Laserfiche WebLink
i III <br /> - - GENERAL UNIT PLAN NOTES <br /> . -— 1. LEVELS LEVELS <br /> TYPE V-A <br /> 0 <br /> ecv Q ALL LEVELS FULLY SPRINKRFIRE PER STIV 13. JOHNSON BRAUNDev 2" I I 2. SEE SHEETS A040-4041 FOR FIRE-RESISTIVE ASSEMBLY TYPES <br /> --- I 2' -�-_I TYPICAL WALL TYPE 15200 52n0 Ave.SglU <br /> �QI LEVELS 2 TO 6-TYPE V-A CONSTRUCTION Suite 300 <br /> 1 O SeaMe,WA 98188 <br /> 7C CORRIDOR WALL PhoneH521:E6.8300 <br /> I.I ,, 7A EXTEROR WALL <br /> ._.: 6,7661.0nbraxae corn <br /> • - .)'. - ARCHITECTURE <br /> ��•�� --111 UNIT DEMISING WALLS INTERIOR DESIGN <br /> IIff 1CD 2 7B INTERIOR WALL(NON-LOAD BEARING) Greg L.Jeffrey A lYAne. <br /> FIZ'LER 35 1 B1 INTERIOR WALL(LOAD BEARING) <br /> 3. REFER TO OWNER PROVIDED FINISH&FIXTURE SCHEDULES. <br /> TYPE'B'BATHROOM ( 8 TYPE'B'BATHROOM <br /> 1/4"=1'-0" 1/4"=1'-0" 4. OX DOOR TYPE-SEE DOOR SCHEDULE ON SHEET A100 <br /> © QIll 5. O WINDOW TYPE-SEE UNIT WINDOW SCHEDULE ON SHEET A100 <br /> I ) } 6. ALL UNITS ON AN ACCESSIBLE STORY SHALL COMPLY WITH WASHINGTON STATE <br /> n _ (ICC/ANSI 117.1)0"TYPE R".SEE FLOOR PLANS FOR LOCATIONS. <br /> • • O2' ` e �2�� •e TOWEL BAR FNE PERCENT F TOTAL NUMBER OF UNITS ARE DESIGNATED AS'T(PE A"UNITS <br /> 05 11 ' '' BLOCKING SEE SHEET A020 FOR TYPE A CALCULATION.SEE FLOOR PLANS FOR LOCATIONS 8556 <br /> rt SEE UNIT SHEETS FOR"TYPE A"AND'TYPE B"UNIT PLANS. REGISTERE D <br /> z CO O � � SEE ACCESSIBILITY NOTES SHEET A550 N I ARCHITECT <br /> =—= _. i :ti\>}3:1SvtiC" �\1._,ram"-N. �, SEE SHEET A550 FOR ACCESSIBLE DETAILS <br /> a w� = `,,_, ,titer e_ J <br /> �_E-��i�e �1 7. REFER TO SEPARATE ELECTRICAL&MECHANICAL DRAWINGS eenel axtut�x nliillfl <br /> r e7 I I <br /> _l\ `t.:,rl� * ---�--' {-J �� (DEFFERED SUBMITTALS) STATE or WASHINGTON <br /> 18" <br /> TP HOLDER 0 HARDWIRED SMOKE/CO DETECTOR W/BATTERY BACK-UP <br /> BLOCKING 4!) EXHAUST FAN 0 DRYER VENT STAMPMIN. <br /> 3/4'(33'MIN. <br /> '�`/1 It WHOLE HOUSE FAN PER IMC REQUIREMENTS <br /> r/7 !�\TYPE'B'BATHR9Qm 6-'\TYPE'B'BATtR9OfA ;-\TYPE'B'BATIjR9O,M. TYPE'B'BATHROO)A POWER VENT WILL BE REQUIRED FOR DRYER $ <br /> 1/4"=1'-0' �OPTIO 1/4"=1'-0" OPTION B 1/4".1'-0" APTION B� 1/4"=1'-0" ',\OPTION B(� EXHAUST LENGTHS THAT EXCEED MANUFACTURER'S S i <br /> �- -•"N�� ® - i /1� �-��-- SPECIFICATIONS.SEE MECHANICAL. 8 a <br /> FILLER <br /> _ FILLER 36" 30" 36" 36" 24" FILLER 34" 24" 33" 12" ILLER a ____ INDICATES LOCATION OF EXHAUST DUCTING m <br /> 12� lil�� CD1 1111111MINIMMENMMFi FOR DUCTS WITHIN JOIST SPACE-SEE DETAIL I®- <br /> . 