Laserfiche WebLink
i PARKING NOTES IIIIIIIIIIIMIIMIIMI <br /> / iT C11"=4'-0"12, 4> <br /> 1. SEE SHEET A001 FOR REQUIRED♦ <br /> PARKING CALCULATIONS. JOHNSON BRAUNDINE <br /> 2. PARKING STALL SIZE 15200 52nd Ave.South <br /> a <br /> Suite 300 <br /> io <br /> Dfl E=8'43"X 16-0"MIN. Seattle,WA 98188 <br /> 'n (20 FT.MIN DRIVE AISLE) Phone 208.766.8300 <br /> 1/8" wenerennsonbaund cam <br /> •/ /p El=8,6"X 18-6' ARCHITECTURE <br /> \ } 11 ' `•J1 (24 FT.MIN.DRIVE AISLE)O INTERIOR DESIGN <br /> J1 Greg L.Alknne. <br /> 3. ACCESSIBLE STALLS: Jeffrey A.Williams. <br /> 18 b - 18, ❑ STANDARD:B'-O'MINWlOTHW/6-0" <br /> -, 4A HC ACCESS AISLE ALONG ENTIRE <br /> LENGTH OF STALL. <br /> -y-1'. <br /> . -_ 4F•4.: SEE DETAILS 19/A021 FOR SIGNAGE. <br /> BA \ \ / .\\T .- —1 6.4 4. COLUMNS ENCROACH 6"INTO <br /> / 4i .. \ REQUIRED STALL WIDTH r <br /> Z ( 5. FUTURE DUAL ELECTRICAL VEHICLE <br /> I I ®CHARGING INFRASTRUCTURE. <br /> SEE SITE PLAN A020 FOR <br /> �\ _ IP'�,- • t ADIDIT9NAL INFO,RMATI(ZN <br /> 3'-117re"/ SHEET NOTES <br /> :�4'-1 V8"MIN.d �6 \ RARCHITEGISTEREDECT <br /> _—- -—-—- - - - I <br /> 1. PODIUM CONSTRUCTION TYPE IA <br /> STAIR ill BC <br /> ALL LEVELS FULLY SPRINKLERED PER <br /> 1, 'y I ST 1 l BC 903.3.1.1(NFPA 13). FFRE1 ARTHI'R RIWALI <br /> - � STATE OF WASHINGTON <br /> L. 3. <br /> REFER TO SHEETS CS03 FOR FIRE <br /> N " ASSEMBLY8S REFER TO <br /> SUMP <br /> >in 78 LOCATIONS.TAGS B REFER TO <br /> ;Y=====" ;� SHEET SERIES A040 FOR ASSEMBLY <br /> ___--- old DETAILS. <br /> 0 0 0 O ^ ® 4:4 •dR 4. I. -• •I INDICATES <br /> CONCRETE WALL OR COLUMN PER <br /> STRUCTURAL <br /> p <br /> K a <br /> 4 5. EXIT STAIR ENCLOSURES IN TYPE 1A <br /> ____===-fir CONSTRUCTION SHALL BE 3-HOUR <br /> a ,I• RATED <br /> - r 7 i I I - '11 qF ALL VERTICAL SHAFTS SHALL BE 2- <br /> i I - ;, 8' HOUR RATED PER IBC 713.4. <br /> —Q it" 7 O SHEET A100-SEE SCHEDULE <br /> L r 1_,___ C;l B.3 X / 0 <br /> 8. REFER TO SHEET SERIES A100 FOR E <br /> I I _, / 2 BLDG B-GARAGE SOUTH-ENLARGED STAIR PLAN UNIT PLAN DOOR WINDOW <br /> M $ <br /> • <br /> - -- - - SCHEDULE. •$c <br /> a I I I � S <br /> 2 9. REFER TO SHEET SERIES A100 <br /> I� 6 �, FOR ENLARGED UNIT PLANS <br /> • <br /> it 81 <br /> ___I ,�� � --_- KNOX BOX LOCAT O B - I I 10. REFER TO ACCESSIBILITY NOTES <br /> \ I m A321 FINAL LOCATION TO BE /~ -• ON SHEET CS00 1 <br /> a A322 2 -a n VERIFIED IN FIEL `\ _ <br /> • / I I \� -- II_--� \d // 11. PROVIDE MECHANICALLY $ g <br /> B.0 b I - I N I FASTENED INSULATION AT ALL M1 <br /> II I CEILINGS BETWEEN CONDITIONED g <br /> �yy� bj AND UNCONDITIONED SPACE, ce <br /> min r ___. . 1�f11) e+ I 1 I . • 1 I / REFER TO SHEET A040 FOR <br /> I \ I© \ REQUIRED R-VALUES. <br /> m <br /> I © m 28'� • <br /> 10" / 18 it ____. 4A -LLB <br /> ��9 CORRIDOR VENTILATION CONCEPT <br /> ® I ` �`\ , - -. -. .4 .. .. l { �/ _ MECHANICAL CAL PLANS. <br /> ESIGN/BUILD <br /> KNOX BOX LOCATION, \\raiew_\\\\\\\\ VAN 18 I r— L <br /> 410 FINAL LOCATION TO BE - I _ _-_ •__—-— _ _ I •I-_y I-_ _- 0 -_ / _-_ —I 13. BF.E.C. 