Laserfiche WebLink
29ra <br /> GENERA L STRUCTURAL NOTES ABBREVIATIONS A1Hvp <br /> ,.. - <br /> DESIGN CRITERIA HELICAL PEES AB ANCHOR BOLT FTG FOOTING <br /> CODE:2018 IBCIIRC 8 AMENDMENTS AS ADOPTED BY THE REVIEWING AGENCY/COUNTY 1. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2018 INTERNATIONAL ABV ABOVE GA GAUGE �' <br /> ` fir <br /> ROOF 25 PSF SNOW(GROUND) BUILDING CODE(IBC). AFF ABOVE FINISH FLOOR GALV GALVANIZED "".sio ale: .,E;.'" <br /> FLOORS 2. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED BY IDEAL MANUFACTURING,INC.,AND SHALL BE ALT ALTERNATE GLB GLULAM BEAM """ <br /> RESIDENTIAL 40 PSF IN ACCORDANCE WITH ESR-3750. ALUM ALUMINUM GR GRADE <br /> BALCONY/DECK 60 PSF 3. ALL MATERIAL PROPERTIES OF HELICAL PILE COMPONENTS SHALL BE IN ACCORDANCE WITH ESR-3750. APPROX APPROXIMATE GYP GYPSUM WALL BOARD <br /> 4. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES ACCEPTANCE AYC ALASKAN YELLOW CEDAR HOG HOT-DIPPED GALVANIZED <br /> GENERAL CONDITIONS CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING POLYMER(EAA) BB BOO BEAM HDR HEADER <br /> 1. THE CONTRACTOR SHALL EXAMINE THE STRUCTURAL DRAWINGS AND SHALL NOTIFY THE STRUCTURAL COATINGS(AC228). BF BOTTOM FLUSH HE HEM FIR <br /> ENGINEER OF ANY DISCREPANCIES HE MAY FIND BEFORE PROCEEDING WITH THE WORK. 5. ALL HELICAL FOUNDATION COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE BLDG BUILDING HGT HEIGHT <br /> 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE REINFORCING STEEL,BUILDING STRUCTURAL STEEL.OR ANY OTHER METAL BUILDING COMPONENTS PER BLKG BLOCKING HT HEIGHT <br /> STARTING WORK.THE ARCHITECT/ENGINEER SHALL IMMEDIATELY BE NOTIFIED IN WRITING OF ANY AC358 SECTION 3.9. BM BEAM IN INCH <br /> DISCREPANCIES. 6. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS. BOT BOTTOM JT JOINT <br /> 3, ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS SHALL 7. ONLY MANUFACTURER-APPROVED CONNECTORS,ADAPTORS,AND ACCESSORIES MAY BE USED. BP BOTTOM PLATE MAX MAXIMUM <br /> BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER BEFORE 8. HELICAL PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE OF BRG BEARING MIN MINIMUM W <br /> PROCEEDING WITH ANY WORK SO INVOLVED. INCLINATION OF*/-1 DEGREE FROM VERTICAL PER SECTION 4.2.1 OF ESR-3750. BTWN BETWEEN MISC MISCELLANEOUS Q } 6 <br /> BSMT BASEMENT <br /> 4. IN CASE OF CONFLICT, NOTES AND DETAILS OF THESE STRUCTURAL DRAWINGS SHALL TAKE 9. MONITOR AND RECORD DEPTH OF PILE PENETRATION.PROVIDE TORQUE MONITORING DEVICE AS PART OF NB NON-BEARING of <br /> B/W BOTTOM OF WALL z O <br /> PRECEDENCE OVER THE°GENERAL NOTES"AND/OR'STANDARD DETAILS'. THE INSTALLING UNIT.MONITOR AND RECORD TORQUE APPLIED DURING THE INSTALLATION OF EACH PILE NO NUMBER <br /> 5. IF A SPECIFIC DETAIL IS NOT SHOWN FOR ANY PART OF THE WORK,THE CONSTRUCTION SHALL BE THE AT SPECIFIC DEPTHS. <br /> CANT CANTILEVER <br /> CI CONTROL JOINT <br /> OC ON CENTER z <br /> SAME AS FOR SIMILAR WORK. 10. HELICAL PILES SHALL BE INSTALLED TO THE MINIMUM TORQUE VALUE REQUIRED TO PROVIDE THE PSF POUNDS PER SQUARE FOOT f 15 0• <br /> CLG. CEILING t/ W <br /> 6. WORKING DIMENSIONS SHALL NOT BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THESE MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF SAFETY NO LESS PSI POUNDS PER SQUARE INCH 7 W z <br /> THAN TWO CU CEILING JOIST L <br /> DRAWINGS. (2).THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CLR CLEAR PT PRESSURE TREATED O z (9 <br /> 7. