Laserfiche WebLink
i / G 50'-0" / GENERAL UNIT PLAN NOTES 1111.1.1 <br /> u4 / 13'-9 x 6-9 / T-5 7 T 5 0 2 6 / 11 8' i/ <br /> 1. LEVELS 2-6:TYPE V-A <br /> 4 7C y TOWEL BAR 5 01lC / 7C 1 7nC ALL LEVELS FULLY SPRINKLERED PER NFPA 13. <br /> • 26 - - \ \ y BLOCKING 555SS VERIFY l Y _ \ , 2. SEE SHEETSA040-A041FORFIRE-RESISTIVEASSEMBLYTYPES JOHNSON BRAUNDmc <br /> 3 I TYPICAL WALL TYPES: 15200 52nd Ave.South <br /> WALL MOUNTED, ,_,F _f L 1 .�,I C \\` F LEVELS 2 TO 6-TYPE V-A CONSTRUCTION Suite 300 <br /> �' FOLDING ROLL-IN I in IA C�1U � Seattle,WA98188 <br /> 21. 1 SHOWER SEAT. 1` 11 1 , N �_�� c' _ 1 -`� REF. 7C CORRIDOR WALL Phone 206.766.8300 <br /> TOWEL BAR / `'� 1912 `Y'�LL w+.w.ionnwnbrauna corn <br /> ,II -CONTROLS _ BLOCKING �� i _ 72 �5. 7A EXTERIOR WALL <br /> ., P <br /> .. ^ �I, � 1: �c�r,� 1:. s m - M�i1TH n / -14�► 10 I ARCHITECTURE <br /> �I• 2 ) tn 8 �7 A14q lily., I OI - UNIT DEMISING WALLS INTERIOR DESIGN <br /> ' -``-` AM _ I h 17 \B 1 o-- -'4'-11 l , I 4- 'i A140 11 7B INTERIOR WALL(NON-LOAD BEARING) Greg L A1Nnne, <br /> 0 , Jeffrey A.Williams. <br /> 1°1' .I'4 r� .- <br /> 'Is 0 9 M 6 (4 t KRCHE P 1 B1 INTERIOR WALL(LOAD BEARING) <br /> J // F <br /> ar �I -_ • S f KITCHEN WORK f___`___f' 3. REFER TO OWNER PROVIDED FINISH 8 FIXTURE SCHEDULES. <br /> -"- --r V'r",- -^.- ____ p �' _ — - I.> H SURFACE PER IOC J/ 7D <br /> to TYPE BATHROOM-RIS/ ,7 TYPE'A'BATHROOM-RIS =_I.:•.• -RIS® _ •:••„ PE A RI S`P A117.1 AND CITE q_ x DOOR TYPE-SEE DOOR SCHEDULE ON SHEET A100 <br /> _�.-�1/"= NIT4. P' UNR 4.3��-� 1/4"=1 �,,UNR4.3�,,�,,,�,,__7J4"r,1'-q J,�JUNIT 4..-- s -SAP_ -"WA SECTIONTHE E003.12.3 O <br /> "'��� 1 �_ S. O WINDOW TYPE-SEE UNIT WINDOW SCHEDULE ON SHEET A100 <br /> - LF- __ 7z 1_- \II al �qlli i - III r L • P Z i 6. ALL UNITS ON AN ACCESSIBLE STORY SHALL COMPLY WITH WASHINGTON STATE <br /> - -,-� - - ,- '-',-- \ 1 (ICC/ANSI 117.1)"TYPE B".SEE FLOOR PLANS FOR LOCATIONS. <br /> 7A NI �'- t -� 4I 8 D s'\ FIVE PERCENT OF TOTAL NUMBER OF UNITS ARE DESIGNATED AS'TYPE A"UNITS <br /> ®� } I TOWEL BAR Y - - 1 ' d I -fib SEE SHEET AO20 FOR TYPE A CALCULATION.SEE FLOOR PLANS FOR LOCATIONS g556 <br /> ( ® BLOCKING , ,9, m „mu <br /> ` C.. ___ S+P r r 2 u T-5' SEE UNITSHEETS FOR"TYPEA"T A550PE B"UNIT PLANS. REGISTERED�liiii fly - / I I �+ SEE ACCESSIBILITY NOTES SHEET A550 ARCHITECT` , �� �I, - Bias <br /> (J �'-6-T 6'-0" '6-1" 5'-: 4'-6• I 4'-0" \ SEE SHEET A550 FOR ACCESSIBLE DETAILS <br /> 0'z.