ENERAL STRUCTURAL NOTES ABBREVIATIONS
<br /> DESIGN CRITERIA HELICAL PILES CONCENTRIC DRIVEN PILES AB ANCHOR BOLT FTG FOOTING iJ
<br /> CODE:2018IBC/IRC&AMENDMENTS AS ADOPTED BY THE REVIEWING AGENCY/COUNTY, 1. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2015 INTERNATIONAL 1. 'CONCENTRIC'OR DRIVEN PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE ABV ABOVE GA GAUGE �Jr���F
<br /> ROOF 25 PSF SNOW(GROUND) BUILDING CODE(IBC). 2015 INTERNATIONAL BUILDING CODE(IBC). AFF ABOVE FINISH FLOOR GALV GALVANIZED
<br /> FLOORS 2. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED BY IDEAL MANUFACTURING,INC.,AND SHALL BE 2. IT IS RECOGNIZED THAT THE SEATTLE BUILDING CODE(SBC)REQUIRES 8 INCH MINIMUM DIAMETER PIPE ALT ALTERNATE GLB GLULAM BEAM
<br /> RESIDENTIAL 40 PSF IN ACCORDANCE WITH ESR-3750. FOR PIPE PILE INSTALLATION.THE APPROPRIATE ANALYSIS/EVALUATION AND TESTING REQUIREMENTS IN ALUM ALUMINUM GR GRADE
<br /> BALCONY/DECK 60 PSF 3. ALL MATERIAL PROPERTIES OF HELICAL PILE COMPONENTS SHALL BE IN ACCORDANCE WITH ESR-3750. ACCORDANCE WITH SEATTLE DEPARTMENT OF CONSTRUCTION B INSPECTIONS(SDCI)DIRECTOR'S RULE APPROX APPROXIMATE GYP GYPSUM WALL BOARD
<br /> 4. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES ACCEPTANCE 10-2009 ARE PROVIDED TO ALLOW FOR USE OF PILES LESS THAN B INCHES IN DIAMETER AS REQUIRED BY AK ALASKAN YELLOW CEDAR HDG HOT-DIPPED GALVANIZED
<br /> GENERAL CONDITIONS CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING POLYMER(EAA) SECTION 104.5 OF THE SBC. BB BOX BEAM HDR HEADER
<br /> 1. THE CONTRACTOR SHALL EXAMINE THE STRUCTURAL DRAWINGS AND SHALL NOTIFY THE STRUCTURAL COATINGS(AC228). 3. DRIVEN PILES SHALL BE DESIGNED AND MANUFACTURED BY STABIL-LOC SYSTEMS,LLC,AND SHALL BE IN BF BOTTOM FLUSH HF HEM FIR
<br /> ENGINEER OF ANY DISCREPANCIES HE MAY FIND BEFORE PROCEEDING WITH THE WORK. 5. ALL HELICAL FOUNDATION COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE ACCORDANCE WITH ESR-4121. BLDG BUILDING HGT HEIGHT
<br /> 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE REINFORCING STEEL,BUILDING STRUCTURAL STEEL,OR ANY OTHER METAL BUILDING COMPONENTS PER 4. ALL MATERIAL PROPERTIES OF DRIVEN PILE COMPONENTS SHALL COMPLY WITH ESR-4121. BLKG BLOCKING HT HEIGHT
<br /> STARTING WORK.THE ARCHITECT/ENGINEER SHALL IMMEDIATELY BE NOTIFIED IN WRITING OF ANY AC358 SECTION 3.9. 5. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES ACCEPTANCE BM BEAM IN INCH
<br /> DISCREPANCIES. 6. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS. CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING POLYMER(EAA) BOT BOTTOM JT JOINT
<br /> 3. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS SHALL 7. ONLY MANUFACTURER-APPROVED CONNECTORS,ADAPTORS,AND ACCESSORIES MAY BE USED. COATINGS(AC228). BP BOTTOM PLATE MAX MAXIMUM
<br /> BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER BEFORE 8. HELICAL PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE OF 6. ALL PILE COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE REINFORCING STEEL, BRG BEARING MIN MINIMUM W
