My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY 2022 EVERETT 4 CORNERS - BLDG B Plans 2025-07-02
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG B
>
Plans
>
8102 EVERGREEN WAY 2022 EVERETT 4 CORNERS - BLDG B Plans 2025-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 10:43:17 AM
Creation date
7/2/2025 10:42:23 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG B
Permit
M2206-006
Year
2022
Notes
BUILDING B UNIT VENTILATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i SHEET NOTES <br /> 1. LEVELS 2-6 TYPE VA CONSTRUCTION 4> <br /> R2 OCCUPANCIES JOHNSON BRAUND'n, <br /> 2. ALL LEVELS FULLY SPRINKLERED PER 15200 52nd Ave.SouthIBC SECTION 903.3.1.1(NFPA 13). Soee 300 <br /> 3 REFER TO SHEETS CS03 FOR FIRE Seattle,WA98188 <br /> ASSEMBLY KEY PLAN W/WALL TYPE Phone 206.766.8300 <br /> TAGS&LOCATIONS.REFER TO 3,3w.pnnsonbxvn4 Coro <br /> SHEET SERIES A040 FOR ASSEMBLY ARCHITECTURE <br /> DETAILS. INTERIOR DESIGN <br /> a. SEE ENLARGED UNIT PLANS FOR ALL Greg L AINAne, <br /> INTERIOR DIMENSIONS.WINDOW AND Jeffrey A W6e,vs. <br /> DOOR CALL-OUTS,AND RATED WALL <br /> TAGS <br /> 5 EXIT STAIR ENCLOSURES IN TYPE 1A <br /> CONSTRUCTION SHALL BE 3-HOUR <br /> RATED <br /> ALL VERTICAL SHAFTS SHALL BE 2- <br /> 6. HOUR RATED PER IBC SECTION 713.4. <br /> O DOOR TYPE-SEE SCHEDULE <br /> I SHEET A100 <br /> I I 8. REFER TO SHEET SERIES A100 FOR 8556 <br /> A321 I UNIT PLAN DOOR&WINDOW REGISTERED <br /> B.b I B.c 1 B.e B.f B.g <br /> SCHEDULE. I RCHITECT <br /> 6s_s^ <br /> _ • I 9. REFER TO SHEETS Al10,A120, <br /> T-0" 12'-2" I iT-10" 5'-4" ' 17'-10" I. 12'-Y 2'-0" A130,A140,A150&A151 FOR FFHF.',1NTII1'R vrILUAlI <br /> +� ENLARGED UNR PLANS. STATE Or WASHINGTON <br /> B.1 —■r- ir.__,.____ _ <br /> 6.1 10 ONFSHEET CSOOSSIBILITV NOTES sv+ev <br /> I <br /> + - 117111 11. PROVIDE MECHANICALLY <br /> 1 FASTENED INSULATION AT ALL t <br /> I (� I S let �l II CEILINGS BETWEEN CONDITIONED 6 <br /> m I AND UNCONDITIONED SPACE, K&' <br /> REFER TO SHEET A040 FOR <br /> REQUIRED R-VALUES. <br /> I I O ,'�� O I 12. CORRIDOR <br /> SHOWN,REFER TOI DESIGN/BUILD <br /> t0 g <br /> II L' '�h I ]' �" Ill MECHANICAL PLANS. <br /> L ( 13 F.EC RECESSED FIRE EXTINGUISHER <br /> I !, I JEu1 <br /> + SABINETSEE DETAILm �� V I I •F.E. SURFACEMOUNTEDFIRE 2. <br /> t't ' i I ,J 1 14. EXTINGUISHER CABINET o <br /> II III 7: ___'ILL I ' LOCATE PER IBC TABLE 906.3 g <br /> 1 II _ - II 8EE DETAILIGARAAGE LEVEL OONLY ,`q <br /> 1 IIIII <br /> R • 1 I I I 051 FOR <br /> A II 1 HEIGHTING/INSTALLATION <br /> 15. I EXIT] SIGN PER BC SECTION 1013. 1 <br /> NU IIf 4.1 I UNIT 4.1 _ <br /> �1n�f� 16. REFER TO DESIGN/BUILD <br /> 2 427 "'� I� 428 I I' ELECTRICAL PLANS. <br /> P <br /> _---SHEETA740 ——— —LSHEETA140———-- ------' 17. REFERTOSHEETA051 FOR <br /> PENETRATIONREQUIREMENTSIN <br /> I m I I I J FIRE RATED CONSTRUCTION. <br /> y�ff] i frZl f <br /> 18. REFERENCE BUILDING ENVELOPE <br /> _ _ DRAWINGS FOR ALL WATERPROOFING. 1-2 <br /> En III IIII ' 181ie II I INDICATES TYPEAACCESSIBLE UDR. o <br /> ST IRN2 ,N Air, <br /> � II, 7D 19. ALL REMINING UNITS SHALL MEET TYPE <br /> ST 2 1 �I B ACCESSIBLE UNIT REQUIREMENTS <br /> o A �■ I M I I , I PER INC SECTION 1107.6.2 N <br /> '� I 20 UNIT DEMISING WALLS ARE 1 HOUR <br /> _ _ RATED PER INC SECTION 708 W/ <br /> ■ II 17G �� S� ,407 -- Ti MINIMUM STC 50.SEE SHEETS A040&A041 y w <br /> °j I - .---.—COTtRIXWSRAF 1 i 1,.-.. I - 4r <br /> El I 3 <br /> I, - fill <br /> �❑ All ' II 21.® INDICATES TYPE'A'UNR �� H$II I 1 1 22. AT DOORS INTO ELECTRICAL CONTROL 4 <br /> _ _Ng ---a 0 1 I PANEL ROOMS,SIGNAGE SHALL BE L <br /> 2'-0" 1 l PROVIDED ON THE DOOR STATINGIIIIS C Q <br /> I` �� el 'ELECTRICAL ROOM' fO SE <br /> y�G=�m 23- AT DOORS INTO FIRE PROTECTION �. <br /> I u rt 3 I <br /> p EQUIPMENT ROOMS CONTAINING a 3 0 'm <br /> I I 428 SUPPRESIONSPRINKLER ICONTROL ELE ENS.SERS,FACP,OR co S '§ <br /> _ 6 II I UN 3.1 FA m I SHEET A730 APPROVED SIGNAGE SHALL BE 13 0I IFC SIDCTON 509.1 ADILV VISIBLE PER w. g go <br /> II SHEET A130 24. w TTWO-WAY COMMUNICATION w �a )N$ a3= SYSTEM PER IBC SECTION 1009.8 //0� rn L1�N I k <br /> 1 Q <br /> Z, .. . ,m I I 1 I W D Iti. — l - C 3Ui. II.11 <br /> , d. <br /> I I ILL' �� U. rn OLL-m Se <br /> � 23 <br /> I A322> I �l DPI f ^, <br /> • T.D. I - , i <br /> U I El <br /> KEY PLAN <br /> co <br /> El ~m IlllJI el I l -_, <br /> I <br /> § I I I I I I I <br /> O 9 irk <br /> 1 PROJECT II: 1827 <br /> 21 <br /> 0 ®B.c 0 �T 0 0DRAWN BY: AT <br /> CHECKED BY: ST <br /> �_ <br /> [ 7:-1--1 <br /> BLDG B-FLOOR 4 <br /> L.) NORTH <br /> w <br /> ai BUILDING 8 A223C <br /> 0 = ,, .- a/ ,,.;;41, CONSTRUCTION SET <br /> IC 1/8"=1-0" V 09/01/2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.