My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY 2022 EVERETT 4 CORNERS - BLDG B Plans 2025-07-02
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG B
>
Plans
>
8102 EVERGREEN WAY 2022 EVERETT 4 CORNERS - BLDG B Plans 2025-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 10:43:17 AM
Creation date
7/2/2025 10:42:23 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG B
Permit
M2206-006
Year
2022
Notes
BUILDING B UNIT VENTILATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHEET NOTES <br /> kei <br /> `A 1. LEVELS 2-8 TYPE VA CONSTRUCTION 4> <br /> R2 OCCUPANCIES <br /> 2. ALL LEVELS FULLY SPRINKLERED PER JOHNSON BRAUND <br /> IBC SECTION 903.3.1.1(NFPA 13). 1520052nd Ave.South <br /> Suite 300 <br /> 3 REFER TO SHEETS CS03 FOR FIRE Seattle.WA 98108 • <br /> ASSEMBLY KEY PLAN W/WALL TYPE Phone 206.766.8300 1 <br /> TAGS&LOCATIONS.REFER TO eww.MhneenMawM COI" <br /> SHEET SERIES A040 FOR ASSEMBLY ARCHITECTURE <br /> DETAILS. INTERIOR DESIGN <br /> 4 SEE ENLARGED UNIT PLANS FOR ALL Greg L Allwine. <br /> INTERIOR DIMENSIONS,WINDOW AND Jeffrey A wniams. <br /> DOOR CALL-OUTS,AND RATED WALL <br /> TAGS <br /> 5 EXIT STAIR ENCLOSURES IN TYPE TA <br /> CONSTRUCTION SHALL BE 3-HOUR <br /> RATED <br /> 6 ALL VERTICAL SHAFTS SHALL BE 2- <br /> HOUR RATED PER IBC SECTION 713.4. <br /> 7. ODOOR TYPE-SEE SCHEDULE <br /> SHEET A100 <br /> -. I A321 1 8. REFER TO SHEET SERIES A100 FOR 8556 <br /> UNIT PLAN DOOR&WINDOW \ REGISTERED <br /> B.b CI <br /> Bd B.B I B.f B.g SCHEDULE. ARCHITECT <br /> 9. REFERT0,A150 SHEETS FFRr1 ARTRI,e WILLIAM <br /> 21" 12'-2' 17'-10• 5'-4" 1T-10' 12'-2" 2'-0" A130,A140,A1508 A1S1 FOR STATE or wA6RIRc1oR <br /> I ENLARGED UNIT PLANS. <br /> _ _ I 10. REFER TO ACCESSIBILITY NOTESgee.ir . ' - _-— \ i B.1 ON SHEET CS00 <br /> L . I;I <br /> m 11 FASTENED INSULATION AT ALL Q <br /> CEILINGS BETWEEN CONDITIONED <br /> LLY <br /> S-�I - <br /> AND UNCONDITIONED SPACE, S <br /> REFER TO SHEET A040 FOR <br /> REQUIRED R-VALUES. <br /> 1__ F1 I ^ "_ - _ 12. CORRIDOR VENTILATION CONCEPT wS_ <br /> I I sae 1 I <br /> � 21 3 I SHOWN,REFER TO DESIGN/BUILD <br /> 61 <br /> MECHANICAL PLANS. <br /> 13. F.E.C. CABINE ED/FIRE EXTINGUISHER <br /> CABINET 8 <br /> II el I I.I. , SEE DETAIL: <br /> N a � A051 <br /> m (� ,JSURFACE w I m m 14. F.E. EXTINGUISHER NCABINET E x <br /> ' I` II — LOCATE PER IBC TABLE 906.3 <br /> _ II II r Ili",— , II tl