<br /> PROCEEDING WITH ANY WORK SO INVOLVED. INCLINATION OF N-1 DEGREE FROM VERTICAL PER SECTION 4.2.1 OF ESR-3750. BUILDING STRUCTURAL STEEL,OR ANY OTHER METAL BUILDING COMPONENTS PER AC358 SECTION 3.9. BTWN BETWEEN MISC MISCELLANEOUS 0 0 z
<br /> BSMT BASEMENT 0
<br /> 4. IN CASE OF CONFLICT, NOTES AND DETAILS OF THESE STRUCTURAL DRAWINGS SHALL TAKE 9. MONITOR AND RECORD DEPTH OF PILE PENETRATION.PROVIDE TORQUE MONITORING DEVICE AS PART OF 7. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS. NB NON-BEARING
<br /> B/W BOTTOM OF WALL
<br /> PRECEDENCE OVER THE"GENERAL NOTES"AND/OR'STANDARD DETAILS". THE INSTALLING UNIT.MONITOR AND RECORD TORQUE APPLIED DURING THE INSTALLATION OF EACH PILE 8. ONLY MANUFACTURER-APPROVED CONNECTORS,ADAPTORS,AND ACCESSORES MAY BE USED. NO NUMBER Z o
<br /> 5. IF A SPECIFIC DETAIL IS NOT SHOWN FOR ANY PART OF THE WORK,THE CONSTRUCTION SHALL BE THE AT SPECIFIC DEPTHS. 9, DRIVEN PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE OF CANT CANTILEVEROC ON CENTER I- al
<br /> CJ CONTROL JOINT z
<br /> SAME AS FOR SIMILAR WORK. IS. HELICAL PILES SHALL BE INSTALLED TO THE MINIMUM TORQUE VALUE REQUIRED TO PROVIDE THE INCLINATION OF 1 DEGREE FROM VERTICAL PER SECTION 5.7 OF ESR-4121. CLG. CEILING PSF POUNDS PER SQUARE F00T E
<br /> 6. WORKING DIMENSIONS SHALL NOT BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THESE MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF SAFETY NO LESS 10. DRIVEN PILES SHALL BE INSTALLED TO THE MINIMUM FORCE REQUIRED TO PROVIDE THE MINIMUM PSI FOUNDS PER SQUARE INCH w
<br /> CI.) CEILING JOIST Z W z
<br /> DRAWINGS. THAN TWO(2).THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO(2). CIA CLEAR PT PRESSURE TREATED z
<br /> 7. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE STRUCTURAL ENGINEER OF ANY CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE PILE ASSEMBLY. THE MAXIMUM INSTALLATION FORCE SHALL NOT EXCEED THE ALLOWABLE CAPACITY OF ANY INDIVIDUAL CMU CONCRETE MASONRY UNIT RAF RAFTER O a
<br /> w
<br /> CONDITION WHICH IN HIS OPINION MIGHT ENDANGER THE STABILITY OF THE STRUCTURE OR CAUSE 11. ALL BRACKETS AND HELICAL PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY TO ACHIEVE COMPONENT OF THE ASSEMBLY. COL COLUMN REF REFERENCE J
<br /> DISTRESS TO THE STRUCTURE. THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO(2). 11. ALL BRACKETS AND PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY TO ACHIEVE THE CONC CONCRETE REINF REINFORCEMENT
<br /> 8. THE CONTRACTOR SHALL SUPERVISE AND DIRECT HIS WORK AND HE SHALL BE SOLELY RESPONSIBLE 12. REPAIR BRACKETS MUST BE CONCENTRICALLY LOADED AND THE BRACKET PLATE MUST BE FULLY MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO(2). CONN CONNECTION REQD REQUIRED