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE STRUCTURAL ENGINEER OF ANY CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE PILE ASSEMBLY. CMU CONCRETE MASONRY UNIT RAF RAFTER Q W <br /> CONDITION WHICH IN HIS OPINION MIGHT ENDANGER THE STABILITY OF THE STRUCTURE OR CAUSE 11. ALL BRACKETS AND HELICAL PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY TO ACHIEVE COL COLUMN REF REFERENCE J <br /> DISTRESS TO THE STRUCTURE. THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO(2). CONC CONCRETE REINF REINFORCEMENT <br /> 8. THE CONTRACTOR SHALL SUPERVISE AND DIRECT HIS WORK AND HE SHALL BE SOLELY RESPONSIBLE 12. REPAIR BRACKETS MUST BE CONCENTRICALLY LOADED AND THE BRACKET PLATE MUST BE FULLY CONN CONNECTION REQD REQUIRED <br /> FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. PROVIDE ENGAGED WITH BOTTOM OF CONCRETE FOUNDATION. CONST CONSTRUCTION SF SQUARE FOOT <br /> 13. ALL HELICAL PILE ASSEMBLY COMPONENTS MUST HAVE ADEQUATE STRENGTH DEVELOP THE TORQUESIMILAR TOCONT CONTINUOUS SIM ili <br /> ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. <br /> 9. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE LATEST EDITION OF THE REQUIRED FOR INSTALLATION AND ALL INDUCED STRESSES. CTR CENTER SPF SPRUCE PINE FIR <br /> INTERNATIONAL BUILDING CODE,AND ALL OTHER REGULATING AGENCIES EXERCISING AUTHORITY OVER 14. THE PILE QUANTITY,LAYOUT,AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED WITHOUT DET DETAIL STD STANDARD _ -.e� I ANY PORTION OF THE WORK. WRITTEN APPROVAL FROM THE ENGINEER-OF-RECORD PRIOR TO INSTALLATION. DF DOUGLAS FIR(SOUTH) SYP SOUTHERN YELLOW PINE <br /> 10. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. 15. CONTINUOUS SPECIAL INSPECTION IN ACCORDANCE WITH 2015 AND 2018 IBC SECTION 1705.9 MUST BE DEL DOUGLAS FIR LARCH T/ TOP OF <br /> WHERE THE NOTES,DRAWINGS,AND/OR SPECIFICATIONS DIFFER,THE MORE STRINGENT REQUIREMENT PROVIDED FOR THE INSTALLATION OF THE HELICAL PILES AND FOUNDATION BRACKETS.ITEMS TO BE DIM DIMENSION T/C TOP OF CONCRETE /' <br /> SHALL APPLY. RECORDED AND CONFIRMED BY THE SPECIAL INSPECTOR MUST INCLUDE THE FOLLOWING: DI DOUBLE JOIST T/P TOP OF PLATE <br /> 11. REFER TO THE ARCHITECTURAL DRAWINGS FOR INFORMATION NOT COVERED BY THESE GENERAL NOTES A. PRODUCT MANUFACTURER DIA DIAMETER T/S TOP OF STEEL <br /> OR THE STRUCTURAL DRAWINGS. B. MANUFACTURER'S CERTIFICATION OF THE INSTALLERS DN DOWN T/W TOP OF WALL <br /> 12. NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. C. PRODUCT TYPE AND CONFIGURATIONS FOR HELICAL PILE LEAD SHAFT SECTIONS,EXTENSIONS, DS DOWN SPOUT TF TOP FLUSH <br /> 13. DISCREPANCIES FOUND BETWEEN STRUCTURAL DRAWINGS AND OTHER DOCUMENTS ARE TO BE NOTED BRACKETS,BOLTS,THREADED RODS,NUTS,WASHERS,AND TORQUES AS SPECIFIED IN THIS EACH Ti TRIPLE JOIST <br /> IN WRITING TO THE ENGINEER PRIOR TO CONSTRUCTION. REPORT AND THE CONSTRUCTION DOCUMENTS EF EACH FACE T/BM TOP OF BEAM _ <br /> 14. ALL CONSTRUCTION SHALL BE DONE WITH MATERIALS,METHODS,AND WORKMANSHIP ACCEPTED AS D. INSTALLATION PROCEDURES FOR THE HELICAL PILE SHAFT,INSTALLATION EQUIPMENT USED,AND EXPANSION JOIFIT <br /> EL.EV ELEVATION T/SIAOTOP OF SLAB <br /> THE IDEAL FOUNDATION SYSTEMS