-GRADE AT PILE ATTACHMENT IS 4"THICK MINIMUM. O O <br /> 11.PARCEL DIMENSIONS PROVIDED BY CITY OF SNOHOMISH COUNTY.NOT TO J <br /> AREA OF SCALE.PROPERTY LINE AND RESIDENCE LOCATING DIMENSIONS(WITH <br /> /WORK ASTERISK,"(APPROXIMATED PER SNOHOMISH COUNTY iMAP AND SEATTLE <br /> PRIMARY DEPARTMENT OF CONSTRUCTION AND INSPECTIONS GIS MAPPING TOOLS. <br /> ). NOT TO BE USED FOR LEGAL PURPOSES. <br /> ENTRANCE 12.SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT <br /> LOCATE <br /> in UNDER • SHOWN FOR CLARITY. <br /> 7n PILES 13.PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5'-0"OR UNTIL e� <br /> , <br /> tl EXISTING <br /> POST �� 1, SITE PLAN LEGEND REFUSAL,WHICHEVER IS SHALLOWER. . <br /> Ni <br /> co <br /> n EXISTING RESIDENCE STRUCTURE DRIVEN PILE REFUSAL CRITERIA: /' <br /> ADVANCEMENT OF THE PILE SHALL CONTINUE UNTIL A WORKING <br /> e• �11 EXISTING ADJACENT STRUCTURE I PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL <br /> 9 T __ CAPACITY WITH A SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT <br /> LOCATE HELICAL -r• T AREA OF PROPOSED WORK SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE <br /> • <br /> PILE CAPS UNDER ---' UPLIFT FLEXURE. <br /> Pr CONCRETE STEM <br /> EXISTING POST WALL IT-0'TALL MIN TIP AT I PERIMETER * <br /> PROPERTY LINE <br /> NOTIFY L12O PFSOR TO X4)PILES g 6,0'O.C.MAX HELICAL PILE REFUSAL CRITERIA: - <br /> 1 �'`• WORK IF CONCRETE WALL TORQUINGOF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE <br /> cii <br /> Et <br /> U AT PILE LOCATIONS <br /> S IS <br /> LESS THAN 9' TALL 8� ---- APPROXIMATE DIMENSION IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH <br /> to LOCATE PILE WTHIN 2FT A SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED <br /> 4. <br /> MAX OF CORNER '�# HELICAL PILE IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. <br /> N <br /> a (4)PILES p'-O'O.C.MAX ¢ STABIL-LOC PILE <br /> +31 4 4. 5 4. 6 • 7 ® EXISTING POST <br /> -..i�Z 4504 Evergreen <br /> rir Way, Everett,WA <br /> / zs'-o / 98203 <br /> S221213-1XR <br /> 3' 12' <br /> 3' 0 -1/B NJ <br /> LOT SIZE: ci a MRT <br /> 0.66 ACRE(S)(28,750 <br /> SQFT) 3' <br /> PILE SPACING&LOAD REQUIRMENTS TABLE F. =Existing Post 8/27/23 <br /> BUILDING LOT 13' 9 <br /> MAX O.C.SPACING,ft MIN VERTICAL CAPACITY,klps ' PROOF TESTING LOAD,kips DIGGA 6K DIGGA IOK POWER TEAM COVERAGE: -1/a <br /> C25C 9%(2,568 SQFT) -3/8 -1/2 V=3"Helical Pile <br /> PILES PILE TYPE LOCATION 1/4'=t-0" <br /> BM END 204%MIN VERTICAL CAPACITY(MIN ,}=3"Concentric Pier <br /> ALLOWABLE LOADING TORQUE PRESSURE TORQUE PRESSURE PRESSURE <br /> PILES OFFSET ULTIMATE CAPACITY) <br /> #1-2,7-10 DRIVEN 6'.0 3'-0'MAX 1604 3204 TYP . - - - 6,600PSI 56 E =Polyurethane Lift <br /> #3-6 DRIVEN 6'4' 3'0'MAX 1204 240kip TYP - • - - 5000PSI -778 -7/8LOCATE PILES -SB <br /> #14 HELICAL 6.-0' 3'-0'MAX 110 kip 22.0 k.0 TYP 2797FT-LBS 900 PSI 2,784FT-LBS 800 PSI PARCEL NO. SUNDER -1 3/8 <br /> 00605502201300 in POST <br /> NOTES: LEGAL DESCRIPTION -3/4 1 3/4 '"- <br /> a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE VICTORY HEIGHTS ADD TO EVERETT ELK 022 0.00-LOT 13 x •ice •3B Warp _ 9 <br /> MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING TOW TH PTN DAF BEG NE COR LOT 12TH S01`07 30E ALG E • <br /> LN SD LOT 12 DIST OF 65.48FT TH N64`19 04W DIST OF • -1 1/ <br /> CAPACITY LOADING,INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT d <br /> 110.81 FT TH N89`40 31W DIST OF 134.21 FT TAP ON W LN 1 •-1 4 Id)PILES 6'-0'O.C.MAX <br /> EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM § LOCATE CORNER NAT1/N MAX OF -r8 SD LOT 12 TH NO2`12 39E ALGW LN SD LOT 12 DIST OF <br /> INSTALLATION TORQUE RATING OF 8,300FT`LBS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL ® <br /> THICKNESS PER ESR-3750. 18.01FT TO NW CORSD LOT 12 S PT ALSO BEARS N89'40 LOCATE PILE WITHIN <br /> b. FOR HELICAL PILES,PER IDEAL GROUP DWG NO.:278TFG,THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 7/8" 31 W FR POE TH S69'40 31E ALG N LN SD LOT 12 DIST OF 112 m 2 3/ 0 / 1FT MAX OF <br /> 232.10FT TO POB PER CITY OF EVT BLA 1474-17-94 REC AF _ U -2 1/4 - -3 6/8.:A9 CORNER <br /> TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 29 KIPS. NO 94122102438,SURV REC AF NO 9412215006 3 4 <br /> c. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC., IN ACCORDANCE WITH ESR-3750. 28'5 'Y <br /> d. CONCENTRIC DRIVEN PILES AS MANUFACTURED BY STABIL-LOC SYSTEMS,LLC,IN ACCORDANCE WITH ESR-4121. .I`-a;PILEsge-o-o.cMAx- ' <br /> e. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART OWNER NAME&ADDRESS <br /> OF THE ASSEMBLY. MCCORD MELISSA A/SCHMIDT HERMAN W III R&R LEVEL SURVEY <br /> f. MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. 4504 Evergreen Way,Everett,WA 98203 SEE STRUCTURAL CALCULATION PACKAGE FOR ADDITIONAL REQUIREMENTS <br /> g.HELICAL PILE CAPS WILL BE PLACED ON HELICAL PILES 3 AND 4. Z <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. SITE PLAN <br /> UJ <br /> I- <br /> C <br />