�l� �ti�>: n 1i ---_ - �i --- -CARP NYL> 1 ,1 > � �'. n <br /> 11 <br /> —_�� __ fw51. s r ��W` (7 "' 7. REFER TO SEPARATE ELECTRICAL&MECHANICAL DRAWINGS veacY aknit'n NtLUAv <br /> 4�y /�� STATE OF WASHINGTON <br /> l ERED SUBMITTALS) <br /> b7 }LIE �V,�� ( X - KS \\J/ 0.,' <br /> �'�, •/ (DOFF HARDWIRED SMOKE/CO DETECTOR WI BATTERY BACK-UP <br /> `TP HOLDER I` IsTAuv <br /> : ' ` Q EXHAUST FAN DRYER VENT <br /> b O O• OO LIVING g, <br /> BLOCKING vw1�•� WHOLE HOUSE FAN PER IMC REQUIREMENTS <br /> o , <br /> In z <br /> ggs <br /> 14 TYPE'A'BATH 13 TYPE'A'BATHR9R 1 12 TYPE'A'BATH- •�• _ M ru POWER VENT WILL BE REQUIRED FOR DRYER E E ' <br /> UNIT 4.2� U IT4.2� � + I EXHAUST LENGTHS THAT EXCEED MANUFACTURER'S <br /> 1 1 1 BEDROOM 1 1 BEDROOM 2 BEDROOM 3 SPECIFICATIONS.SEE MECHANICAL. <br /> Kt &\ C - <br /> I 1 8 __ INDICATES LOCATION OF IXHAUST DUCTING m <br /> • <br /> FILLER 30" 18" 36" 36" 24" ILLER 34" 30" 36" 15" FILLER FOR DUCTS WITHIN JOIST SPACE-SEE DETAIL "®^ <br /> 10'-8' Y-4'11 9'-10" 10'-8" ib'-8" 4" - <br /> I�I���� ��IIMI` / /I / ,.( VENT THROUGH ROOF @ 6TH FLOOR co 3 f <br /> }■�,=-- SOFFIT JJKiy SOFFIT I I 1 9 INDICATES LOCATION OF DROPPED SOFFIT Pell - ' <br /> �.�, �IB � �� O /) B < @ T-0"MIN.SEE DETAIL v i <br /> •3 ��- -�'� ■■'� a• � ���I m \ \ \ 1�7�JI N r.1,— <br /> j II r -I •1 _ r T� 10 ALL EXHAUST VENT TERMINATIONS MUST BE3FEET CLEAR FROM ANY <br /> //�� OPERABLE OPENING INTO THE BUILDING,AND 10 FEET CLEAR FROM <br /> - �',/F �' h "L ANY MECHANICAL AIR INTAKE.GANG TERMINATIONS TOGETHER UNDER <br /> �� 1 __ ' .- / - 7A' I �7J I, 5'-2' S-10" ONE SHROUD,AS POSSIBLE. <br /> CUD <br /> 4. <br /> ry� l�lo'L� i7V I�B� ❑y '-71" 5'-3' �t DECK `O e <br /> IMfil . KS 7A Jr.' / / Ct H Aa <br /> m ��Iw.. . AREA ry I 113 4_ ❑ 13. REQUIRED CLEAR FLOOR SPACES AS SHOWN ON PLANS:REFER <br /> FILLER 30" cm 36" 24" ILLER 32 , 36" FILLER I I \ ALSO TO ACCESSIBILITY NOTES SHEETS A550. w <br /> CONES'ISLE �, �, 73'-10" P'T' 4-13/4/ i i 317X46'CLR.FLOOR SPACE AT FIXTURES 8 <br /> CONTROLS sg <br /> t1 TYPE'A'KITCHEN mi , j'-8-„, 10-8" / / 1 (CENTERED)8 ONE AREA FREE OF DOOR SWING IN BATH <br /> 1f4"=1'-0" 1/4"=1'-0" _ -._ - _- ._ WOOD / E----11 49"X46'CLR.FLOOR SPACE AT ENTRY DOOR PUSH SIDE-ALL <br /> 1 I UNITS o I R <br /> 1 I 54"X6"CLR.FLOOR SPACE AT PULL SIDE OF ALL PASSAGE e i <br /> (2 }FDROOM UNIT-TYPEA L____JJ DOORS-TYPE