INSTALLATION INSTRUCTIONS TP/ TOP PLATE <br /> GOOD PRACTICE BY THE CONSTRUCTION INDUSTRY IN CONFORMANCE TO THE PROVISIONS OF THE EN EDGE NAILING(PANEL) <br /> "INTERNATIONAL BUILDING CODE"(IBC),AND STANDARDS REFERENCED THEREIN. E. ANTICIPATED AND ACTUAL PILING DEPTH EQ EQUAL TYP TYPICAL <br /> F. REQUIRED TARGET INSTALLATION TORQUE OF PILES AND MINIMUM DEPTH OF INSTALLATION <br /> 15. STRUCTURAL STABILITY OF ALL NEW AND EXISTING STRUCTURES DURING CONSTRUCTION SHALL BE ES EACH SIDE UNO UNLESS NOTED OTHERWISE <br /> THE RESPONSIBILITY OF THE CONTRACTOR.THIS INCLUDES EXCAVATIONS,COLUMNS,EQUIPMENT G. INCLINATION AND POSITION OF PILES.TOP OF PILE EXTENSION IN FULL CONTACT WITH BRACKET, EW EACH WAY UPA UNDER POST ABOVE <br /> LOADS,MATERIAL LOADS.AND OTHERS.OBSERVATIONS BY THE ENGINEER-OF-RECORD DO NOT TIGHTNESS OF ALL BOLTS AND EVIDENCE THAT THE PILE FOUNDATION SYSTEMS ARE INSTALLED FB FLUSH BEAM UWA UNDER WALL ABOVE <br /> BY AN APPROVED IDEAL FOUNDATION SYSTEMS INSTALLER. <br /> INCLUDE INSPECTIONS OF TEMPORARY LOADING AND STABILITY DURING CONSTRUCTION. FIN FINISH VERT VERTICAL <br /> 16. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION.MISALIGNMENT,OR FAILURE TO MEET OTHER FL FLOOR VIF VERIFY IN FIELD <br /> SPECIFIED DESIGNANSTALLATION CRITERIA ARE NOT ACCEPTABLE.ABANDON REJECTED PILES AND FLSHG FLASHING W/ WITH 5117 23rd Ave W <br /> INSTALL ADDITIONAL PILES AS REQUIRED. FND FOUNDATION WC WESTERN CEDAR Everett,WA 98203 <br /> FP FIREPLACE WP WATERPROOF <br /> CONCRETE ANCHORS HELICAL PILE PROOF TESTING FT FOOT WWFWWF��IRE FABRIC <br /> 1. ALL SPECIFIED CONCRETE ANCHORS SHALL BE SIMPSON STRONG TIE.HILTI,OR EQUIVALENT.SPECIAL THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE(3) \ <br /> INSPECTIONS REQUIRED. PERCENT OF PILES UP TO FIVE(5)PILES MAXIMUM(ONE(1)MINIMUM)IN ACCORDANCE WITH THE PROCEDURE <br /> OUTLINED IN ASTM D1143 AND/OR THE 2018 INTERNATIONAL BUILDING CODE(IBC).THE MAXIMUM TEST LOAD ` S230130-2XR <br /> STRUCTURAL AND MISC.STEEL SHALL BETWO-HUNDRED(200)PERCENT OF THE SPECIFIED DESIGN LOAD. SPECIAL INSPECTIONS SCHEDULE <br /> 1. REFERENCE STANDARDS:DESIGN,FABRICATION AND ERECTION ARE TO BE IN ACCORDANCE WITH THE PAM <br /> LATEST EDITION OF THE AISC'CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES". SPECIAL INSPECTIONS TABLES PER THE 2018 IBC.ALL ITEMS NON-APPLICABLE ITEMS HAVE BEEN <br /> 2. MATERIALS: MARKED WITH A-'.ITEMS REQUIRING SPECIAL INSPECTION HAVE BEEN MARKED WITH AN'X'. M RT <br /> BOLTS-ASTM A307,UNLESS OTHERWISE NOTED <br /> WF BEAMS-ASTM A572-50(Fy=50,000 PSI) TABLE 1705.3 TABLE 1706.7 03/17/2023 <br /> HSS ROUND COLUMNS-ASTIR A500 Gr.B(Fy=42,000 PSI) REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION REQUIRED SPECAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS <br /> HSS RECTANGULAR COLUMNS-ASTM A500 Gr.B(Fy=46,000 PSI) CONTINUOUS PERIODIC SPECW. REFERENCED 6C TYPE CONTINUOUS SPECIAL INSPECTION PERIODIC SPECIAL INSPECTION <br /> TYPE SPECIAL INSPECTION BTANDARD REFERENCE 1 Venty ekmem nalenals safes and lengths eompy wen x <br /> ALL OTHER STEEL-ASTIR A36(Fy=36,000 PSI) INSPECTION Me reguiremems - <br /> I Inspect remtorcemenl amiud,ng prestress,. ACI 318 Ch.20.25.2 19<,3a 2 Determine capacities a rest elements and conduct x - <br /> tendons and verity placement - - 253 26.51-26 53 addemnal Med tests