PARKING GARAGE LEVEL ONLY 75 FT.MAX.SEPARATION- $w <br /> II II II II _ SEE DETAIL 3/A051 FOR <br /> II II II II MOUNTING/INSTALLATION <br /> ---- II I -,- ,i I 11 II <br /> I-2— m HEIGHT i <br /> 15. IEXITI SIGN PER IBC SECTION 1013 1 <br /> 8• © yId.1 IUNIT. I - 16. REFER TO ICALEP DESIGN/BUILD m 1 <br /> ELECT® _ "1111 SHEET A1401-- -ill 1 m_ ___— SHEET A140—_ _— I—_ ' <br /> 17. REFER TO SHEET A051 FOR ¢- <br /> I , PENETRATION REQUIREMENTS IN <br /> m I FIRE RATED CONSTRUCTION. F <br /> R �' I m — f -^B 18. REFERENCE BUILDING ENVELOPE <br /> i N DRAWINGS FOR ALL WATERPROOFING. <br /> I le I• II INDICATES TYPE A ACCESSIBLE UNIT. E <br /> M 4 „'aN ©t _ II ©' 19' ALL REMINING UNITS SHALL MEET TYPE <br /> ST•R#2 _ u LL B ACCESSIBLE UNIT REQUIREMENTS <br /> m A I'I P 7J �� PER INC SECTION 1107.6.2 g <br /> • Ni _I 1 Ti Ar® ' 20 UNIT DEMISING WALLS ARE 1 HOURkr 1 <br /> I --- Ij <br /> RATED PER MI IMUM STCC SESEE CTIOON 708 AD408A047 (() �'CORRIDOR SHAFT illi O 31 <br /> 21. 0 INDICATES TYPE'A'UNIT C 3 <br /> ii <br /> — D7W E 6�a <br /> ��� — Y 1 o m 22. AT DOORSELECTRICALCLBEROL <br /> , , <br /> 1 PANEL ROOMS,SIGNAGE SHALL BE <br /> •) = PROVIDED ON THE DOOR STATING <br /> T `._ ( ELECTRICAL ROOM' iV <br /> p— J ~• �' 23, AT DOORS INTO FIRE PROTECTION T g3 <br /> EQUIPMENT ROOMS CONTAINING Q 3 m $ <br /> a SUPPRESIONICONTROLELEMENTS, M 1 <br /> _ I <br /> b, UNIF 3.1 u� m SHEET A130 <br /> • APPROVED SIGNAGE SHALL BE L 0 a ° <br /> , PROVIDED AND READILY VISIBLE PER 8 <br /> E25 ry IFC SECTION 609.1 ` S Fa <br /> SHEET A130 <br /> 24. TWO-WAY COMMUNICATION ;To II z <br /> _ ! ,� \ SYSTEM PER IBC SECTION 1009.8 0 m U J N 90 <br /> LIMIIILOW 1 w y ;rc <br /> • <br /> MI 1 0") 4,0", II Y =___ <� - 3 aUim EG <br /> ml To II 1 W D I IW 1• - 1 LL m o1.-m Va <br /> 1 - 1" a <br /> m \ ILL �1 it / <br /> O A322 J _ C_P 1 0�I `1 A323 <br /> EI / Olin \ \ \ <br /> m I 1~�I= I I f�,. A <br /> o 2-a�" 1 I �� m C. <br /> ® Q)o I N KEY PLAN <br /> III I <br /> r. I lab. — <br /> 1 1 <br /> co \`N 441 1 • <br /> _ . <br /> 7A tm _ ( i <br /> E I I I I I <br /> PROJECT 8: 1827 <br /> DRAWN BY' AT <br /> dD <br /> 0 0 0 La 0 0 <br /> m CHECKED BY. ST <br /> ti <br /> ® ® BLD NORTHFLOOR 5 <br /> • 1 ^ BUILDING B A2 24 C <br /> 1 BLDG B-LEVEL 5 NORTHAMEMOmmmidEMMI <br /> /� \, CONSTRUCTION SET <br /> - LL -- -- i:�-_1.o., `� r/ 09/01/2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.