My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY 2022 EVERETT 4 CORNERS - BLDG B Plans 2025-07-02
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG B
>
Plans
>
8102 EVERGREEN WAY 2022 EVERETT 4 CORNERS - BLDG B Plans 2025-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 10:43:17 AM
Creation date
7/2/2025 10:42:23 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG B
Permit
M2206-006
Year
2022
Notes
BUILDING B UNIT VENTILATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHEET NOTES MIIMI <br /> 1. LEVELS 2-6 TYPE VA CONSTRUCTION <br /> Co R2 OCCUPANCIES <br /> 2. ALL LEVELS FULLYSPRINKLERED PER JOHNSON BRAUND.c <br /> IBC SECTION 903.3.1.1(NFPA 13). 15200 52nd Ave.South <br /> Suite 300 <br /> 3 REFER TO SHEETS CS03 FOR FIRE Seattle,WA 98188 <br /> ASSEMBLY KEY PLAN W/WALL TYPE Phone 206.766.8300 <br /> TAGS&LOCATIONS.REFER TO wwwpMsoaeraund corn <br /> SHEET SERIES A040 FOR ASSEMBLY ARCHITECTURE <br /> DETAILS. INTERIOR DESIGN <br /> 4. SEE ENLARGED UNIT PLANS FOR ALL Greg I.AIAWne. <br /> INTERIOR DIMENSIONS,WINDOW AND Jeffrey A Wd'iams. <br /> DOOR CALL-OUTS,AND RATED WALL <br /> TAGS <br /> 5 EXIT STAIR ENCLOSURES IN TYPE 1A <br /> CONSTRUCTION SHALL BE 3-HOUR <br /> RATED <br /> 6• <br /> ALL VERTICAL SHAFTS SHALL BE 2- <br /> HOUR RATED PER BC SECTION 713.4. <br /> 7 O DOOR SHEET A100 SEE SCHEDULE <br /> I <br /> A321 6 REFER TO SHEET SERIES UNIT PLAN DOOR 8 WINDOWS FOR <br /> B.b B. ^ REGISTERED <br /> 1 B.d B.e CDB.g <br /> SCHEDULE. 1\/ ARCHITECT <br /> 65•"y" <br /> 9. REFER TO SHEETS A710,A120, <br /> 12'-2" 1T-10" 5•-4" 1T-10" yy 12'-2" 2'-0" A130,A140,A7508 A151 FOR F'FRF:y ARTFII'S SILLI. <br /> I - 1 'I ENLARGED UNR PLANS. STATE OF wASRwGTOR <br /> r� m ( 10. REFER TO ACCESSIBILITY NOTES UAW <br /> CD1.-I . _ _ B 7 ON SHEET CS00 <br /> I11. PROVIDE MECHANICALLY '1 <br /> Y4 <br /> IF <br /> II 41 I !till m FASTENED INSULATION AT ALLit- -TO- E a CEILINGSB RIONED CONDITIONED • 1 si <br /> m I I REFER TO SHEET A040 FOR ' <br /> REQUIRED R-VALUES. <br /> Pigli <br /> _ 12. CORRIDOR VENTILATION CONCEPT w <br /> .1 <br /> 1. A. 11.0_1w ,,, SHOWN,REFER TO DESIGNBUILD <br /> 11 1eII MECHANICAL PLANS. <br /> I I� iN <br /> L I I F.., RECESSED FIR EXTINGUISHER <br /> •' . _ t3. -»a- CABINET <br /> SEE DETAIL 6m I �) Ill <br /> aii�J I A�1u I 7A 14 .F.E. SURFACE MOUNTED FIRE ,I I EXTINGUISHER CABINET n:o LOCATE PER IBC TABLE 906.3'ti LL1:1 NV i <br /> II it <br /> II PIARKING MGARAGE LEVELAX OONLY <br /> SEE III <br /> I ir - 1 HEIGHT <br /> 3/A051 FOR <br /> MOUNTING/INSTALLATION <br /> I <br /> 15. IEXRI SIGN PER IBC SECTION 1013 <br /> �I � I <br /> eII 327 ' ' -—- 328 I --_I I 16. REFER TO DESIGN/BUILD— --SHEET A1401--- —-SHEET A140--—-— ELECTRICAL PLANS. <br /> Al I <br /> m I I <br /> 17. REFER TO SHEET A051 FOR - <br /> ,��, PENETRATION REQUIREMENTS IN <br /> g III <br /> I 9 FIRE RATED CONSTRUCTION. <br /> ler% <br /> II IM{'Ql�.-.-m 'm' �I� �� 18. VELOPE <br /> DRAWINGS FOR ALL WAREFERENCE BUILDING TERPROOFING. G <br /> ry rr*i g. <br /> E. S '1 '1 Ai '• IIaII <br /> El I 19 INDICATES TVPE AACCESSIBLE UNIT. 1 <br /> ® LL ALL REMISING UNITS SHALL MEET TYPE <br /> ALLR E SIBLEWING UNIT SHALL MEETTS <br /> c I 1� (• PER IBC SECTION 1107.6.2 'bwF ,i' P ) _AD 20. UNIT DEMISING WALLS ARE 1 HOUR i. <br /> A <br /> �I �- ON 708 W/ <br /> I'� i <br /> ' M1 IMUM STC 50.SEERATED PER IBC ISHEETS A0408A041NI .____—cORitlDaR-SHA J Lum II0g <br /> " I II - 21. �/;1 INDICATES TYPE'A'UNIT <br /> i DIW v <br /> t II 22. AT DOORS INTO ELECTRICAL CONTROL I. <br /> ,) �� ____ tl PANEL ROOMS,SIGNAGE SHALL BE R <br /> l_z-o <br /> �Ji - PROVIDED ON THE DOOR STATING <br /> 1 J 1 _ 'ELECTRICAL ROOM' IC EW <br /> 1111 <br /> .7 G= " 23' ATDOORSINTOFIRE PROTECTION <br /> aIv EQUIPMENT ROOMS CONTAININGQ3 I I NIT3I III - SUPPRSPRINESIONISERS.FACP,CONTROL ELEMENTS. <br /> EN SER tJ €a <br /> I 326 <br /> UNIT 3.1 m SHEET At30 APPROVED SIGNAGE SHALL BE L 3 0 <br /> PROVIDED AND READILY VISIBLE PER - 8 O <br /> SHEET A1301 IFC SECTION 509.1 = go <br /> L z <br /> r N a3 <br /> C '� 9 24 SYSTEM PER IBC SECTION 1'009.8 0 "W U N 3 <br /> I 3 <br /> v. <br /> 1."0. I4."o. r__= I N 7 E a?z3 1, <br /> I yyi [ 0 3om wa <br /> b I L I_•..:.Ju re Ls: . - II II LL y O LL�m .a <br /> II ILL 1� <br /> A322 1 _t I �,'�. --II <br /> ' C7 A323 <br /> r-o <br /> II <br /> I I el <br /> U ©' ul 11 <br /> 0: 1 KEY PLAN <br /> t -co <br /> • m �m I �M_ tl I -. <br /> E I I I I I I <br /> I PROJECT A1827 <br /> 2 <br /> I <br /> DRAWN BY AT <br /> B.b 0 0/ CD 0 0 <br /> CHECKED BY: ST <br /> j ® ® BLDG <br /> NORT FLOOR 3 <br /> ti <br /> BUILDING B <br /> ai <br /> A222C <br /> i (1 BLDG B-LEVEL 3 NORTH CONSTRUCTION SET <br /> �. —_- ve"=-r-o"- --- -- 09/01/2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.