Laserfiche WebLink
SPECIFICATIONS: MXZ-2C20NA2 <br /> Non-Ducted Mixed Ducted <br /> Type R410A R410A R410A <br /> Refrigerant <br /> Charge Lbs.Oz. 5,15 5,15 5,15 <br /> Maximum Number of Connected IDU 2 2 2 <br /> Minimum Number of Connected IDU 2 2 2 <br /> Indoor Unit <br /> Connection <br /> Maximum Connected Capacity Btu/h 24,000 24,000 24,000 <br /> Minimum Connected Capacity Btu/h 12,000 12,000 12,000 <br /> Gas Pipe Size O.D.(Flared) In.[mm] 3/8[9.52] 3/8[9.52] 3/8[9.52] <br /> Liqued Pipe Sixe O.D.(Flared) In.[mm] 1/4[6.35] 1/4[6.35] 1/4[6.35] <br /> Total Piping Length Ft.[m] 164[50] 164[50] 164[50] <br /> Piping Maximim Height Differeence,ODU above IDU Ft.[m] 33[10] 33[10] 33[10] <br /> Maximim Height Differeence,ODU below IDU Ft.[m] 49[15] 49[15] 49[15] <br /> Farthest Piping Length from ODU to IDU Ft.[m] 82[25] 82[25] 82[25] <br /> Maximum Number of Bends 50 50 50 <br /> *1 Cooling(Indoor//Outdoor) °F 80°F DB,67°F WB//95°F DB,75°F WB <br /> AHRI Rated <br /> Conditions <br /> (Rated data is *2 Heating at 47°F(Indoor//Outdoor) °F 70°F DB,60°F WB//47°F DB,43°F WB <br /> determined at a <br /> fixed compressor <br /> speed <br /> *3 Heating at 17°F(Indoor//Outdoor) °F 70°F DB,60°F WB//17°F DB,15°F WB <br /> Conditions *4 Heating at 5'F(Indoor//Outdoor) °F 70°F DB,60°F WB//-4°F DB,-5°F WB <br /> For actual capacity performance based on indoor unit type and number of indoor units connected,please refer to MXZ Operational Performance. <br /> Although the maximum connectable capacity can exceed rated,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or <br /> applications where it is known that all connected units will NOT be operating at the same time. <br /> NOTES: <br />