�._._,_,_• _PROPERTY LINE PILE SPACING&LOAD REQUIREMENTS TABLE - �p• ,' <br /> 201'-0' •- • MAX O.C.SPACING,ft MIN VERTICAL CAPACITY,kips PROOF TESTING LOAD,kips <br /> PILE# PILE TYPE 200%MIN VERTICAL CAPACITY LOCATION .�' " <br /> •_•_•_`�•�•�i BTWN PILES END OFFSET ALLOWABLE LOADING (MIN ULTIMATE CAPACITY) '' ' .' <br /> I 1-2 8.0 k/PILE 16.0 k/PILE EXTERIOR <br /> I 3-7 12.0 k/PILE 24.0k/PILE EXTERIOR <br /> I 1 8 9 HELICAL 6'-0" PER PLAN 17.0 k/PILE 34.0 k/PILE EXTERIOR <br /> PARCEL NO. I 10-12 16.0 k/PILE 32.0 k/PILE DECK <br /> 00644500001300II NOTES: <br /> I LEGAL DESCRIPTION <br /> i GRANADA SEAVIEW ESTATES DIV. 4A I a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE <br /> NO.1 BLK 000 D-00-LOT 13 TGW S MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING <br /> 20FT OF VAC PTN HILLSIDE LANELY CAPACITY LOADING,INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT <br /> ADJ TO SD LOT PER CITY EVERETT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM <br /> INSTALLATION TORQUE RATING OF 8.300FT'LBS FORA 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL <br /> I ORD NO.255-73 RECORDED 718/420S i THICKNESS PER ESR-3750. <br /> AUD FILE NO.2310434 b. FOR HELICAL PILES,PER IDEAL GROUP DWG NO.:278TFG,THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 7/8" 11.1 } <br /> •,'6‘ <br /> TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 30 KIPS. Z <br /> OWNER NAME&ADDRESS bc1 I <br /> MIYASAKI GARY ANDREW& o% C. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC., IN ACCORDANCE WITH ESR-3750. H D w <br /> (E)DECK d. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART Z 0 <br /> STEPHANIE MARIE DELEONI 5008 23RD AVE W I OF THE ASSEMBLY. F- W . <br /> EVERETT,WA 98203 I e. MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. - z <br /> I j= FOUNDATION NOTES O z z <br /> oicc 1. VERIFY ALL DIMENSIONS ON SITE. <br /> a <br /> o.w 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER R&R LEVEL SURVEY. <br /> a <br /> O 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: <br /> •% i - HELICAL PILE..........1/SD-1.1 <br /> 4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED APRIL 13TH,2022,FOR ADDITIONAL INFORMATION,SPECIFICATIONS, <br /> • / RESIDENCE I AND REQUIREMENTS. ,/� <br /> �'�, 5008 23RD AVE W <br /> -IH 1• 5. LEVEL SURVEY PER R&R REPAIR PLAN DATED DECEMBER 21ST,2021.REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR '� <br /> m•� EVERETT.WA 98203 <br /> Io y i MODIFICATIONS AND ADDITIONAL REQUIREMENTS FOR REPAIR PLAN. <br /> Y r„/^ 6. MINIMUM PILE DIAMETER SHALL BE 2-7/8'. <br /> m I • /^ C3 I 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH±0,6"TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS , <br /> 1 10. <br /> /1 ENCOUNTERED DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION AS INDICATED <br /> i +� `Y NZ I H F ON LEVEL SURVEY. <br /> ,V S 4'-6" I 9. FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8'THICK