• ' C) <br /> m z PILE SPACING&LOAD REQUIREMENTS TABLE <br /> • <br /> FOUNDATION NOTES O mm .4)PILES @6'-0"OCD9IAX MAX O.C.SPACING,ft MIN VERTICAL CAPACITY,kips PROOF TESTING LOAD,kips • . <br /> m m w af DJ <br /> CA PILE 1t PILE TYPE 200%MIN VERTICAL CAPACITY LOCATION �.'. <br /> 1. VERIFY ALL DIMENSIONS ON SITE. m 2 n1 44' BTWN PILES END OFFSET ALLOWABLE LOADING t�"' `' <br /> (MIN ULTIMATE CAPACITY) j <br /> • <br /> 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER R&R LEVEL SURVEY. N o .- j 1-4 6'-0" 10.0 k/PILE 20.0 k/PILE EXTERIOR 'i <br /> 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: j s a C m m A A v N 5,9 6'-0" 11.0 k/PILE 22.0 k/PILE EXTERIOR ,••ro'-E• .• <br /> HELICAL PILE 1/SD-1.1 c1 `!KT-I to W X m 11 <br /> c) m O m J m 6-8 HELICAL PER PLAN 11.0 k/PILE 22.0 k/PILE POSTS <br /> DRIVEN PILE_ 71SD-1.1 Ed X m *_ 10 1 m v - ------------- 10 6'-0" PER PLAN 7.0 k/PILE 14.0 k/PILE EXTERIOR <br /> 4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED DECEMBER 2ND,2022,FOR ADDITIONAL INFORMATION,SPECIFICATIONS, mZi m 0 z m <br /> Lb <br /> AND REQUIREMENTS. z m a I m 11,14 6'-0" 13.0 k/PILE 26.0 k/PILE CHIMNEY <br /> 5. LEVEL SURVEY PER R&R REPAIR PLAN DATED SEPTEMBER 29TH,2022.REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR r- C)v I 3 12-13 PER PLAN 11.0 k/PILE 22.0 k/PILE CHIMNEY <br /> C) N <br /> MODIFICATIONS AND ADDITIONAL REQUIREMENTS FOR REPAIR PLAN. 'or 1-2 8'-0" 10.0k/PILE 20.0k/PILE BEAM <br /> N CONCENTRIC <br /> 6. MINIMUM PILE DIAMETER SHALL BE 2-7/8'. _ -I0 6 _ .- v Oi . s - de 3 6'-0" 12.0 k/PILE 24.0 k/PILE EXTERIOR <br /> 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH t 0'E"TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS Z E II W 1,::_ Ar, NOTES: <br /> ENCOUNTERED DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION AS INDICATED m 2 m <br /> ON LEVEL SURVEY. 8 Z _ (� a.MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIESSHRLL BE SPECIFIED BY THE PILE <br /> 9. FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8'THICK MINIMUM WITH 2'8'HEIGHT 0 m MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING <br /> y O ti CAPACITY LOADING,INCLUDING AN <br /> SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT <br /> (MEASURED FROM B/FTG TO T/CONC)MINIMUM. �' EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM UJ <br /> 10.PARCEL DIMENSIONS NOT TO SCALE.PROPERTY LINE AND RESIDENCE LOCATING DIMENSIONS(WITH ASTERISK,')APPROXIMATED PER - INSTALLATION TORQUE RATING OF 8,300FT'LBS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL o - <br /> SNOHOMISH COUNTY iMAP.NOT TO BE USED FOR LEGAL PURPOSES. _ W p - THICKNESS PER ESR-3750. <br /> 11.SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FOR CLARITY. OD W . 0 b.FOR HELICAL PILES,PER IDEAL GROUP DWG NO.:278TFG,THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 7/8" D Z o <br /> -�, f � - TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 30 KIPS. <br /> 12.PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5'-0"(UNO PER GEOTECHNICAL REPORT). 21-,r0 ICJ t1 } c. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC., IN ACCORDANCE WITH ESR-3750. I-_ W O <br /> O-4 n ,9 S d.PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART > C <br /> Z-I W OF THE ASSEMBLY. F- w <br /> HELICAL PILE REFUSAL CRITERIA: OO m o n .b ® e.MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. W z <br /> TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL , O II II II II 11 Z O <br /> CAPACITY WITH A SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS m m Z 0 CZ O, W (..2m O O w <br /> TO EXPERIENCE UPLIFT FLEXURE. 2 Q§A O=_ A X x - En <br /> __> a o i g, / > 3� m co ^• SITE PLAN LEGEND -� <br /> �,1 IS DRIVEN PILE REFUSAL CRITERIA O_Z m m m m m m rn = On_+ <br /> ADVANCEMENT OF THE PILE SHALL CONTINUE UNTIL A WORKING PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL a o_ ID N V W a 13 o Ea EXISTING RESIDENCE STRUCTURE <br /> CAPACITY WITH A SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS m m n 0 m 8. m Q 6 a , .. <br /> TO EXPERIENCE UPLIFT FLEXURE. D f. m m ,.__; EXISTING ADJACENT STRUCTURE 1�r <br /> �? : AREA OF PROPOSED WORK --' <br /> R&R LEVEL SURVEY <br /> See Structural Calculation Package for Additional Requirements PROPERTY LINEz if <br /> ---- APPROXIMATE DIMENSION <br /> I <br /> I 1211 HOYT AVE I - <br /> EVERETT,WA 98201 <br /> Ii. <br /> - - -------- .-. . . . . " PROPERTY LINE. . . . . . . .i <br /> I 1213 HOYT AVEo sE,a--`g4`0"-""-, .-,•,.- »-r -•••••- - •�„ 121,D•' .-.-" <br /> CO #1 f , EVERETT <br /> 290 "WArp,- � � I 6-0 1 T.„ -,- �_. __ � <br /> .rraR_,, <br /> PRIMARY w"�.E <br /> i ACCESS ! �� »E',.e� x„. <br /> I <br /> ! �w "'�..,"_. I S221012-3XR <br /> f I �DRI�- V�EWAy A <br /> w I AREA OF WORK ! I ACCESS i I JT <br /> I /yWe <br /> i I= DENCE <br /> 1213HOYTAVE `4 I i MRT <br /> w l'. O EVERETT,WA 98201 I / ' <br /> °-'' PARCEL NO. N T 12/02/2022 <br /> �I 00409422800900 1A i <br /> I ! 2 <br /> ' LEGAL DESCRIPTION I I N C rn <br /> CHURCH&LA MOURES SUPPL BLK 228 ' <br /> ! D-00-BLK 228N 15FT LOT 9&S20FT I ! o' I N <br /> ''1 <br /> If LOT10 fm <br /> r I OWNER NAME&ADDRESS I 1 <br /> I I WELLS-EDWARDS PAUL J&ANDREA L I (E)CHIMNEY I4A*SPh <br /> 1213 HOYT AVE .} II <br /> E I EVERETT,WA 98201 6,-0„ I I II <br /> I i e/ <br /> i j <br /> s PROPERTY LINE i <br /> 1217 HOYT A.E <br /> EVERETT.WA 98201 <br /> C <br /> I Z <br /> i Q cJ <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. I 0 <br /> SITE PLAN Ln <br />