A UNIT ONLY ; <br /> • u <br /> / Q 50-0" �, 60'MANEUVERING CIRCLE-TYPE A UNITS ONLY <br /> / 13'-9' -1-,-> / 6'-9" / 1D-0- 5' 0" 2' 6"/ 12' 0" '. .' o' <br /> TOWEL BAR 5'-01/2" T-5' 1'-E t;2' Ti _ <br /> © / / / --Y-,-f' j 7C 14. CONTROLS,FAN WALL SWITCH 8 OUTLETS TO BE WITHIN REAC m E <br /> BLOCKING VERIFY Q <br /> -,,,-\--"' BLOCKING RANGES-SEE ACCESSIBILITY NOTES SHEET A660 8 DETAIL o <br /> — <br /> © 2" �' 2" _ T _ ‘ L_7 _. is. FOR TUBS AT FIRE-RATED WALL AND FLOOR ASSEMBUES-SEE Mk Allak g <br /> __ <br /> MIRRO <br /> I O m 8 o-r_/� 3 17 S+P=SHELF 8 POLE.CLOSET SHELF 8 POLE IN TYPE A UNITS TO SE (A <br /> I p 6 A7�sI B': s ADJUSTABLE TO BE WITHIN REACH RANGE 48"MAX.AFF. 4•+ P <br /> I ,�'� ER " A �-.7,r __� . A "-./ti--ti�- 4•-6• _ RA�7dEi <br /> +,. - tS1 \S`" w a/-lg-_ $- 4—VERIFY <br /> 4.-`i I A3 4 C,I�. � <br /> I` its—C _�� 11[1, YAST b ®M•BATH - VERI m ,OPTION r Er �4 1',\ \ 7D E 5 <br /> mud � _ IP <br /> �m�:J = CARPET q NYL �- �,° N > I IS.P N h f UNIT INTERIOR ELEVATION NOTES gC£ <br /> 17" �" 7L'i ) - ' —I1 1. DIMENSIONS ARE TO FACE OF G.W.B(NET).UNLESS NOTED OTHERWISE. <br /> SOP <br /> �2 . 2. FIELD VERIFY ALL FINISHED DIMENSION PRIOR TO ORDERING CABINETS mo i <br /> /� 7A \ • s j_==o I l-, AND COUNTERTOPS. Q <br /> / ' TYPE'B'BATHROOM TYPE'El'BATHROOM I 0 4 3. PROVIDE BLOCKING AT TOILET PAPER HOLDERS,TOWEL BARS,DOOR `WI. e <br /> 1/4"=1'-0' 1/4"=1'-0" _ I / 0 t I STRIKES,DRAPERIES,REMOVABLE CABINET SUPPORTS&GRAB BARS. L a 3 S A <br /> �J <br /> a 1 i i 8� W 11 = DW I 4. TYPICAL CABINET SYSTEM PROFILE,SEE DETAIL A550 $ <br /> 0� 1.,. -,._- -, 1. ,--„-- -Y- ,.,I /" W V. <br /> m i <br /> •E 4' © 2 ,'I: wI \ I D_- i— I� IF 1 ``--'- `^ '"`^'- 2'-s I KITCHEN KEYNOTES BATH KEYNOTES LO m W Q U it A ; <br /> D TOWEL BAR MIRROR b tO M.CLOSET } 8 / 8 / Ci / U J 25 4 <br /> BLOCKING m 1 I S+P a K7 CONCEAL DUCT AT RANGE HOOD b1 gCCESSIBLE LAVE.SINK AND V w Ii m c$ i <br /> COUNTER-TYPEA88 <br /> • 1'•8' 8'-0• 6-t" L 5- 4'-6" 4'-0'c - O EXHAUST,SEE UNIT PLANS FOR O L ❑ m� u <br /> W - i_ `,. J' / - - / I --- / ✓ B+P s EXTENT OF DROPPED SOFFIT. UNITS-SEE v ❑ W C w m <br /> / CARPETd:(VINYL <br /> Z - (� `� ,�' I `�- - s > 7 CABINETS Wf ADJUSTABLE SHELVES D2 OPEN KNEE SPACE FOR r z❑o <br /> ` r _�/ `- O ACCESSIBLE BATHROOMS IN ITY SINK AT ALL v LL m O al m EE <br /> ��� --� r \ tTlg <br /> 4 —1 4 PER FINISH SCHEDULE. <br /> �i\ , �� TYPE A UNITS.EXTEND <br /> O �S1ti l - Qj-1 N AI,= a a K3 COUNTERTOP 8 BACKSPLASH PER pROVIDE GRAB BARS <br /> • 1 v_ O OWNER SPECIFICATIONS. FLOORING UNDER-SEE <br /> •_- b7_- _ Eiff x Dam ■�/ 'E b3 ADAPTABLE FEATURE FOR <br /> L• \ ::/// El-- <br /> O 7 ` O• •O la� ACCESSIBLE WATERCLOSET <br /> E TP HOLDER Q �0 ` ■ Q TYPE B UNITS,AND 5 <br /> D BLOCKING 1 I ADAHAN COMPLIANT FAUCET W/LEVER INSTALL GRAB BAR 5 TYPE <br /> U p N m KS HANDLE(ALL UNITS) A UNITS-SEE <br /> 7 TYPE'B'BATyR(a� ��TYPE'B'BAT('./IR ( 5 TYPEB'_BA BEDROOM 1 BEDROOM x �" BEDROOM 3 VABLE CABINET(ADAPTABLE b4 PROVIDE GRAB BARS <br /> t2 1/4"=V-0" „p ILON g, 1/4"=I-0" (OPT910N�A 1/4"=1,0" pu pT�p�g� 7- tiles / ,L m O FEATOURE)Q OPEN KNEE SPACE OR O ADAPTABLE TUB RE FOR <br /> SHOWER PE B <br /> N - II SINK AND LOWERED WORKSPACE Q UNITS AND INSTALL GRAB O <br /> 00 70-T 2'-4" 34"MAX.AFF TO SINK RIM/27"MIN <br /> FILLER 30'1 30" 24" 38" 24" FILLER FILLER 34' 30" 38" 75" FILLER 1' 4" KNEESPACE-EXTENDFLOORING BAR®TYPEA UNITS-SEE <br /> 1 UNDER D5 MIRROR-40'A.F.F.MAX TO <br /> oRt��D_�i, M�M�MM��e I f <br /> �IMMMMl1 QT� SOFFIT <D/� i p B 1 I (TYPE A ACCESSIBLE UNITS ONLY) O BOTTOM EDGE OF <br /> SOFFIT O F `�tF REFLECTING SURFACE. <br /> ❑ \ \ R H H 9,I, Al . I�;�IM� 2 K7 BLIND CORNER CABINET <br /> IIMEMME15111 <br /> rIIIIIIII * `,� wl B .� .L �- MICROWAVEB HOOD PER OWNEROBBAURFACE MOUNTED LIGHT PROJECT#: 1827 <br /> �� a m \ \ �i E Di m 5'-2" 5'-10" I O SPECIFICATION b7TU885URROUND PERDRAWN BY: AT <br /> C� � L.r 6-0• II I / `16 O OWNERSPECIFICATION. CHECKED BY: ST <br /> .I�.� 5 6-3" 1 RANGE W/FRONT CONTROLS_ m� �M111.11..111" � mFgal m 1gKII -1 3/4f O (TYPE AACCESSIBLE UNITS ONLY) O WIRE SHELVING <br /> O � • — i' RANGE HOOD ONLY.PROVIDE WALL 4 BEDROOM PLANS& <br /> PLASTICM� .� <br /> M__ I SWITCH AT 46"MAX.AFF.PROVIDE LAMINATECOUNTERTOP& ELEVATIONS <br /> O <br /> U '� ip,.rr�MI_� m �� - - 1• COUNTERTOP MICROWAVE(TYPE A BACKSPLASH PER OWNER <br /> \ � �' � 10-6" f_ 12'-6" J' P.T. / ACCESSIBLE UNITS ONLY) SPECIFICATION. _ <br /> FILLER r t24" 36" 24" FILLER <br /> ��e � I, 30' 36" FILLER - - - 11 ADA COMPLIANT REFRIGERATOR SPECIFICATION. <br /> 4 '( T'f el WOOD MAX54'HTAFFTOFREEZER VANITYCABINETSOWNER A140 <br /> I.i- '_ . . . / ' 1 TYPE'B'KITCHEN Ap�®i MIN.20 GA.STAINLESS STEEL <br /> 0 1/4".1,0" 1/4"=1,0" 11 4 BEDROOM UNIT-TY-E B(OPTION B BAT. L, KITCHEN SINKN CONSTRUCTION SET <br /> T. 09/01/2021 <br /> ,UNIT4.1 A <br />