MINIMUM WITH 2'-8"HEIGHT <br /> TG TO T/CONC)MINIMUM. <br /> �% �\•�c` 41-OII Y�qi9 Op-\��1H i 10.PARCEL DIMENSIONS(MEASURED FROM FPROVIDED BY CITY OF SEATTLE.NOT TO SCALE.PROPERTY LINE AND RESIDENCE LOCATING DIMENSIONS(WITH <br /> • mod, /.. PO'G I ASTERISK,•)APPROXIMATED PER KING COUNTY iMAP AND SEATTLE DEPARTMENT OF CONSTRUCTION AND INSPECTIONS GIS MAPPING <br /> •• i TOOLS.NOT TO BE USED FOR LEGAL PURPOSES. <br /> I 11.SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FOR CLARITY. <br /> 1 12.REFER TO GENERAL NOTES FOR PILE FIELD TESTING REQUIREMENTS. <br /> AREA OF WORK \ /' <br /> 1 126. ‘ \ <br /> /. <br /> /• HELICAL PILE REFUSAL CRITERIA. <br /> \j .....• TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL <br /> I /. <br /> Y+\O, /• CAPACITY WITH A SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS <br /> I O /•/• TO EXPERIENCE UPLIFT FLEXURE. <br /> 1 s\\ `L3 /• <br /> !•/• 5008 23RD AVE W <br /> / /•/• SITE PLAN LEGEND EVERETT <br /> `9c` /• WA 98203 <br /> p'/•/ I I EXISTING RESIDENCE STRUCTURE '•, Si <br /> t DWI S220112-3XR <br /> /...... EXISTING ADJACENT STRUCTURE e- -mom. <br /> /• <br /> j /•/• , AREA OF PROPOSED WORK PIP•FC®6 C OCMAx JT <br /> /- <br /> /• LOCATE PILE - <br /> d`/� PROPERTY LINE WITHIN 70" `� .. - MRT <br /> �35�.J\...• FROM CORNER <br /> %�Q�(i APPROXIMATE DIMENSION LOCATE PILE se m �. _ 04/13/2022 <br /> •/•/• Q WITHINNER ' `., . <br /> • „ • In.tmtm rstr <br /> .0.. <br /> FROM CORNER - ,r,III, <br /> •/ 5-0' <br /> c. ,OC MAIL•-, .. PROVIDE CFCR AROUND FULL CIRCUMFERENCE OF <br /> /•/ COLUMN.MIN 1-6-BEYOND EXTENTS OF THE OBSERVED <br /> i /• Project Description Lot Coverage by Building sI PILES® CRACKING ABOVE AND BELOW <br /> CFCR SUPPLIER TO PROVIDED CONTAINMENT EQUIVALENT <br /> /• Foundation Stabilization/Jacking Lot Size=0.75 acres=32,670 SF 6`0'O0 ,,- > i I TO A to SPIRAL WITH A 3'PITCH. <br /> /• THE COLUMNS SHALL BE MONITORED AND A STRUCTURAL <br /> /• 5008 23RD AVE W Existing House=1,900 SF* I ENGINEER CONTACTED FOR FURTHER ASSFSSMENT IF <br /> E FUTURE. <br /> I /•/• EVERETT,WA 98203 Bldg SF/Lot SF=5.8%* NOTE THAT LL 120 HAS NOT HECOLUMN <br /> i ........... <br /> //• r.�A- Stp I tM OR LATERAL SYSTEM OF THE PRIMARY <br /> / LOCATE PILE STRUCTURE AND IS RECOMMENDING THE CFCR ON THIS <br /> WITHIN 1'-0' WI PILES G-0'OC MAX COLUMN AS A PRECAUTIONARY MEASURE ONLY <br /> ...... * <br /> /• S 20FT OF VAC PTN HILLSIDE LANELY ADJ TO SD LOT PER CITY Note:Imprevious area to remain unchanged <br /> /• EVERETT ORD NO.255-73 RECORDED 718/420 AUD FILE NO.2310434 <br /> I /• <br /> /• *approximate <br /> /•/• Parcel Tax I.D.No. <br /> I / • 00644500001300 R&R LEVEL SURVEY <br /> '/•// See Structural Calculation Package for Additional Requirements <br /> I <br /> V. <br /> Height Calculations <br /> Survey not performed. Z N <br /> a Ch <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. SITE PLAN 1- <br />