Laserfiche WebLink
GENERAL UNIT PLAN NOTES iMii <br /> Iii <br /> S 1 LEVELS 241:TYPE V-A 4> <br /> ALL LEVELS FULLY SPRINKLERED PER NFPA 13. <br /> 2 SEE SHEETS AO/0-A041 FOR FIRE-RESISTIVE ASSEMBLY TYPES JOHNSON BRAUNDSI <br /> TYPICAL WALL TYPES. 1520052nd Ave.South <br /> LEVELS 2 TO 6-TYPE V-A CONSTRUCTION Suite 300 <br /> Seattle,WA 98188 <br /> -7C CORRIDOR WALL Phone 206.766.8300 <br /> 7A EXTERIOR WALL 00.Ichnsonbmundoom <br /> ARCHITECTURE <br /> -7D UNIT DEMISING WALLS INTERIOR DESIGN <br /> 76 INTERIOR WALL(NON-LOAD BEARING) Greg L.Annna. <br /> Jeffrey A.651/ams, <br /> B1 INTERIOR WALL(LOAD BEARING) <br /> 3. REFER TO OWNER PROVIDED FINISH&FIXTURE SCHEDULES. <br /> 4. OX DOOR TYPE-SEE DOOR SCHEDULE ON SHEET A100 <br /> 5. O WINDOW TYPE-SEE UNIT WINDOW SCHEDULE ON SHEET A100 <br /> 6. ALL UNITS ON AN ACCESSIBLE STORY SHALL COMPLY WITH WASHINGTON STATE <br /> (CC/ANSI 117.1)"TYPE B"_SEE FLOOR PLANS FOR LOCATIONS. <br /> FIVE PERCENT OF TOTAL NUMBER OF UNITS ARE DESIGNATED AS'TYPE A"UNITS <br /> SEE SHEET A020 FOR TYPE A CALCULATION.SEE FLOOR PLANS FOR LOCATIONS 8556 <br /> SEE UNIT SHEETS FOR TYPE A"AND"TYPE B"UNIT PLANS. \ <br /> REGISTERED <br /> SEE ACCESSIBILITY NOTES SHEET A550 ARCHITECT <br /> SEE SHEET A550 FOR ACCESSIBLE DETAILS <br /> 7 REFER TO SEPARATE ELECTRICAL&MECHANICAL DRAWINGS MEN Affix I'a viimuv <br /> STATE Of WASHINGTON <br /> (DEFFERED SUBMITTALS) <br /> Q HARDWIRED SMOKE/CO DETECTOR W/BATTERY BACK-UP STAMP <br /> C EXHAUST FAN 0 DRYER VENT <br /> ® WHOLE HOUSE FAN g <br /> PER IMC REQUIREMENTS <br /> POWER VENT WILL BE REQUIRED FOR DRYER 4 z <br /> EXHAUST LENGTHS THAT EXCEED MANUFACTURERS B <br /> SPECIFICATIONS.SEE MECHANICAL 8 a <br /> • <br /> 6 _ __ INDICATES LOCATION OF EXHAUST DUCTING m <br /> FOR DUCTS WITHIN JOIST SPACE-SEE DETAIL <br /> VENT THROUGH ROOF IS 6TH FLOOR al <br /> 9. .. INDICATES LOCATION OF DROPPED SOFFIT <br /> 6 T-0"MIN.SEE DETAIL IWY <br /> 10. ALL EXHAUST VENT TERMINATIONS MUST BE 3 FEET CLEAR FROM ANY <br /> OPERABLE OPENING INTO THE BUILDING,AND 10 FEET CLEAR FROM <br /> ANY MECHANICAL AIR INTAKE.GANG TERMINATIONS TOGETHER UNDER <br /> ONE SHROUD,AS POSSIBLE. <br /> 8 <br /> 13. REQUIRED CLEAR FLOOR SPACES AS SHOWN ON PLANS:REFER . <br /> ALSO TO ACCESSIBILITY