11.11■ m`o R�M SOFFIT SOFFIT VENT THROUGH ROOF tt 6TH FLOOR ru <br /> _ <br /> • Ells <br /> a� � ���7 t1ryl �� .I��� I 1 `E �T-T"EN.S ERMINA IO DROPPED SOFFIT 1��� <br /> K3 10. ALL EXHAUST VENT TERMINATIONS MUST BE 3 FEET CLEAR FROM ANY <br /> .'\ <br /> �r OPERABLE OPENING INTO THE BUILDING,AND 10 FEET CLEAR FROM <br /> ' .- ANY MECHANICAL AIR INTAKE.GANG TERMINATIONS TOGETHER UNDER <br /> • <br /> m� MMMMMMM� _r° ONE SHROUD,AS POSSIBLE. <br /> ��_ ' E— <br /> _ I. ..finial ���� " s <br /> FILE. 18" 30" 36" 38" 24" , ILLER 24' ,ink 33" I}FILLER 13. REQUIRED CLEAR FLOOR SPACES AS SHOWN ON PLANS'.REFER a y <br /> .�( ALSO TO ACCESSIBIUTY NOTES SHEETS A550. <br /> NZ, 30X48"CLR.FLOOR SPACE AT FIXTURES&APPUANCES 8 <br /> �� A/ (CENTERED)&ONE AREA FREE OF DOOR SWING IN BATH <br /> s \TYPE KITCHEN TYPE KITCHEN <br /> f----li 46X48"CLR.FLOOR SPACE AT ENTRY DOOR PUSH SIDE-ALL __ <br /> 1/4"=1'-0" 1/4"=1'-0" I UNITS $1i <br /> 54"X60"CLR.FLOOR SPACE AT PULL SIDE OF ALL PASSAGE $ <br /> 66-0" I.____,JJ DOORS-TYPE A UNIT ONLY <br /> 12 11-6 _ 2'-6" 9'-2" 6-6" 7-4" 5-0' 10'-4" / 14'-0" "` <br /> ,ram'-'`'-'-'- <br /> TOWEL BAR 2 'VERIFY' 60'MANEUVERING CIRCLE-TYPE A UNITS ONLY <br /> • 71 7C BLOCKING j -__ • ° <br /> \ ` , •_L ♦- _1 \ I L s O \ \ 14. CONTROLS,FAN WALL SWITCH&OUTLETS TO BE WITHIN REAC m <br /> --T�-- ' a - \_ / RANGES-SEE ACCESSIBILITY NOTES SHEET A5508 DETAIL VW g <br /> 3 LL--. �„ co t8"- REF. i- <br /> -' D W _ - I 6 m 15. FOR TUBS AT FIRE-RATED WALL AND FLOOR ASSEMBLIES-SEE®® <br /> n ''' O• la Ls 0: 1 M.BATH <br /> En + r 2 <br /> IN -'i /�� \ Fa 18. ELECTRICAL PANEL m S <br /> /. I_A 4� ��� i 1 4'1 � z A150 9 17. S+p=SHELF&POLE.CLOSET SHELF&POLE IN TYPE AUNITS TO BE H �' <br /> �� B ��-'t1 �� A 5 ��•(( --'KITCHEN,p <br /> 3 _ I�, ADJUSTABLE TO BE WITHIN REACH RANGE 48"MAX_AFF. 44 <br /> o. <br /> BEDROOM 2'-10' 7 LYJ RA BSI' — \ 'N C <br /> VERIFY -'H - - LAUNDRY I1___,) •__ w :___) 0 $ <br /> _phTrI ` � U7A 'I t �aG N O O .CLOSET 5 UNIT INTERIOR ELEVATION NOTES h <br /> _ 1CIS 19 <br /> � <br /> •� V�``1 �� 1. DIMENSIONS ARE TO FACE OF G.W.B(NET),UNLESS NOTED OTHERWISE <br /> 4 "t'+ 2. FIELD VERIFY ALL FINISHED DIMENSION PRIOR TO ORDERING CABINETS Q 3 of 3 <br /> a 1' i�-• CARPETX VINYL tii 41 AND COUNTERTOPS. �R <br /> y� SW 3. PROVIDE BLOCKING AT TOILET PAPER HOLDERS.TOWEL BARS,DOOR O 0 8 o, aal <br /> 0 0 0 - F w STRIKES,DRAPERIES,REMOVABLE CABINET SUPPORTS&GRAB BARS. L 3 0 <br /> G > i 4 TYPICAL CABINET SYSTEM PROFILE,SEE DETAIL 0 $ a <br /> g <br /> �— a 4° r ""^� ���� �� 4 g 6 -`-/- KITCHEN KEYNOTES BATH KEYNOTES i z e t< <br /> z 0 a� ,,_.,_._,_. ram- -,,,,T 0 .. _ 0 <br /> U aUN E <br /> k Na 2 EXHAUST,SEE UNIT PLANS FOR <br /> / w U ;�' <br /> Sop SOP g (DJ® <br /> I q I� Kt b1 ACCESSIBLE LAY.SINK AND �. � y w Ja <br /> `L II S+P -'`J UNITS SEETYPEABB v rc a <br /> 0 EXTENT OF DROPPED SOFFIT. 