Laserfiche WebLink
olc <br /> 23rd ST <br /> SITE PLAN NOTES -`' <br /> •1. VERIFY EXISTING STRUCTURES AND ALL DIMENSIONS ON SITE. ',.��'( �. �� <br /> 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL •. <br /> 7/V.---- <br /> PER R&R FOUNDATION SPECIALIST(R&R)LEVEL SURVEY. <br /> 3. REFER TO STRUCTURAL CALCULATIONS PACKAGE BY L120 DATED JAN 3. <br /> 2023,FOR ADDITIONAL INFORMATION,SPECIFICATIONS,AND <br /> REQUIREMENTS. <br /> 4. LEVEL SURVEY PER EAR PROPOSAL DATED NOV 22.2022.REFER TO <br /> STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND <br /> ADDITIONAL REQUIREMENTS FOR LEVEL SURVEY. <br /> 5. PARCEL DIMENSIONS APPROXIMATED BY SNOHOMISH COUNTY ASSESSOR <br /> PROPERTY LINE _________________________—_______—.—-—-—-—-—• GIS MAPPING TOOLS&TAXSIFTER INCLUDING THE SELECTED PARCEL. <br /> r-—'—\ ---------------"—'—"—"—"—"—"------------- — — —•— —•-------•_----121'-0"'--__----__----_----_ PROPERTY DIMENSIONS ARE APPROXIMATE FOR REPRESENTATIVE <br /> DRIVEWAY I PURPOSES ONLY.NOT TO SCALE.NOT TO BE USED FOR LEGAL PURPOSES <br /> ACCESS I OR IN PLACE OF FIELD SURVEY. <br /> • I 6. SITE FEATURES AND SOME EXISTING STRUCTURES ON ADJACENT PARCELS }C Z <br /> - I NOT SHOWN FOR CLARITY. D I— U <br /> Iz ❑ <br /> I I— W C <br /> • I V <br /> SITE PLAN LEGEND W yry <br /> _ Z <br /> I EXISTING RESIDENCE STRUCTURE 0 7111 <br /> LL <br /> ; N ' <br /> I <br /> EXISTING ADJACENT STRUCTURE _J <br /> 1 1 <br /> I , AREA OF PROPOSED WORK <br /> 1 <br /> (IL 1riD°• 5•-0"• sr-o-- sa'; ". •-•- PROPERTY LINE '�r <br /> w j X�a'tytAx�Iy (6)PILES Q 6'OC MAX '}I Z * APPROXIMATE DIMENSION <br /> JI I Ih h I �'• <br /> w:r \ \Y Y - Sid_ HELICAL PILE '' <br /> o 'T �- s 1 r a;" 1 <br /> S I 70 <br /> �LOCATE PEE WITHIN MA% CC1 ,'OF CORNER O.i <br /> 1 `o A <br /> ' 'fI8 p f <br /> LL1 I 70 (E)RESIDENCE ; >— <br /> Q ; 1 2303 Oakes Ave 1 LLJ <br /> I w Everett,WA 98281I J <br /> LLl I \ 9 (l IE)IP CONCRETE STEM ' JN <br /> i WALL 2'-Y TALL MRI TYP AT I <br /> . - PRIMARY COVERED II PNonPTii�oPRgRTo ; <br /> ; "' ENTRANCE ENTRY I LOCATECORNER <br /> WTRN IF CONCRETE WALL I <br /> I d'OF CORfER MAX LEAS THAN Y.Y TALL ' 40Zik - <br /> 0 <br /> fa T i0 - - - - - - - - - - - - - PROPERTYLINE--—-—-—-—-—-—-—-—-—-----—-— — — — — — — — — — — — — — ' <br /> \ - - - - - - - - - - - - - - - - - - - - - - - -121.0 2303 Oakes Ave <br /> Everett,WA 98281 <br /> S221216-1XR <br /> PARCEL NO. PAM <br /> 00439149300100 4'MAX <br /> Y (6)PILES @ 6'OC MAX—4' MRT <br /> LEGAL DESCRIPTION I • • . - 19 <br /> EVERETT PLAT OF BLK 493 0 0'; 01/03/2023 <br /> v <br /> D-00-LOTS 1&2 0� m s �B' <br /> - <br /> a Bl <br /> OWNER NAME&ADDRESS A N . m <Beams> • A. <br /> BALMER JOHN&AMY o ;, m C _ <br /> 2303 Oakes Ave ,_ 8 n —- — — ITIj <br /> Everett.WA 98281 i -,X v <br /> L.o• - <br /> s o 8 <br /> .se BE <br /> o0 <br /> a <br /> om O <br /> z <br /> NOTES: z m <br /> SI = <br /> a.MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE .-- _ <br /> �! n <br /> MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING zz FL <br /> LOADING,INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT PILE SPACING 8 LOAD REQUIRMENTS TABLE <br /> EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM MAX O.C.SPACING.ft MIN VERTICAL CAPACITY,kips PROOF TESTING LOAD.kips <br /> INSTALLATION TORQUE RATING OF 8,300FT•LBS FOR A 2-718 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL PILE# PILE TYPE BTWN END 200%MIN VERTICAL CAPACITY LOCATION <br /> THICKNESS PER ESR-3750. PILES OFFSET ALLOWABLE LOADING (MIN ULTIMATE CAPACITY} R&R LEVEL SURVEY <br /> b.HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC.,IN ACCORDANCE WITH ESR-3750. <br /> c.PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART -. HELICAL 6-0' 4-C' 90 kip 'SO Rip NORTH&SOUTH WALLS SEE STRUCTURAL CALCULATION PACKAGE FOR ADDITIONAL <br /> OF THE ASSEMBLY. C HELICAL 6-C' 89i Hp cC kip kEST'd AL <br /> d.MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. REQUIREMENTS <br /> SITE PLAN co <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. LiJ <br /> NOTE:L120'S SCOPE IS LIMITED TO THE PERIMETER SUPPORT SYSTEM/CONTINUOUS FOOTINGS.THE INTERIOR CRAWL SPACE SUPPORTED SYSTEM FOR THE FIRST FLOOR SHALL BE INSTALLED PER R&R. `" <br />