My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9824 HOLLY DR 2022 Plans 2025-07-02
>
Address Records
>
HOLLY DR
>
9824
>
Plans
>
9824 HOLLY DR 2022 Plans 2025-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 8:54:15 AM
Creation date
7/2/2025 8:52:57 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
9824
Permit
B2210-049
Year
2022
Notes
NEW MANUFACTURED HOME AS DADU
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Install Footings <br /> Will footings be concrete? <br /> 110. YES,go to STEPS, SIZE FOOTING, (p. 31). <br /> I. NO,see footing system manufacturer's instructions,then go t0 Set <br /> the Home(p 38) <br /> STEP 5. SIZE FOOTINGS j <br /> Once the load on the footing and the soil bearing capacity are known, calculate the size <br /> of each footing as follows: <br /> 1. From Table 9 determine if the pier is to be of single stack blocks(8 inch x16 <br /> inch)or double stack blocks(16 inch x 16 inch). <br /> 2. Locate the group of columns in Table 10 with the soil bearing capacity deter- <br /> mined in Prepare the Site,STEP 5.DETERMINE SOIL BEARING CAPACITY <br /> AND FROST LINE(p. 17). Use the next lowest value if the exact value does <br /> not appear. <br /> 3. Find the row corresponding to the pier capacity required by Tables 5,6 or 7. <br /> Then, read across the table to determine the minimum required footing area for <br /> the corresponding pier capacity and soil bearing capacity. <br /> 4. The required footing size and pier capacity may be changed by selecting differ- <br /> ent <br /> support spacing <br /> TABLE 9.PIER CONFIGURATION <br /> Maximum load Ohs)Pier Confi- Height Configuration <br /> guration Without With <br /> Mortar Mortar <br /> Single Single stack blocks with long side <br /> Stack Less than 36 in. perpendicular to frame I-beam or 5,760 7,680 <br /> parallel to perimeter rail(rim joist) <br /> Doubts 67"Max. Double,interlocked blocks 11,520 15-360 ' <br /> Stack <br /> Triple 67"Max. Triple,interlocked blocks 17,280 23,034 <br /> Stack <br /> Double 108'Max.'• Double,interlocked blocks NA 39,500 <br /> Reinforced <br /> •Single stack piers may be constructed up to 54" max. height only when installed as pe- <br /> rimeter and marriage line support piers. <br /> "Cross reference maximum allowable pier height with maximum floor height listed in <br /> frame tiedown charts. If maximum height listed in frame tiedown charts is exceeded then <br /> designs must be provided by a registered professional engineer or registered architect. <br /> � ‘10)111‘�," p,l1NI<<�i�i. <br /> fz 3 io.,.. -. , 1 <br /> 0. <br /> _ , .. .,_ , .,, <br /> __. <br /> ... . <br /> ... . <br /> '*' (1,FF <br /> __ _.__ <br /> 31 <br />
The URL can be used to link to this page
Your browser does not support the video tag.