My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2115 15TH ST 2022 Plans 2025-07-08
>
Address Records
>
15TH ST
>
2115
>
Plans
>
2115 15TH ST 2022 Plans 2025-07-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2025 8:56:17 AM
Creation date
7/8/2025 8:56:06 AM
Metadata
Fields
Template:
Address Document
Street Name
15TH ST
Street Number
2115
Permit
B2209-018
Year
2022
Notes
ADD DECK TO FRONT OF SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. _°.. 1.--(--.- <br /> a service of eCityGov.net Construction Tip Sheet 05 <br /> Deck Construction Notes <br /> • Design loading for decks is based on 60 pounds per square feet (PSF) live load, 10 PSF dead <br /> load, and 1500 PSF soil-bearing capacity. <br /> • The illustrations and information in this tip Sheet may be used for decks whether or not they <br /> require a permit. See Tip Sheet 0 for when a permit is required. <br /> • All wood must be pressure-treated or naturally resistant to decay. Treat cuts, holes, and <br /> notches with end-cut solution. <br /> • Fasteners, hangers, nails, etc., must be stainless steel, hot-dipped galvanized, or as specifically <br /> required for the specified wood preservative used. The coating weights for zinc-coated <br /> fasteners to be in accordance with ASTM A 153. Provide documentation in the field showing <br /> the required fastener protection for the wood chosen for your deck. <br /> • You may modify any components of this Tip Sheet using accepted engineering practices. Any <br /> modifications must be reviewed prior to permit issuance. All attachments must be per <br /> manufacturer's installation instructions. <br /> • Visit MyBuildingPermit.com for additional Tip Sheets for stairs, handrails, and notching and <br /> boring. <br /> 36"minimum high guard <br /> with intermediate rails Attachment of <br /> spaced so that a sphere i pre-manufactured guardail <br /> systems to deck components <br /> 4"in diameter cannot <br /> Existing building shall be per manufacturer. <br /> pass through(See Tip Special blocking details may be <br /> _...77Flashing Sheet 3). required by the reviewer. <br /> See detail 1 on page <br /> Sheet <br /> for ledger Refer table on page See page 8 for guardrail <br /> 4 attachment options 3 for Joist Sizes post connection <br /> Decking and Spans <br /> — <br /> 1 Secure ballusters with(1)#8d <br /> ( / wood screw top&bottom <br /> / 3f4"spacing \ Refer to Table on page 3 for <br /> recommended Beam Size and Spans <br /> Note: for drainage <br /> Contractor to field Knee braces are required if <br /> verify adequacy of f distance from grade to top of <br /> solid lumber for ledger post exceeds 48". See detail <br /> connection. If an exit or egress from " on page 7 <br /> / the existing building <br /> d passes under the For post size and maximum <br /> proposed deck,or if there allowable height,see page 4 <br /> Is an existing patio under <br /> the proposed deck,6'-8" <br /> minimum clearance must <br /> be maintained. Please <br /> Indicate openings In Manufactured post base cast In <br /> existing wall in elevation footing <br /> view. <br /> Refer to Table on page 4 for <br /> Footing Size <br /> 3,000 psi concrete(no special <br /> inspection required) <br /> r Finished grade <br /> 1"dear—, I— <br /> Minimum I 1 't•= _ I ` (2)#4 ea.way,3"clear <br /> I I I I I1•:'. : Ip1 to bottom of footing. <br /> depth of I :: ," III Footing to bear on <br /> footing 12" i I—Piii 1 1 1 =undisturbed earth. <br /> January 14,2022 MyBuildingPermit.com i Basic Deck <br /> eCttyGov net <br /> 2005 alk011YGa 11$rice <br />
The URL can be used to link to this page
Your browser does not support the video tag.