My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
928 HOYT AVE 2022 Plans 2025-07-07
>
Address Records
>
HOYT AVE
>
928
>
Plans
>
928 HOYT AVE 2022 Plans 2025-07-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2025 1:51:04 PM
Creation date
7/7/2025 1:50:47 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
928
Permit
B2208-059
Year
2022
Notes
REMODEL THE UNFINISHED BASEMENT, ADD BATHROOM & LAUNDRY RM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WINDOW SCHEDULE Smoke Detectors Requireu <br /> SYM.NO. I WIDTH HEIGHT AREA 1 WINDOW TYPE I U-VALUE I COMMENTS Z a <br /> • In each sleeping room, <br /> - _ 4 BASEMENTEW 31 2'-0' 8SF PICTURE(FIXED) 0.30OOR • In each room giving access to a * L. E <br /> 6 3'-0" 2'-0• 8SF SLIDER 0.30 • <br /> awl <br /> IXSTBAN,F<�R sleeping room, <br /> Z $$_ <br /> u Is-o 2-o BSF [PICTURE(FIXED) 10.30 <br /> Grand total 18 SF • Interconnected, ; m <br /> R. <br /> ® Battery backup, <br /> .. OFFICE ® Hardwired. <br /> DOOR SCHEDULE3 <br /> SYM.NO. WIDTH HEIGHT DOOR TYPE COMMENTS RE-LOCATE- EXISTING <br /> nNG <br /> NEW BASEMENT FLOOR -- -- ,____ —� T. HOT WATER TANK \ <br /> D12 2'-8• 6'-8" SINGLE PANEL \ '1 <br /> D15 2'-8' 6'-8• SINGLE PANEL I \ ` <br /> D19 4'-0" 8-V. BIFOLD 4 PANEL CLOSET DOOR Double bio6 closet door w.-_4 <br /> 12 <br /> D20 2'-8• 8'-8" SINGLE PANEL :36 .n3:T-+1,:. • - <br /> EXIST.BASEMENT FLOOR 4 <br /> ."1._ 12 <br /> D2 2'-4• V-8• SINGLE PANEL El <br /> D21 2'-8• 8'-8' SINGLE POCKET Pocket door 2'-7 _ = Gs T,"'-3A <br /> 1ST FLOOR _ 2' 3" - 13 R<Ge 4C.sigc rig, <br /> 09 12'-4" I6'-8• /SINGLE PANEL / Y iaocri- a. Rlant f�E��,SnafS£1fl <br /> EXISTING PIPE g} r 2 C " <br /> BEDROOM LIVING RM. 4• <br /> TEXo�REx�wr6ir POSTS of =� fr � € py141 <br /> EXISTING EXISTING e y - - W-tY' <br /> CRAWLSPACE 1 - ;oil <br /> KEYNOTE SCHELDULE ?"— / M " <br /> KEY VALUE TEXT BATH' , f 5.-11114 <br /> LINEN CL f EXIST.P ST <br /> 02 LANDINGS:THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR.LANDING OR FLOOR SHALL BE A MAX.1 5" _ <br /> LOWER THAN THE TOP OF THE THRESHOLD,7 3/4•IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING MAX ? =L.r <br /> LANDING SLOPE IS 1M:12.(R311.3.18311.32) /O._so lzr - `- f• �D20;: <br /> OB GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES,PORCHES,STAIRS,RAMPS,BALCONIES AND LANDINGS LOCATED - <br /> MORE THAN 30•ABOVE THE FLOOR OR GRADE BELOW.GUARD SHALL NOT BE LESS THAN 36•IN HEIGHT.OPEN RAILS SHALL HAVE _ - .a s.�., D15 _I. <br /> INTERMEDIATE RAILS SPACED SO THAT A4•SPHERE CANNOT PASS THROUGH.(R312) - - -. \ <br /> 08 EGRESS WINDOWS OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS.BOTTOM OF CLEAR OPENING IS NOT TO CONTRACTOR TO VERIFY 5-712• <br /> EXCEED 44•ABOVE FLOOR.OPENABLE AREA IS 5.7 S0.FT NET CLEAR MIN EXCEPT 5.0 SQ.F7.IS ALLOWED FOR AN OPENING WITHIN 44' I EXISTING SMOKE DETECTORS <br /> OF FINISHED GRADE(R3101) AT EXISTING BEDROOMS AND I <br /> 10 DRYER 4O VENT TO OUTSIDE AND PER MANUFACTURERSPECICATIONS.DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND OU I HALLWAY AND/OR REPLACE i I I `o' O 2L�NEW 3050 O <br /> CONSTRUCTED OF METAL MAX.DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.42.