as requeed. <br /> STRUCTURAL STEEL WELDING 2 Rernferong ear wemmg 3 Inspect drying operatons and tna 0100,0mpeee and x _ <br /> of reinforcing oars accurate records for each element <br /> 1. CONFORM TO THE AWS CODES DU AND D3.3.,AND USE ONLY CERTIFIED WELDERS.WELDS NOT a Veay n Wner Man ASTC0105705 - - AWS DI! a Veny placement locations and pwnemess connnn <br /> b Inspect singe maximum-Pans Diet welds.maxum ACI 318.2654 type and site of hammer,record number of blows per <br /> SPECIFIED ARE TO BE 1/4"CONTINUOUS FILLET MINIMUM.USE DRY E70 ELECTRODES. - root of penebamd determine required penetrations to x - <br /> acneve desgn capacity record tip and bun Me/aliens <br /> c Inspect all Other welds. - and document any damage to rompalpn element <br /> ALTERNATES: 3.Inspectamt,rs cast,concrete - - ACI318.1782 - 5 For steel elements.perform addilmnal Special - - <br /> 1. ALTERNATE ASSEMBLIES AND MATERIALS WILL BE CONSIDERED FOR REVIEW.ENGINEER MAY REQUEST a inspect amrorspost-msealledinaraoned empecpansin accordance eEC Section-..nL. <br /> concrete menlhets 6 For concrete elements and concrete-plkd elements. - - <br /> PAYMENT FOR REVIEW;CONTRACTOR WILL BEAR BURDEN FOR ADDITIONAL PAYMENT AT NO ADDITIONAL mica AalmesNe ancnms Installed m rpncomzl dorm Jews and eaten 1al513 Insoectwns In <br /> h dance with SecdOO 1al special <br /> COST TO OWNER. m upwardly tens.Pads <br /> to re5dl - - ACI 318175.24 - 7 Fm Spefaly elements.performaddllpnal e1p0,000S - - Ln <br /> sI farmed Ienslnn pads as deternmed by me registered design professiawl m LLI <br /> b Alechancai anchors and ahesne anchors - - responsible charge I-- <br /> JOBSITE SAFETY: WI dellne0 in.1 a - - ACI3,a cn 19 1904 1.,9w 2. 0 <br /> 1. THE ENGINEER AND/OR ARCHITECT HAVE NOT BEEN RETAINED OR COMPENSATED TO PROVIDE DESIGN s'erM useafegW`ea aeSg"'"ax 26a3 26e4 19082 19053 z <br /> 6 Pner 0 concrete placement Ianrcale specenen5 ASTIR C 172 <br /> AND/OR CONSTRUCTION REVIEW SERVICES RELATED TO THE CONTRACTOR'S SAFETY PRECAUTIONS OR roc shengm tests.pedamsbmpand air - - ASTIR C3, ,90810 J <br /> anent tests and ememvne the loeCeramre of ACI 3,8 26 a 5.2612 Q <br /> TO MEANS,METHODS,TECHNIQUES,SEQUENCES OR PROCEDURES FOR THE CONTRACTOR TO PERFORM t'000Al2`e K <br /> rd <br /> 7 Inspect concrete and'hdcrete pavement for ACI3,8 26 a 5 1908 6.1908 7. <br /> HIS WORK.THE UNDERTAKING OF PERIODIC SITE VISITS BY THE ENGINEER AND/OR ARCHITECT SHALL ppem appaxon R.I.., 19058 D <br /> NOT BE CONSTRUED AS SUPERVISION OF ACTUAL CONSTRUCTION NOR MAKE HIM RESPONSIBLE FOR enTear,maintenance of specified M� - - AC1368 26A 7.2649 19089 <br /> PROVIDING A SAFE PLACE FOR THE PERFORMANCE OF WORK BY THE CONTRACTOR,SUBCONTRACTORS, 9 inspect ptesdimconcrete for s and - - ACI318 26921 - <br /> p G Wpnp or banded prestress..N.Mre - - ACI 318.26.9.2.3 cc <br /> SUPPLIERS OR THEIR EMPLOYEES,OR FOR ACCESS,VISITS,USE,WORK,TRAVEL,OR OCCUPANCY BY ANY 10 Inspect erernnn of precast concrete n°9Ca5 - - AC1318 Cn 266 - <br /> PERSON. 5'tn concrete s 1l of tendons m post-tensienedconCC'ete and - - AC1318 26102 -pert,removal of shores and morns from J F-I <br /> beans and structural sacs <br /> . <br /> 12 Inspect farm..for en shape....and <br /> aMe commie memeerbeing - - ACI 318 26 101(b) - cc cri <br /> torme <br /> Z <br /> LL <br /> C7 <br />