3 o 11= 51 W <br /> O all 0 �6 = _ b2 OPEN KNEE SPACE FOR G i aG <br /> Z m l l ry CABINETS W/ADJUSTABLE SHELVES VANITY SINK AT ALL m 0 C 3 <br /> A II/1 0 O� PER FINISH SCHEDULE. ACCESSIBLE BATHROOMS IN IL m O I°� m <br /> m = 7--, L 5'-5" COUNTERTOP&BACKSPLASH PER TYPE A UNITS.EXTEND M16 <br /> 9'-8' 2'-8' 9'-8" 10-4^ 20'-0" 14'-0" K3 FLOORING UNDER-SEE <br /> ("I / _ / / I-t a OWNER SPECIFICATIONS. b3 PROVIDE GRAB BARS <br /> JL O ADAPTABLE FEATURE FOR <br /> SI BEDROOM j r l' BEDROOM 3 BEDROOM 4 A LEJ�¢ AMEM A TYPE B LEU WS,AND LOSET <br /> 0 o a_ - A m ADA COMPLIANT FAUCET W/LEVER INSTALL GRAB BAR @ TYPE O <br /> m O HANDLE(ALL UNITS) A UNITS-SEE <br /> C Li-- in ID '—I O PROVIDE GRAB BARS 5 <br /> LL 7 A '- REMOVABLE CABINET(ADAPTABLE <br /> IN Co 0/ Q O FEATURE)Q OPEN KNEE SPACE FOR ADAPTABLE FEATURE FOR e <br /> _ 00 3'-9' SINK AND ANALOWEREDF TO WMKSPACE® SHOWER TUB Q TYPE B <br /> UNITS AND INSTALL GRAB O <br /> �' KNEESPACE-EXTEND FLOORING BAR 0 TYPE A UNITS-SEE <br /> A D MIN <br /> B UNDER MIRROR-40'A.F.F.MAX TO <br /> \ X II OB B II--'--14�1 O2 I I(� (TYPE A ACCESSIBLE UNITS ONLY) O BOTTOM EDGE OF <br /> 2'-71/Y� 1 J" 4 OB \ B 4 BO „ 1 m i W I n OB F 11 ` \ O BILCINDO CORNEER CABINET O REFLECTING SURFACE. <br /> / lr I SURFACE MOUNTED LIGHT PROJECT p, 1827 <br /> a Ta u 2gCK 5'-613118"�' O SPECIFICATIONHOOD PER OWNER O BAR DRAWN BY, AT <br /> 4 / 4'-111/4' 7A , 4'-112' 3'-3' 7'-0" b7 TUB&SURROUND PER <br /> 4_ 4_ OL C K9 RANGE WI FRONT CONTROLS OWNER SPECIFICATION. CHECKED BY: ST <br /> �b.... O (TYPE A ACCESSIBLE UNITS ONLY) O WIRE SHELVING <br /> P.T. RANGE 0L PLASTIC 5 BEDROOM PLAN& <br /> U 170' 20-0" 20-0' i ®i CHAT46'MAX.AFF..PROVIDE O LAMINATECOUNTERTOP& ELEVATIONS(TYPE <br /> B) <br /> / ` / / / — <br /> / COUNTERTOP MICROWAVE(TYPEA <br /> BACKSPLA PER OWNER <br /> _ 65-0' ACCESSIBLE UNITS ONLY) SPECIFICATION. <br /> A501 V°O°O / Q. 'ADA COMPLIANT'REFRIGERATOR 0 VANITY SPECIFICATION.TS OWNER Al 5 0 <br /> " w --MAX,--„54'"HT.AFF TOFr FREEZER <br /> 1 MIN.20 CA.STAINLESS STEEL <br /> �,5 BEDROOM UNIT-TYPE B(OPTION B BATH). -V®KITCHEN SINK CONSTRUCTION SET <br /> LL UNIT s 2 09/01/2021 <br />