4230 GRAND AVE 2022 Plans 2025-07-01
>
Address Records
>
GRAND AVE
>
4230
>
Plans
>
4230 GRAND AVE 2022 Plans 2025-07-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2025 11:12:16 AM
Creation date
7/1/2025 11:12:08 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
4230
Permit
B2210-013
Year
2022
Notes
HELICAL PILES TO STABILIZE FOUNDATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o1G L. FOUNDATION NOTES <br /> PARCEL,NO. 1. VERIFY ALL DIMENSIONS ON SITE. - •. <br /> 00422000000600 - 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL :Qs'Sa','L'K.✓•• <br /> LOT SIZE PER R&R LEVEL SURVEY. :<' f : <br /> LEGAL DESCRIPTION 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: j <br /> GEMMILL MANOR BLK 0.16(6,969.SQFT) fry r <br /> HELICAL PILES 11SD-1.1 <br /> 000-D00-LOT 6 •... • <br /> BUILDING LOT HELICAL wISTEEL CHANNEL PILES 2ISD-1.1 ...• <br /> 00010 COVERAGE STEEL CHANNEL INSTALLATION 3/SD-1.1 <br /> 15%(2,920 SOFT) 4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED SEPTEMBER 13, <br /> OWNER NAME& 2022,FOR ADDITIONAL INFORMATION,SPECIFICATIONS.AND REQUIREMENTS. <br /> ADDRESS V, 5. LEVEL SURVEY PER R&R REPAIR PLAN DATED JULY 22,2022 REFER TO <br /> JEFFREY ERIC SUMMEFy N zip, 2 STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND ADDITIONAL <br /> 4230 Grand Ave,Everett, •-s'�` <br /> REQUIREMENTS FOR REPAIR PLAN. <br /> / WA 98203 a2'o"' / PARCEL NO. 9Ltn 6. MINIMUM PILE DIAMETER SHALL BE 2-7/8".HELIX CONFIGURATIONS PER R&R TO <br /> IXM220000006°° MEET LISTED DESIGN STRENGTH WITH APPLICABLE FACTORS OF SAFETY. <br /> ♦` 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH±0'-6" <br /> SLAB WALKWAY O(♦ \ TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED <br /> la <br /> \ \ DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION OF 8'-0"O.C.MAXIMUM. Q } <br /> 's - .___..._...�._.._,..._ ., -..r. .....___.__......-_,._r...T__ _._.,�.- __.._._,.- „_,.�._.,,.,�„ \ \ 8. ALL SUPPLEMENTAL CHANNELS TO SPAN FROM PILE TO PILE AND EXTEND MIN 6 <br /> ---, ` ,ije_ - 6"PAST SUPPORTING PILE EA END. D ~ w <br /> SITE - -' 9. ALL SUPPLEMENTAL CHANNELS TO BE ANCHORED TO THE FOUNDATION WITH I— LLI <br /> PLAN 5/8"DIAM.x 4"SIMPSON TITEN HD SCREW ANCHORS(OR APPROVED EQUIVALENT) R Z <br /> N AT A MAXIMUM SPACING 18"0C.ANCHORS TO BE CENTERED ON OR INSTALLED L/ r E <br /> AREA OF ED ABOVE THE CENTER LINE OF THE CHANNEL. <br /> (E)RESIDENCE WORK OVERALL PARCEL PLAN 10.FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT O O y <br /> 4230 Grand Ave,Everett, N.T.S. LOCATIONS ARE 8"THICK MINIMUM WITH 2'-8"HEIGHT(MEASURED FROM BIFTG TO 1 <br /> WA 98203 T/CONC)MINIMUM.FIELD VERIFY EXISTING CONCRETE SLAB-ON-GRADE AT PILE <br /> _ • ATTACHMENT IS 4"THICK MINIMUM. <br /> HEAT SITE PLAN LEGEND t1.PARCEL DIMENSIONS PROVIDED BY CITY OF SEATTLE.NOT TO SCALE. <br /> PUMP PROPERTY LINE AND RESIDENCE LOCATING DIMENSIONS(WITH ASTERISK,') <br /> 1 APPROXIMATED PER SNOHOMISH COUNTY MAP AND SEATTLE DEPARTMENT OF 4 <br /> o ATA11 ��A10 ATA9 ATA8 ���7 c EXISTING RESIDENCE STRUCTURE CONSTRUCTION AND INSPECTIONS GIS MAPPING