stall Stabilizing <br /> Systems <br /> Install Stabilizing Systems <br /> This chapter covers the design and installation of the stabilizing system which secures the home against lateral and up- <br /> ward forces caused by wind. The system covered here uses earth (or ground)anchors and steel straps connected to the <br /> home's longitudinal steel beams and/or exterior walls. Stabilizer plates may also be used to prevent the anchor head from <br /> moving laterally in the ground. An anchor, strap and stabilizer plate(if used)together are referred to as a tie down_ <br /> Follow the Steps below: <br /> ✓ STEP 1.DETERMINE ANCHOR LOCATIONS(p.74) <br /> T STEP 2. DETERMINE TIEDOWN CONFIGURATION(p. 89) <br /> ✓ STEP 3. SELECT ANCHORS(p 89) <br /> 'T STEP 4. INSTALL ANCHORS(p. 90) <br /> ✓ STEP 5. INSTALL STRAPS(p. 91) <br /> ✓ STEP 6.TIGHTEN AND ADJUST STRAPS(p.94) <br /> STEP 1. DETERMINE ANCHOR LOCATIONS <br /> Create a sketch of the home plan showing the exterior walls, marriage line(s) (if any) <br /> VA <br /> and frame I-beams(this will be similar to the base sketch created in Install Footings. ZAP; <br /> page 20). <br /> Need for a stabilizing sys- <br /> See Table 17 for a list of anchor locations. types and where they are required. Page tern. The home must be se- <br /> numbers where the requirements are provided are noted in the last column cured against the wind by <br /> as- <br /> As each anchor location is determined, mark it on the sketch, noting important dimen- sethe use of an anchor e <br /> sions such as spacing between anchors When complete,this will be the home's tie foundation <br /> ou da or an alternative <br /> down plan Figure 52 and Figure 53 site oraoth system. Where <br /> site other conditions pro- <br /> TABLE 17. ANCHOR LOCATION TYPES habit the use of the manufac- <br /> location I Type Wind Zone I Wind Zones II See page turer's instructions, a regis- <br /> and Ill tered engineer or registered <br /> Frame Yes Yes 75 architect must design the <br /> Sidewall stabilizing system. Alternate <br /> Vertical No Yes 87 foundation designs must be <br /> Frame Yes Yes 87 approved by the manufac- <br /> Longitudinal tururer and DAPIA Refer to <br /> Vertical No No - <br /> He ticai No Yes 89 page 8 for directions for ob- <br /> attiee line V <br /> arrig taming available approved <br /> Frame Yes Yes 88 desgns. <br /> Tag Unit <br /> Vertical No Yes - <br /> Porch Post Vertical Yes Yes 89 <br /> Offset Unit Yes Yes 89 II E' Install marriage line anchors prior to moving the home over the top of the anchor locations a a 2 [1 <br /> then return to Set the Home or Complete Multi Section Set respectively. <br /> APR 132023 <br /> • CITY OF EVERETT <br /> a Permit Services <br /> -74 <br /> IYVE kr Lk_ t..44____. <br /> S-{Ch 1, i INS Sy S ity\s <br /> ` c t'Cit L ixi--- 7.--zt, _qt./ <br />