<br /> FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. PROVIDE ENGAGED WITH BOTTOM OF CONCRETE FOUNDATION. 12. THE PILE QUANTITY,LAYOUT,AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED WITHOUT CONST CONSTRUCTION SF SQUARE FOOT
<br /> ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. 13. ALL HELICAL PILE ASSEMBLY COMPONENTS MUST HAVE ADEQUATE STRENGTH TO DEVELOP THE TORQUE WRITTEN APPROVAL FROM THE ENGINEER-OF-RECORD PRIOR TO INSTALLATION. CONT CONTINUOUS SIM SIMILAR
<br /> 9. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE LATEST EDITION OF THE REQUIRED FOR INSTALLATION AND ALL INDUCED STRESSES. 13. SPECIAL INSPECTION IN ACCORDANCE WITH IBC SECTION 1705.7 IS REQUIRED FOR INSTALLATION OF THE CFR CENTER SPF SPRUCE PINE FIR
<br /> INTERNATIONAL BUILDING CODE,AND ALL OTHER REGULATING AGENCIES EXERCISING AUTHORITY OVER 14. THE PILE QUANTITY,LAYOUT,AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED WITHOUT STABIL-LOC FOUNDATION PIERING SYSTEM.A GEOTECHNICAL SPECIAL INSPECTOR MUST VERIFY AND DET DETAIL STD STANDARD ;:_-,�
<br /> ANY PORTION OF THE WORK. WRITTEN APPROVAL FROM THE ENGINEER-OF-RECORD PRIOR TO INSTALLATION. RECORD THE FOLLOWING: DF DOUGLAS FIR(SOUTH) SYP SOUTHERN YELLOW PINE
<br /> 10. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. 15. CONTINUOUS SPECIAL INSPECTION IN ACCORDANCE WITH 2O15 AND 2012 IBC SECTION 1705.9 MUST BE A. VERIFICATION OF MANUFACTURER PRODUCT MODEL NUMBERS DEL DOUGLAS FIR LARCH T/ TOP OF
<br /> WHERE THE NOTES,DRAWINGS,AND/OR SPECIFICATIONS DIFFER,THE MORE STRINGENT REQUIREMENT PROVIDED FOR THE INSTALLATION OF THE HELICAL PILES AND FOUNDATION BRACKETS.ITEMS TO BE B. TYPES,CONFIGURATIONS,AND IDENTIFICATIONS OF HYDRAULICALLY DRIVEN STEEL PIER DIM DIMENSION T/C TOP OF CONCRETE /'
<br /> SHALL APPLY. RECORDED AND CONFIRMED BY THE SPECIAL INSPECTOR MUST INCLUDE THE FOLLOWING: SEGMENT AND ADJUSTABLE HEAD ASSEMBLY AS SPECIFIED IN ESR-4121 AND THE CONSTRUCTION DJ DOUBLE JOIST T/P TOP OF PLATE
<br /> 11. REFER TO THE ARCHITECTURAL DRAWINGS FOR INFORMATION NOT COVERED BY THESE GENERAL NOTES A. PRODUCT MANUFACTURER DOCUMENTS. DIA DIAMETER T/S TOP OF STEEL
<br /> OR THE STRUCTURAL DRAWINGS. B. MANUFACTURER'S CERTIFICATION OF THE INSTALLERS C. INSTALLATION PROCEDURES,ANTICIPATED AND ACTUAL PILING DEPTH DN DOWN T/W TOP OF WALL
<br /> 12. NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. C. PRODUCT TYPE AND CONFIGURATIONS FOR HELICAL PILE LEAD SHAFT SECTIONS,EXTENSIONS, D. TIP ELEVATIONS,THE INSTALLATION PRESSURE AND FINAL DEPTH OF THE DRIVEN FOUNDATION DS DOWN SPOUT TF TOP FLUSH
<br /> 13. DISCREPANCIES FOUND BETWEEN STRUCTURAL DRAWINGS AND OTHER DOCUMENTS ARE TO BE NOTED BRACKETS.BOLTS,THREADED RODS,NUTS.WASHERS,AND TORQUES AS SPECIFIED IN THIS SYSTEM EACH TJ TRIPLE JOIST
<br /> IN WRITING TO THE ENGINEER PRIOR TO CONSTRUCTION. REPORT AND THE CONSTRUCTION DOCUMENTS E. INCLINATION AND POSITION/LOCATION OF HYDRAULICALLY DRIVEN PIER SEGMENTS EF EACH FACE T/BM TOP OF BEAM _