NOTES SHEETS A550. i 0 <br /> 30'X48"CLR.FLOOR SPACE AT FIXTURES&APPLIANCES 8? <br /> (CENTERED)&ONE AREA FREE OF DOOR SWING IN BATH - <br /> 98 <br /> T----1 1 48'X48"CLR.FLOOR SPACE AT ENTRY DOOR PUSH SIDE-ALL -- <br /> UNITS 1 i @ <br /> I 54'X50'CLR.FLOOR SPACE AT PULL SIDE OF ALL PASSAGE O E 8 <br /> L____JJ DOORS-TYPE A UNIT ONLY <br /> / 38'-0" 60'MANEUVERING CIRCLE-TYPE A UNITS ONLY <br /> r 10'-0' 5'-0' / 11'-6" / 11'-2" 4 ` <br /> OWEL BAR 2 ❑ er <br /> � f— ❑ TOWEL BAR BLOCKING <br /> BLOCKING <br /> 11 14. CONTROLS,FAN WALL SWITCH&OUTLETS TO BE WITHIN REAL m o <br /> \ \ ��,,,�,� \ I ,I \ \- �.5 \.\-- d�� RANGES-SEE ACCESSIBILITY NOTES SHEET AS50&DETAIL v <br /> 15 1 VERIFY REF. ..], I I 8 �� 15. FOR TUBS AT FIRE-RATED WALL AND FLOOR ASSEMBLIES-SEE®® <br /> �� A120\ 8 S - 1 h 3 O o 16. ELECTRICAL PANEL m $ <br /> / n , iJ 2 N 17. S.P=SHELF&POLE.CLOSET SHELF&POLE INT'PEA UNITS TOBE N S <br /> r- 7 -A __ y,'I� ADJUSTABLE TO BE WITHIN REACH RANGE 48"MAX.AFF. 4+ w <br /> 0. <br /> 'v_I ` C ; <br /> n BATH 1 I O .13DrcHEr O 5 M.eATH 1 CD $ <br /> Sep <br /> 4 \ S 4 \ � n\�\\ >a <br /> �2" -1' ' _ _ _ 17 <br /> � I s S'P ry 4 - — \ !� UNIT INTERIOR ELEVATION NOTES Y <br /> n \ al <br /> � y2 2'-10' '-10" \ S L \ �L� 1. DIMENSIONS ARE TO FACE OF G.W.B(NET),UNLESS NOTED OTHERWISE. <br /> ire <br /> 11 <br /> A /III� ig <br /> � / / c� M.CLOSET " 2. FIELD VERIFY ALL FINISHED DIMENSION PRIOR TO ORDERING CABINETS Q 3 0 gi <br /> O tl AND COUNTERTOPS. <br /> \ 3. PROVIDE BLOCKING AT TOILET PAPER HOLDERS,TOWEL BARS,DOOR N g m �§ <br /> ,I'J 4 5' L I 7 N 21/4 n STRIKES,DRAPERIES,REMOVABLE CABINET SUPPORTS&GRAB BARS. 589 L D. Sg <br /> w _ r''-'r- ' > I p 4. TYPICAL CABINET SYSTEM PROFILE,SEE DETAIL $ u <br /> e _ ' _e \ \ 1 1 I I1 ; C N� V r <br /> r 4 -- -2'-5"-I a --- [_,,_ \\\\\\�e� KITCHEN KEYNOTES BATH KEYNOTES 1. -. Z g< <br /> a b e� �� �1 g RANGE m '.71 6 Si ¢C <br /> e A a1��;{;1H, I' <br /> .o ! _- >A m 'i i .�' .