(M1502) - Co.so OR ADD AS NECESSARY. REPLACE EXISTING <br /> 3020 W NDOW NEW I I EGRESS <br /> 12 PILOTS,BURNERS,&SWITCHES TONEIB"MIN.ABOVE FLOOR.ALL APPLANCESTONEU.L.RATED.DUCTS IN GARAGE AND THOSE - 3020SLIDER t ", 9 BED/OFFICE I N�WUNG 5� •2\ <br /> PENETRATING THE WALLS OR CEIUNGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA SHEET STEEL AND SHALL HAVE <br /> NO OPENINGS IN THE GARAGE.WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH __ m REC ROOM I �� <br /> M13072.PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. _-_-- S <br /> DINING RM. NEW 2z4 STUD WALL -- <br /> 13 FUEL FIRED APPLIANCES:WHERE THE VOLUME OF THE SPACE IN WHICH THE APPLIANCE IS LOCATED IS GREATER THAN 50 CU.FT.PER - zv <br /> 1000 BTUM THEN NO VENTILATION IS REQUIRED.IF LESS,PROVIDE VENDLATION IN ACCORDANCE WITH G2407.5. EXISTING OFFSET2"FROM FOUNDATION �r M M �S <br /> BATH WALL w/R-21 BATT INSULAT ON. I <br /> ' 24 FIBERGLASS TUB w/TILE SURROUND AND CURTAIN OR TEMP.GLASS DOOR PER BUILDER SPECIFCATIONS. REMOVE POSTS 3'-1• <br /> © EXISTING _ i (3'CLEAR) <br /> ©� — aH <br /> 2 7�{J <br /> © ® •0 UP pgas tA` <br /> 44 - � OI <br /> � NEW FRAMED WALL I )0�, <br /> - �1! s I ',0 Nl bf) <br /> c - z 11 1 °° v "' o <br /> AMU DEMO PORTION OF REPLACE EXISTING rc J <br /> _ EXSTING WALL 3020 WINDOW w/NEW I' Y W t,/ <br /> �.�__ �{ BEAM IN WALL FOR I 1 I f REPLACE EXISTING m <br /> FOR NEW STAIRWAY , 3020 SLIDER 0 Z <br /> NOOK UNDER STAIRS Idi. EXISTING ( 3 3020 WINDOW w/NEW <br /> I 111111 I POSTS 30205DDER TO FIT --`,r O W 3 <br /> a� (OWNER TO VERIFYCI <br /> IiIN 1 , ROUGH OPENING) K <br /> I BEDROOM I I. K_1 I KITCHEN �10-912• I- �s - W w <br /> EXISTING I��1�_ EXISTING - ''.,I LAUNDRY F w <br /> © Z LU <br /> \ �' it pN r _ CLOSET OR a. -_ <br /> A • STORAGE �' = W U = <br /> HANDRAIL,GUARD AND UNDER D21 G C `l > <br /> BALUSTERS TO CONFORM TO RESIDENTIAL STAIRS TO BE - STAIRS - " _ E CW J a <br /> I.R.C.OPENPAGS SPACED MIN.36"(CLR)WIDE. sl . i J <br /> SUCH THAT A4•SPHERE -- $ 9 _ i'. \, _ 1 �� "-V) w w i <br /> CANNOT PASS THROUGH. i1- - ae <br /> --__._ -1 ® _ - - _._ _ t <br /> 1 1/4"DA.MIN;2•DA MAX. Q ;• a NOTE VERIFY NO EXISTING 1 ELECT.PANEL m O -4 a <br /> 02•. ATTIC OR ROOF SUPPORTS <br /> 0 HANDRAIL w/RETURNS TO nr °' OVER STAIR OPENING. <br /> 0 WALL. <br /> E <br /> • <br /> TRIANGLE OF STEPS TO RAIL - <br /> i OPENING SPACED SUCH THAT A <br /> i 6"SPHERE CANNOT PASS THRU. 1 - -_ <br /> 10"MIN. 'IIlis DBL IN - <br /> -.� Y— (UN.O.NA PLAN) I <br /> _ 1ST FLOOR r I I � ,/ D' 2 aa' 8' 16 <br /> II �Ti va"=r-o" <br /> II I IIo SMPSON <br /> LLUS2IU JOIST <br /> SMPSON A35 <br /> mAII III BRINGERS EACH SIDE OF NEW BASEMENT FLOOR <br /> RINGERRS WALL LEGEND 2 = <br /> 1/7 GINS <br /> FIRE BLOCK BETWEEN STUD NEW WALLS <br /> MINI BAYS AT WALLS IN CONTACT 2a12 STRINGERS i PROJECT NO. 211005 <br /> 3/4" <br /> 14" MAX WITH STRINGERS. PER PLAN -I EXISTING WALLS TO REMAIN DESIGNED BY rt. <br /> 1/NOSING DRAWN BY IL 8 12"MIN.PLYWOOD -RISERS 4 WALLS AND STRUCTURES TO BE REMOVED RM <br /> CHECKED BY R <br /> SHEET NO. <br /> ©TYPICAL STAIR DETAIL <br /> 3/4"=1'-0" <br /> A3 <br /> PRINT DATE 7/14/2022 5:29:16 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.