Laserfiche WebLink
II II <br /> NA EX I CAN IR E 9-TAU RANT N <br /> J m0 <br /> -I ¢m <br /> W -> <br /> cck? <br /> T. <br /> I-U '' <br /> FL W 0°"F <br /> 52 <br /> I_ Dia° <br /> wL'm <br /> = <br /> a U 01m <br /> GENERAL NOTES SHEET INDEX PROJECT TEAM a v Q <br /> •�N <br /> CIVIL OWNER w 2 air• <br /> 1.THESE GENERAL NOTES PERTAIN TO WORK DESCRIBED ON ALL CONTRACT DOCUMENTS. 1y <br /> C 1.1 CIVIL XT O 3FN <br /> 2.THE CONTRACT DOCUMENTS CONSIST OF THE OWNER CONTRACTOR AGREEMENT,THE CONDITIONS OF CONTRACT x a f' was <br /> (GENERAL,SUPPLEMENTARY,AND OTHER CONDITIONS),THE DRAWINGS,THE SPECIFICATIONS,AND ALL ADDENDA ISSUED - -- ak �J to°D3 <br /> PRIOR TO AND ALL MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT. ARCHITECTURAL GENERAL CONTRACTOR - <br /> 3.CONCEPT ARCHITECTURE,LLC IS THE AUTHOR OF THESE PLANS AND CLAMSA COPYRIGHT IN THESE PLANS AND THE AD1 TITLE SHEET X P. PROPERTY INFORMATION t-o � <br /> DESIGNS CONTAINED IN THESE PLANS.THIS CLAM IS MADE UNDER TITLE 17 OF THE UNITED STATES CODE AND ALL APPLICABLE 'O <br /> TREATIES AND FOREIGN LAWS.THESE COPYRIGHTED DRAWING FILES ARE TO BE USED FOR REFERENCE ONLY.CONCEPT A0.2 CODE ANALYSIS/EXITING PLAN X XXX@VYV,COM ¢ <br /> ARCHITECTURE,LLC WILL TAKE NO RESPONSIBILITY FOR ANY CHANGES MADE TO THESE DOCUMENTS BY ANOTHER PARTY AND AT.1 SITE PLAN a.:: <br /> NO LICENSE IS GIVEN FOR TRANSFER OF THESE COPYRIGHTS TO ANOTHER PARTY. A2.0 DEMOLITION PLAN ARCHITECTURAL ADDRESS X ry <br /> 4.THE WORK COMPRISES THE COMPLETED CONSTRUCTION REQUIRED BY THE CONTRACT DOCUMENTS AND INCLUDES ALL A2.1 FLOOR PLAN - APN X - S <br /> A6.1 REFLECTED CEILING PLAN CONCEPT ARCHITECTURE,LLC. P.(925 <br /> LABOR NECESSARY TO PRODUCE SUCH CONSTRUCTION,AND ALL MATERIALS AND EQUIPMENT INCORPORATED OR TO BE )377.8786 SIZE X -¢ <br /> INCORPORATED IN SUCH CONSTRUCTION. A7.1 ROOM FINISH SCHEDULE 2615 W.CASINO RD.SUITE 1A PE <br /> EVERETT.WA 98204 MREIMERS@CONCEPTARCHITECTURE.COM SUBDIVISION X <br /> 5.SHOP DRAWINGS,PRODUCT DATA AND SAMPLES ARE NOT A PART OF THE CONTRACT DOCUMENTS.THE ARCHITECT WILL ZONE X 'n <br /> REVIEW THEM,BUT ONLY FOR CONFORMANCE W RH THE DESIGN CONCEPT OF THE WORK AND WITH THE INFORMATION GIVEN CIVIL IN THE CONTRACT DOCUMENTS.THE CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITY FOR ANY DEVIATION FROM a p <br /> THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE ARCHITECTS REVIEW OFSHOP DRAWINGS,PRODUCT DATA OR X P: <br /> SAMPLES. PROJECT DESCRIPTION �� <br /> x <br /> 6.THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS AND SHALL AT ONCE REPORT TO X XXX@YYV.COM ¢O <br /> THE ARCHITECT ANY ERROR.INCONSISTENCY OR OMISSIONS HE MAY DISCOVER.THE CONTRACTOR SHALL PERFORM NO 0- <br /> PORTION OF THE WORK AT ANY TIME WITHOUT CONTRACT DOCUMENTS OR,WHERE REQUIRED.APPROVED SHOP DRAWINGS, STRUCTURAL PROJECT DESCRIPTION <br /> PRODUCT DATA OR SAMPLES FOR SUCH PORTION OF THE WORK. <br /> 7.ALL WORK IS TO CONFORM WITH THE CONTRACT DOCUMENTS.DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION IF X P. w <br /> UNABLE TO LOCATE DIMENSIONS FOR ANY ITEM OF WORK,CONSULT WITH THE ARCHITECT BEFORE PROCEEDING WITH STRUCTURAL X XXX@YYY COM ¢A <br /> CONSTRUCTION. <br /> S,, STRUCTURAL MECHANICAL 