<br /> D. INSTALLATION PROCEDURES FOR THE HELICAL PILE SHAFT,INSTALLATION EQUIPMENT USED,AND F. COMPLIANCE OF THE INSTALLATION WITH THE APPROVED CONSTRUCTION DOCUMENTS AND THIS EJ EXPANSION JOINT
<br /> 14. ALL CONSTRUCTION SHALL BE DONE WITH MATERIALS,METHODS,AND WORKMANSHIP ACCEPTED AS ELEV ELEVATION T/SLABTOP OF SLAB
<br /> GOOD PRACTICE BY THE CONSTRUCTION INDUSTRY IN CONFORMANCE TO THE PROVISIONS OF THE THE IDEAL FOUNDATION SYSTEMS INSTALLATION INSTRUCTIONS EVALUATION REPORT. TP TOP PLATE
<br /> E. ANTICIPATED AND ACTUAL PILING DEPTH 14. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION,MISALIGNMENT.OR FAILURE TO MEET OTHER EN EDGE NAILING(PANEL)
<br /> "INTERNATIONAL BUILDING CODE'(IBC),AND STANDARDS REFERENCED THEREIN. EQ EQUAL TYP TYPICAL
<br /> F. REQUIRED TARGET INSTALLATION TORQUE OF PILES AND MINIMUM DEPTH OF INSTALLATION SPECIFIED DESIGN/INSTALLATION CRITERIA ARE NOT ACCEPTABLE.ABANDON REJECTED PILES AND
<br /> 15. STRUCTURAL STABILITY OF ALL NEW AND EXISTING STRUCTURES DURING CONSTRUCTION SHALL BE ES EACH SIDE UNO UNLESS NOTED OTHERWISE
<br /> THE RESPONSIBILITY OF THE CONTRACTOR.THIS INCLUDES EXCAVATIONS,COLUMNS,EQUIPMENT G. INCLINATION AND POSITION OF PILES,TOP OF PILE EXTENSION IN FULL CONTACT WITH BRACKET, INSTALL ADDITIONAL PILES AS REQUIRED. EW EACH WAY UPA UNDER POST ABOVE
<br /> TIGHTNESS OF ALL BOLTS AND EVIDENCE THAT THE PILE FOUNDATION SYSTEMS ARE INSTALLED
<br /> LOADS,MATERIAL LOADS,AND OTHERS.OBSERVATIONS BY THE ENGINEER-OF-RECORD DO NOT FB FLUSH BEAM UWA UNDER WALL ABOVE
<br /> INCLUDE INSPECTIONS OF TEMPORARY LOADING AND STABILITY DURING CONSTRUCTION. BY AN APPROVED IDEAL FOUNDATION SYSTEMS INSTALLER. DRIVEN PILE PROOF TESTING FIN FINISH VERT VERTICAL
<br /> 16. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION,MISALIGNMENT,OR FAILURE TO MEET OTHER THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE(3) FL FLOOR VIE VERIFY IN FIELD
<br /> SPECIFIED DESIGN/INSTALLATION CRITERIA ARE NOT ACCEPTABLE.ABANDON REJECTED PILES AND PERCENT OF PILES UP TO FIVE(5)PILES MAXIMUM(ONE(1)MINIMUM)IN ACCORDANCE WITH THE PROCEDURE FLSHG FLASHING W/ WITH 1817 HOYT AVE ,
<br /> INSTALL ADDITIONAL PILES AS REQUIRED. OUTLINED IN ASTM D1143 AND/OR THE 2015 SEATTLE BUILDING CODE(SAC).THE MAXIMUM TEST LOAD SHALL BE END FOUNDATION WC WESTERN CEDAR
<br /> TWO-HUNDRED(200)PERCENT OF THE SPECIFIED DESIGN LOAD. EVERETT,WA
<br /> FP FIREPLACE WP WATERPROOF
<br /> CONCRETE ANCHORS HELICAL PILE PROOF TESTING 98201
<br /> FT FOOT WWF WELDED WIRE FABRIC
<br /> 1. ALL SPECIFIED CONCRETE ANCHORS SHALL BE SIMPSON STRONG TIE,HILTI,OR EQUIVALENT.SPECIAL THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE(3)
<br /> INSPECTIONS REQUIRED. PERCENT OF PILES UP TO FIVE(5)PILES MAXIMUM(ONE(1)MINIMUM)IN ACCORDANCE WITH THE PROCEDURE
<br /> OUTLINED IN ASTM DI143 AND/OR THE 2015 SEATTLE BUILDING CODE(SBC).THE MAXIMUM TEST LOAD SHALL BE S210803-1 XR
<br /> STRUCTURAL AND MISC.STEEL TWO-HUNDRED(200)PERCENT OF THE SPECIFIED DESIGN LOAD.
