8102 EVERGREEN WAY 2022 EVERETT 4 CORNERS - BLDG C Plans 2025-07-02
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG C
>
Plans
>
8102 EVERGREEN WAY 2022 EVERETT 4 CORNERS - BLDG C Plans 2025-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 9:46:17 AM
Creation date
7/2/2025 9:45:24 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG C
Permit
M2206-007
Year
2022
Notes
BUILDING C UNIT VENTILATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q <br /> mm C.j C.k 0 n IMIIII <br /> SHEET NOTES <br /> 1. LEVELS 28 TYPE VA CONSTRUCTION <br /> R2 OCCUPANCIES <br /> JOHNSON BRAUND., <br /> I 2. ALL LEVELS FULLY SPRINKLERED PER 15200 52nd Ave.Sash <br /> IBC SECTION 903.3.1.1(NFPA 13). Sude 300 <br /> CORRIDOR 3 REFER TO SHEETS CS03 FOR FIRE Seattle, <br /> 8A7 98188 <br /> 7C ( 500 I - III ASSEMBLY KEY PLAN W/WALL TYPE ,r ,lo,630S aura can <br /> /� Lrl TAGS 8 LOCATIONS.REFER TO <br /> C-8 •__ [(!� - - m - - C8 SHEET SERIES A040 FOR ASSEMBLY ARCHITECTURE <br /> �I DETAILS. INTERIOR DESIGN <br /> ®, r r I C I 4. SEE ENLARGED UNIT PLANS FOR ALL Grey L Alhtine. <br /> _ I lion INTERIOR DIMENSIONS,WINDOW AND Jeffrey A.NAINamg, <br /> 0 �'— ,, m 12F ... <br /> I 7A '� 1DOOR CALL-OUTS,AND RATED WALL <br /> 503 I II A333 TAGS <br /> --fl 1 _ EXIT STAIR ENCLOSURES IN TYPE to <br /> RATED <br /> o� W D '� 5. CONSTRUCTION SHALL BE 3HOUR19 — Q r-■ ALL VERTICAL SHAFTS SHALL BE 2- <br /> 76 —I '� L 6_ HOUR RATED PER IBC SECTION 713.4. <br /> NI All _ _ I / I �- - -�� 7. 1 DOOR TYPE-SEE SCHEDULE <br /> SHEET I �EMU I 0 O SHEET A100 <br /> • I I 7C INgT 21 ) e. REFER TO SHEET SERIES A100 FOR 6556 <br /> 7C <br /> 7C T GE 514 I :o n UNIT PLAN DOOR 8 WINDOW REGISTERED <br /> 7DIV 10'-8" 1 , SHEET A120 SCHEDULE � ' ARCHITECT <br /> 9. REFER TO SHEETS A110,A120, <br /> /\ —�`_ - � _ !-7 /� A130,A140,A7508A751 FOR STATE or WASHNGTOnr- C.10 - _ - -- - - .i I - _2•-0^.I.-p - —C,10 ENLARGED UNIT PLANS. <br /> I <br /> �/ 7Amr I C' C � II `l 10. REFER TO ACCESSIBILITY NOTES STum <br /> IIII 1MINIIIMIE <br /> I U u II ON SHEET CS00 <br /> 5 5n �' U k <br /> 3'-31/2" 10'-0' I LL <br /> 11. PROVIDE MECHANICALLY §. <br /> •IPI4Bh <br /> m FASTENED INSULATION AT ALL <br /> 24'-8 2" / . CEILINGS BETWEEN CONDITIONED Ei • <br /> �- m � m - --o,V AND RTHEEAUNCONDITIONED SPACE, s <br /> REFER TO SHEET A040 FOR <br /> D— I REQUIRED R-VALUES. <br /> I. <br /> 1 I m (. I 12. SHOWN,REFER TO DESIGN/BUILD <br /> T d <br /> m 2qCORRIDOR VENTILATION <br /> _ ® MECHANICAL PLANS <br /> 1 SHEET A130 I I_ i3'-0" <br /> N A432 -— —1- -—-—-—-—r—- m��� F EC RECESSED/FIRE EXTINGUISHER <br /> _1 13 CABINET Q <br /> 7A'� _ SEE DETAIL: <br /> IZIW <br /> L1'-0"'i 4'-0" c <br /> II 1 UNIT 3.l 14 F.E. SURFACE MOUNTED FETE n <br /> au Dill <br /> IISHER CABINET ..7 <br /> 512 I LOCATEEXTINGU PER IBC TABLE 906.3 <br /> b it I - SHEET A130 (1)75 FT.MAX.SEPARATION- S <br /> -- - J ., PARKING GARAGE LEVEL ONLY <br /> L � a SEEONETAIL TING/NSTA FOR <br /> _L F— �_ _ MOUNTING/INSTALLATION <br /> 2•-0".