8.IN THE EVENT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN ON THE CONTRACT DOCUMENTS.THEN v¢i o¢ <br /> THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR CALLED FOR CODES o a <br /> AND SHALL BE REVIEWED BY THE ARCHITECT. X P. <br /> 9.ALL WORK SHALL BE PERFORMED WITHIN STRICT CONFORMANCE TO THE MINIMUM STANDARDS OF THE CURRENT EDITION X XXX@YYY.COM EDIT "' <br /> OF THE INTERNATIONAL BUILDING CODE AND ALL APPLICABLE NATIONAL,STATE.AND LOCAL LAWS,REGULATIONS AND MECHANICAL PLUMBING om <br /> ORDINANCES. BASED ON THE FOLLOWING CODES ¢ <br /> M1.1 MECHANICAL 2018 International Building Cale V. <br /> 10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE GENERAL SAFETY DURING CONSTRUCTION,AND ALL WORK SHALL X P. 2018 International Residential Code <br /> CONFORM TO PERTINENT SAFETY REGULATIONS. X 2018 International Mechanical Cale - <br /> 11.THE CONTRACTOR SHALL COORDINATE LOCATIONS OF ANY AND ALL MECHANICAL,TELEPHONE,ELECTRICAL LIGHTING AND X XXX@YYY.COM 2018 Warhington Slate Energy Code o <br /> PLUMBING 2018 International Fire Code o <br /> PLUMBING INCLUDING ALL PIPING,DUCT WORK AND CONDUIT.COORDINATE ALL REQUIRED CLEARANCES FOR INSTALLATION 2016 Uniform Plumbing Code <br /> AND MAINTENANCE OF THE ABOVE EQUIPMENT. ELECTRICAL 2020 National Electrieal Code OF v, <br /> 2018 Washin 1 Amendments E <br /> 12. P1.1 PLUMBING SIA <br /> SOLELY <br /> COSP SHALLOR CONSISE TRUCT DIRECTTHE WORK S ECHIS/HER,EST SEQUENLL ANDCES <br /> ATTENTION,OCDHE/SHE SHALLBE X p; 2009ICC/ANSI A117.1 <br /> SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS,METHODS,TECHNIQUES,SEQUENCES AND PROCEDURES AND FOR X L <br /> COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. X XXX@YYY.COMI- <br /> - <br /> 13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACTS AND OMISSIONS OF HIS/HER EMPLOYEES,SUBCONTRACTORS ¢0 Z <br /> AND THEIR AGENTS AND EMPLOYEES,AND OTHER PERSONS PERFORMING ANY WORK UNDER A CONTRACTWTTH THE ELECTRICAL DEFERRED SUBMITTALS N Q <br /> CONTRACTOR. r <br /> E1.' ELECTRICAL w o <br /> 14.THE CONTRACTOR SHALL PURSUE WORK IN A CONTINUOUS AND DILIGENT MANNER TO INSURE TIMELY COMPLETION OF THE SYMBOL LIST =TI cc <br /> PROJECT. OCCUPANCY GROUP X p- D co <br /> 15.THE CONTRACTOR AT ALL TIMES SHALL KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS OR FLOOR AREA X S.F. Q Q <br /> RUBBISH CAUSED BY HIS/HER OPERATIONS.AT THE COMPLETION OF THE WORK,HE/SHE SHALL REMOVE ALL HIS/HER WASTE NORTH ARROW \\X//1I WOOD FRAMING t- <br /> MATERIALS AND RUBBISH FROM AND ABOUT THE PROJECT AS WELL AS ALL HIS/HER TOOLS.CONSTRUCTION EQUIPMENT. 1.1111k �I�NOFITH^ I/ V (THROUGH MEMBER) ., ASPHALT FULLY SPRWKLERED X it''' <br /> i `�n <br /> MACHINERY,AND SURPLUS MATERIALS. Y V OVERALL OCCUPANT LOAD X ¢ v J <br /> YYYY I/I (INTERRUPTED MEMBER) S/II�IIIV1IU`IIIVIt�I BATT INSULATION S D w <br /> 16.