'SLB ABC'RECESSED/FIRE a <br /> VERIFIED IN FIELD_ L u� _ __ _/ <br /> �_ _--I--__ _1—_i •_ • _—_—_—_ —_—___ _ -—_ EXTINGUISHER CC.BINET <br /> o I io y e io ( iB F I <br /> NR#Tgli <br /> mAINT NCE 114 izr <br /> _ FE. SURFACE MOUNTED'SLB ABC'® ! 1 __ • / FIRE EXTINGUISHER CABINET 4 <br /> r (1)75 FT.MAX.SEPARATION <br /> 4e D • •-\ `,\,.• � b _ DN— • ____ // LOCATE PER IBC TABLE 906.3 <br /> l� m� I \\\1V`��` - 29 m ,1D,4D ��1 I SEE DETAIL 3rA051 FOR <br /> ( _—___ _ _ —_ _ O AS MOUNTING/INSTALLATION <br /> ♦ `___ kt1BeY \ 32 1 C I — / HEIGHT i' <br /> I I i it i I i I L 1 002 LEV W- I I \ - - - \ - .\ ^�.\\ l / 18 Rd 75. EXRI SIGN PER IBC 1013 m a <br /> =— pIE}c�-2 H I (T. I I m R "/ --H k i6. REFER TO DESIGN/BUILD 3 m <br /> o I L I T F� �' I >q m 40 1D 2q L J 1B` I I •I m ` I ELECTRICAL PLANS. L m <br /> I II FV <br /> e• ' I I- -. .�... - / 17. A051 FOR l REFER TO SHEET 8 <br /> 1 HI-f - -- -S3/a_—a-53M- 7• � --- ------- ----- ----I-^ --- --- -- -- RECCENTER _ -___ __ __ s_ <br /> ♦ PENETRATION REQUIREMENTS IN o g o <br /> E1 _ • FIRE RATED CONSTRUCTION. _ °' w <br /> �� ;�. `ICI I F 1B i-— LOCATION OF ELEVATOR o REFERENCE A700 SERIES FOR PLANS — / �/ 18. REFERENCE BUILDING ENVELOPE 0 W cai 2 y 'A <br /> 1 a 9 DRAWINGS FOR ALL WATERPROOFING- 5'.h <br /> SUMP PUMP,SEE r; U m =rn <br /> )o, 6, 0• I PLUMBING DRAWINGS 1 m l / 4„..... <br /> 19. AT DOORS INTO ELECTRICAL CONTROL L o a h <br /> IT rn� I ,r, 1 - \ / PANEL ROOMS,SIGNAGE SHALL BE 3 Q w U z g b <br /> I _ \ - - I PROVIDED ON THE DOOR STATING = gg g'� <br /> WI �GIC I / �` 'ELECTRICAL ROOM' LL co o e-m W s <br /> b <br /> U 009 I / 21-0 / -11" 3 io / // .,^ / 20. AT DOORS INTO FIRE PROTECTION <br /> I © 1 L I1D�1D1I `�/ / _ h0 0� CONTAINING <br /> SPRINKLER RISERSEQUIPMENT ,ACP,OR OTHER <br /> �y ® CIF '-'. o ::F.E. I - _ -q F.E. - - .� "/�•-1 -_.�.� -.::��' L / aA' B.7 h,,1� / ('/-N SUPPRESION CONTROL ELEMENTS, <br /> E I I m14_ © • <br /> X ♦ I l L— ' '•\ APPROVED SIGNAGE SHALL BE <br /> rmD 1 4C i 4 / I 19'-8" SC /4'_B"FL/J'723 E pi• 1 �, / "'I' /•��/`�/ \ _-- FC 509,1DANO READILY VISIBLE PER <br /> NN, <br /> li I -'F'_ I I / 2a•-o" / I___lll.���.---- / / h / KEY PLAN <br /> N <br /> m t I I �O .11 <br /> / b� // / <br /> Et'I 72 i Dt 18 CI I I1DI4DI--.. //✓ // •� ��e • <br /> I I I <br /> / <br /> 10'�5'___Mil_ _ I 26-A' t�• - _� / / PROJECT#: 1827 <br /> I / d\ <br /> _ 1• I 1. -- I1� 4A 1B T - - - - _\\`a` / B 8 DRAWN BY: AT <br /> • 5 GARAGE SCREEN �Z-Er, GARAGE SCREEN I -C • / CHECKED BY: ST <br /> B 1•- I 1S-2' X 16-1' t I J I2S-0" w I —T6'-1" 27•-6•— / <br /> } <br /> j `-✓---/Q-1�-� -✓-L�.�.-F./-✓ti-. �-.i-.�-✓-�r�^ .�-'� •I85._2• / / / <br /> / \\ / / BLDG B-GARAGE <br /> ti I / I / / ti° SOUTH <br /> • <br /> B.a I B.b B.c / ( 2 B.f CD �- R / R4 B.h <br /> wAI © 010 <br /> EEC I 1 / // / BUILDING B <br /> W IZIP0' 29 ' CONSTRUCTION SET <br /> _ / 1�•1 BLDG B-GARAGE SOUTH 09/01/2021 <br /> . --- _- - -- -- -- / 1/e 1 0 ---- -- - <br />