� ' ElmV3 II 4'-PI�1'-0" HEIGHT <br /> © I - r Y 15_ EXITI SIGN PER IBC SECTION 1013. - <br /> I—— X <br /> I ELECTRICAL PLANS <br /> w 1 I b 16. REFER TO DESIGN/BUILD 5- <br /> 1 <br /> v .ti. .... <br /> — - • -- 17. REFER TO SHEET AO51 FOR a-- <br /> ? L_=_- <br /> DN <br /> ' 2'-0' PENETRATION REQUIREMENTS IN <br /> FIRE RATED CONSTRUCTION. <br /> C qgr I •, I 18. REFERENCE BUILDING ENVELOPE <br /> 'TAIR M3 II DRAWINGS FOR ALL WATERPROOFING. <br /> �� UP ST-3 C.' !lII&ig! I <br /> S 1 g B <br /> b m . ^ IJ I 10 LJ m II m A333 19 INDICATES TYPE AACCESSIBLE UNIT. c <br /> _ _ .— --- _`- ALL REMINING UNITS SHALL MEET TYPE <br /> "— B ACCESSIBLE UNIT REQUIREMENTS i <br /> tv r__-�I - - ------ LIALr! ' .. • m. -, PER IBC SECTION 1107.6.2 € <br /> 17D1 mod_ <br /> CORRIDOR SHAFT UNIT DEMISING WALLS ARE 1 HOUR <br /> A332 \ 20' RATED PER IBC SECTION 708 W/ <br /> / b el NIT 4.1 MINIMUM STC 50.SEE SHEETS A0408A041 (A <br /> ,) SHEET 1 El 11 SHE ET A740 II 21.® INDICATES TYPE'A'UNR g <br /> I I 1 22. AT DOORS INTO ELECTRICAL CONTROL E <br /> I. PANEL ROOMS.SIGNAGE SHALL BE 'L 1 <br /> �Ivil II PROVIDED ON THE DOOR STATING <br /> L I Allp M ' 'ELECTRICAL ROOM' (O !! <br /> 11, ph, <br /> � 23' AT DOORS INTO FIRE PROTECTION <br /> 0 EQUIPMENT ROOMS CONTAINING Q 38 <br /> Ilia <br /> b I ` , , J I SPRINKLER RISERS,FACP,OR OTHER "5 <br /> SUPPRESION CONTROL ELEMENTS, Cl) u Q <br /> •� w: �• APPROVED SIGNAGE SHALL BE L <br /> LL ^ PROVIDED AND READILY VISIBLE PER m g <br /> ' ' '-I �e IFC SECTION 509.1 " N m n ; <br /> Idna _ L�JI 24' TTWO-WAY COMMUNICATION L m w' i <br /> y <br /> SYSTEM PER IBC SECTION 1009.8 0 J <br /> L W a <br /> 17, I - <br /> �I ! ---- __-11 fri -k <br /> • o t 3'0= Na <br /> �\ i N a QLL�ma <br /> U2'-0" I _ 7A <br /> to I I III <br /> 15-501 I <br /> b <br /> G b I 7A -____ b <br /> U <br /> 'o C.1 � ��I�i • ,_ ..._, <br /> - 14 KEY PLAN <br /> • LL aI ��-- `-' <br /> cEl <br /> N0 17-Y m iT-10' <br /> � 6s-a" <br /> Alk <br /> Lx 0 rair COCD1® _ a <br /> PROJECT*. 1827 <br /> 4 DRAWN BY: AT <br /> g CHECKED BY: ST <br /> E <br /> BLDG C-FLOOR 5 <br /> q SOUTH <br /> 1111111 <br /> ai <br /> �^�J BUILDING C A234A <br /> Ly BLDG C-LEVEL S SOUTH © V f, CONSTRUCTION SET <br /> LT. 1I5=l'-b` -- 09/01/2021 <br />