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND/OR PROTECTION OF ALL EXISTING AND PROPOSED �+ PROPERTY CONSTRUCTION TYPE X 11 <br /> W <br /> PIPING,UTILITIES.STRUCTURES,ADJACENT STREETS.AND IMPROVEMENTS DURING THE PERIOD OF CONSTRUCTION. `� CORNER CEIUNG HEIGHT //////// BRICK >: <br /> 17.UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS,THE CONTRACTOR SHALL PROVIDE AND PAY FOR ALL _p pF'F' SPOT ELEVATION +O1-On <br /> LABOR,MATERIAL.EQUIPMENT,TOOLS.CONSTRUCTION EQUIPMENT,MACHINERY,WATER,HEAT,UTILITIES,TRANSPORTATION, <br /> 12 ' CMU BLOCK Z <br /> AND OTHER FACILITIES AND SERVICES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. LEVEL ELEVATION 31 <br /> - ROOF SLOPE r¢ �l m <br /> 0'-0' N <br /> 18.WHERE CONFLICTS OCCUR,COORDINATE THE LAYOUT AND EXACT LOCATION OF ALL PARTITIONS,DOORS,TELEPHONES L SLOPE ROOF SLOPE PLAN CONCRETE 0 rn <br /> AND ELECTRICAUCOMMUNICATION OUTLETS AND SWITCHES WITH ARCHITECT IN THE FIELD BEFORE PROCEEDING WITH N <br /> CONSTRUCTION. © BUILDING SECTION C3-12� DOOR SYMBOL - - - E.I.F.S. X LE <br /> O <br /> 19.WHERE CONFLICT IS ENCOUNTERED BETWEEN THE CONTRACT DOCUMENTS THAT WILL MATERIALLY AFFECT THE QUALITY CUT Q WINDOW SYMBOL GRADE(EARTH C CO <br /> OR EXTENT OF THE WORK,SUCH CONFLICT SHALL BE RESOLVED TO THE SATISFACTION OF THE ARCHITECT BEFORE THE ® CO <br /> AFFECTED ITEMS AND/OR MATERIALS ARE PURCHASED,FABRICATED AND/OR INSTALLED. © U <br /> WALLSECTION CUT 12 ACCESSORY SYMBOL i,..:s~. .i GRAVEL VICINITY MAP <br /> 20.WHERE PRE MANUFACTURED OR PREFABRICATED ITEMS AND/OR MATERIALS ARE TO BE INSTALLED-THE CONTRACTOR VW <br /> SHALL VERIFY ROUGH OR FINISHED DIMENSIONS IN THE FIELD PRIOR TO PURCHASE OR FABRICATION. /72` _ GYPSUM BOARD LLI <br /> PROJECT LOCATION cc <br /> © DETAIL CALLOW' / \ CRONTOURDLINE 21.THE CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS TO BE FREE FROM DEFECTS FOR A MINIMUM OF ONE Z 12 <br /> YEAR FROM DATE OF FINAL ACCEPTANCE,AND PROMPTLY REMEDY SUCH DEFECTS AND ANY SUBSEQUENT DAMAGE CAUSED Vir 72 GYPSUM SHEATHING U <br /> BY THE DEFECTS OR REPAIR THEREOF,AT NO EXPENSE TO THE OWNER.GUARANTEE PERIODS OF GREATER THAN ONE YEAR ( ) CXONTOUR LINE 0 <br /> F <br /> a. <br /> MAY BE REQUIRED AND CONTAINED WITHIN THE CONTRACT DOCUMENTS. 1 ORIENTED STRAND = <br /> PROPERTY LINE FS"G, BOARD 0 <br /> 22.UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL SECURE AND PAY FOR THE 2 A°.1 4 ELEVATION BUBBLE <br /> BUILDING PERMIT AND FOR ALL OTHER PERMITS AND GOVERNMENTAL FEES,LICENSES AND INSPECTIONS NECESSARY FOR THE A MATCH LINE ;////////// PLYWOOD SHEATHING Q O <br /> PROPER EXECUTION AND COMPLETION OF THE WORK. D F 5 <br /> 23.WHERE ANY ITEM AND/OR MATERIAL IS INDICATED IN THE CONTRACT DOCUMENTS,AND NOT NECESSARILY DETAILED IN NAME B .--- CENTERLINE I I I I I I I I I I I RIGID INSULATION LU ¢ <br /> EACH SPECIFIC CASE,BUT IS REQUIRED FOR A COMPLETE AND PROFESSIONAL INSTALLATION-SUCH fTEM AND/OR MATERIAL I� L- U - <br /> SHALL BE PROVIDED AS IF SHOWN AND DETAILED IN FULL PROVIDE MEANS TO FURNISH AND INSTALL I ( NUMBERU NAME B ?c',:;yy:•.:...,,:;,' SAND T MORTAR/ • ^ Z r <br /> - PIi-PH- PHONE LINE -_ (J) <br /> REVISION CLOUDS -G_G- GAS LINE /��///��� STEEL O m o <br /> NUMBER <br /> TIL_ ElCARPET CHANGE IN <br /> FLOOR _E-E_ ELECTRICAL UNEWE= STONE 0 N a <br /> 7 <br /> U < <br /> -X-X- FENCE LINE I/ll)YIII(IIIYIII/IYlll4 TECTUM CD IT 2 <br /> A I5 0 <br /> SS-SS SANITARY SEWER Z WOOD FINISH IL I- ao <br /> ¢ o <br /> a <br /> 4- GRID LINES -Tv-TV TELEVISION UNE GLASS O H a CV N T <br /> -W-W- WATERLINE 0 2 2 ENZ 2 ' r < 5 <br />