<br /> 1. REFERENCE STANDARDS:DESIGN,FABRICATION AND ERECTION ARE TO BE IN ACCORDANCE WITH THE NJ
<br /> LATEST EDITION OF THE AISC"CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES".
<br /> 2. MATERIALS:
<br /> M RT
<br /> BOLTS-ASTM A307,UNLESS OTHERWISE NOTED
<br /> WF BEAMS-ASTM A572-50(Fy=50,000 PSI) 9/26/21
<br /> HSS ROUND COLUMNS-ASTM A500 Gr.B(Fy=42,000 PSI)
<br /> HSS RECTANGULAR COLUMNS-ASTM A500 Gr.B(Fy=46,000 PSI)
<br /> ALL OTHER STEEL-ASTM A36(Fy=36,000 PSI)
<br /> STRUCTURAL STEEL WELDING
<br /> 1. CONFORM TO THE AWS CODES D1.1 AND D1.3.,AND USE ONLY CERTIFIED WELDERS.WELDS NOT
<br /> SPECIFIED ARE TO BE 1/4°CONTINUOUS FILLET MINIMUM.USE DRY E70 ELECTRODES.
<br /> ALTERNATES:
<br /> 1. ALTERNATE ASSEMBLIES AND MATERIALS WILL BE CONSIDERED FOR REVIEW.ENGINEER MAY REQUEST
<br /> PAYMENT FOR REVIEW;CONTRACTOR WILL BEAR BURDEN FOR ADDITIONAL PAYMENT AT NO ADDITIONAL
<br /> COST TO OWNER. In
<br /> LLI
<br /> H
<br /> JOBSITE SAFETY: 0
<br /> 1. THE ENGINEER AND/OR ARCHITECT HAVE NOT BEEN RETAINED OR COMPENSATED TO PROVIDE DESIGN Z
<br /> AND/OR CONSTRUCTION REVIEW SERVICES RELATED TO THE CONTRACTOR'S SAFETY PRECAUTIONS OR
<br /> TO MEANS,METHODS,TECHNIQUES,SEQUENCES OR PROCEDURES FOR THE CONTRACTOR TO PERFORMCe
<br /> HIS WORK.THE UNDERTAKING OF PERIODIC SITE VISITS BY THE ENGINEER AND/OR ARCHITECT SHALL
<br /> NOT BE CONSTRUED AS SUPERVISION OF ACTUAL CONSTRUCTION NOR MAKE HIM RESPONSIBLE FOR HU
<br /> PROVIDING A SAFE PLACE FOR THE PERFORMANCE OF WORK BY THE CONTRACTOR,SUBCONTRACTORS,
<br /> SUPPLIERS OR THEIR EMPLOYEES,OR FOR ACCESS,VISITS,USE,WORK,TRAVEL,OR OCCUPANCY BY ANY Ce
<br /> H
<br /> PERSON. (I)