TOOLS.NOT TO BE USED FOR <br /> RI TAT VAT TAT TAT AT N • LEGAL PURPOSES. <br /> '� ' r <br /> x (2)PILES @S'-0"O.C.MAX • EXISTING ADJACENT STRUCTURE 12.SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT <br /> I SHOWN FOR CLARITY. <br /> 14.PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5'-0"OR UNTIL <br /> AREA OF PROPOSED WORK <br /> REFUSAL,WHICHEVER IS SHALLOWER. - -- <br /> AVA6 ATA8 .T.4 .TA3 AVA2 ATA1 2 <br /> • <br /> TAT VAT VAT TAT TAT VAT * PROPERTY LINE HELICAL PILE REFUSAL CRITERIA: <br /> tEl ecaHcaeTE STEM TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS <br /> WALL 1.4'TALL MIN TYP AT <br /> NOTIFY L1la PRIM T° LOCATE PILE R-0' ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH A <br /> WORKFCOXCI✓£IE WALL D.C.MAX FROM ---- APPROXIMATE DIMENSION AT PILE LOCATIONS IS CORNER <br /> SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED - <br /> .`.. <br /> • <br /> • LESS TMAN Ta-T� IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. <br /> 1 `` +4, HELICAL PILE <br /> x <br /> \ 6 5 1 g \ <br /> Y AVA# 20"COMPOSITE PAD <br /> v.. <br /> k I \LOCATEPILE1. <br /> WI ADJ.4x6 BRACKET <br /> (5)PILES @ d'-0"O.C.MAX -0" <br /> O.C.MAX FROM <br /> CORNER <br /> 4230 Grand Ave, <br /> SLAB WALKWAY <br /> Everett,WA 98203 <br /> A <br /> Lil <br /> }IX Z 5220802-1 XR <br /> fY 1- w� NJ <br /> a w >U <br /> / 42'-0"• / o¢0 <br /> Slab Watkyay MRT <br /> 42 ' <br /> CExe2 channel metal.at (2)PILES @ '-0'O.C.MAX 9/13/22 <br /> Via contractor's disaetim <br /> eased performance <br /> .LI2o <br /> �k��cI ;,� I 1 t' c. 1/4=1'-0" <br /> PI+tM�" �'.%2r <br /> ..t 1M .-t t'ld <br /> • <br /> a2t 2 LOCATE PILE 6-0• <br /> PILE SPACING&LOAD REQUIRMENTS TABLE OC.MAX FROM <br /> Powr. ___..__ f CORNER <br /> PILE MAX O.C.SPACING.R MIN VERTICAL CAPACITY.kips PROOF TESTING LOAD.kips s 1 s Slat;w�Kway t <br /> c6' <br /> Q 3•Helical Pile <br /> PILE 3t BTWN END P 200%MIN VERTICAL CAPACITY LOCATION 1 4 I 1 a_ 20 compoa- Pan <br /> TYPE PILES OFFSET ALLOWABLE LOADING (MIN ULTIMATE CAPACITY) I "With Atll.4x48rackel <br /> 71-2 HELICAL 8'-0' .�-0'MAX 5 0 kip IC C kip TYF (5)PILES @ 8'-0.O.C.MAX LOCATE PILE 1'-0" <br /> 4 HELICAL 2'-C' :i-0'MAXI2-0 kip 24 C kip TYP O.C.MAX FROM <br /> 7 CORNER <br /> NOTES: _�2� <br /> a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH Q <br /> ENOUGH TO ACHIEVE THE REQUIRED BEARING CAPACITY LOADING,INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THEr J <br /> PILEOW ALLOWABLE TORSIONAL <br /> CAPACITY THICKNESS E3S PER OR <br /> ANY PART OF THE PILE ASSEMBLY.MAXIMUM INSTALLATION TORQUE RATING OF 8,300FT'LBS FOR A 2-7/8 INCH DIAMETER HELICAL R&R LEVEL SURVEY a <br /> z <br /> b. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC.,IN ACCORDANCE WITH ESR-3750. SEE STRUCTURAL CALCULATION PACKAGE FOR ADDITIONAL REQUIREMENTS 0 <br /> c. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART OF THE ASSEMBLY. <br /> d. MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. Q <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. FOUNDATION P LAN QZ N <br /> 0 <br /> L_ <br />