�'/-J K7 EXHAUST,SEE UNIT PLANS FORD D1 v ill y <br /> 4 -� - co 0 2'-7 B" 1'-61/4" ACCESSIBLE LAY.SINK AND <br /> �/ �l1e a TCOUNTER-TYPE ABB L o Q m�� ;W <br /> �� F-Il !G EXTENT OF DROPPED SOFFIT. UNITS-SEE 0 a o w - a <br /> WI yI O OPEN KNEE SPACE FOR m 0 Q 3o z W <br /> ZI , 1'- C. <br /> K2 CABINETS W/ADJUSTABLE SHELVES aw <br /> y O PER FINISH SCHEDULE. VANITY SINK AT ALL 3$m 53 <br /> c a 7 COUNTERTOP&BACKSPLASH PER ACCESSIBLE BATHROOMS IN 0 U. rn O m 4 f <br /> TYPE A UNITS.EXTEND <br /> 4) O OWNER SPECIFICATIONS. FLOORING UNDER-SEE 9 <br /> PROVIDE GRAB BARS <br /> 0I 0 &-6" MASTER O ADAPTABLE FEATURE FOR <br /> 1D 4 r 7C y ACCESSIBLE <br /> TYPE I UNITS,AND WATERCLOSET <br /> E LMNG w�'\\\\\\ ADA COMPLIANT FAUCET W/LEVER INSTALL GRAB BAR Q TYPE O <br /> 0 2 V4"-� O ( A UNITS-SEE <br /> 7D HANDLE ALL UNITS) O PROVIDE GRAB BARS 5 <br /> LL BEDROOM 1 '__ WOOD HATCH INDICATES 2HR \\ ELEV KB <br /> _ -'\ REMOVABLE CABINET ADAPTABLE ADAPTABLE FEATURE FOR A55p <br /> N ELEVATOR ENCLOSURE \ O SINK AND)OOEREKNEESPACE FOR UNITS AND INSTALL GRAB <br /> `Ylv p T SINK AND LOWERED WORKSPACE SHOWER OR TUB TYPE B <br /> w03 ., WALL-NO PLUMBING \ 34"MAX.AFF TO SINK RIM/2T'MIN O <br /> PENETRATIONS U4"MAX.CE-EX TEND FLOORING MIR OR-4DAUNITS-SEE <br /> 1B O E O \ UNDER b5 MIRROR-40'A.F.F.MAX TO <br /> (TYPE A ACCESSIBLE UNITS ONLr) O BOTTOM EDGE OF <br /> ;1 \ fie- ,- ,,\\\\ \" REFLECTING SURFACE. <br /> ,jl \II-� 1r �1 II H B �\a BLIND CORNER CABINET <br /> p Q g b 4,4, I` O SURFACE MOUNTED LIGHT PROJECT# 1827 <br /> f O <br /> OF - ' I 7A 1' 51/4" MICROWAVE&HOOD PER OWNER BAR <br /> II H� KB SPECIFICATION DRAWN BY: AT <br /> $ ;,_� A -, —� T Ob7 TUB 8 SURROUND PER <br /> \*_ � _���������h_ 6'-11 ill" STi1R OWNER SPECIFICATION. CHECKED BY: ST <br /> g G b � RANGE W/FRONT CONTROLS <br /> E � 0� 7A { b C I I O(TYPE A ACCESSIBLE UNITS ONLY) O WIRE SHELVING " <br /> NM 11'-11' 5'-Y IyD 10-1012" 5'-612" <br /> �� L-J 0• e * / 'I / RANGE HOOD ONLY.PROVIDE WALL O 2 BEDROOM PLAN& <br /> 0 9 b9 PLASTIC <br /> Lt ti t SWITCH AT 46"MAX.AFF.PROVIDE LAMINATECOUNTERTOP& ELEVATIONS <br /> U 18" 36" 18" - 11 I COUNTERTOP MICROWAVE(TYPEA BACKSPLASH PER OWNER <br /> "1` / ACCESSIBLE UNITS ONLY) SPECIFICATK)N. <br /> MAX."ADACOMPLIANT"REFRIGERATOR 10 VANITY CABINETS. OWNER <br /> 1 SPECIFICATION. <br /> id AX.sr HT.AFF TO FREEZER <br /> 6 MIN.20 GA.STAINLESS STEEL <br /> 'ill. / "+ \2 BED-ALT-B2-SINK r 2 2 BED-ALT-B2 BATH 2 BEDROOM UNIT-TYPE B-ELEV MOD 2�. KITCHEN SINK CONS O <br /> 1/4"=1-0" 1l4"=1'-0" 1/4"=1'-0'- UNIT 2.4 09/01/2021 <br />