Laserfiche WebLink
GENERAL REQUIREMENTS SOILS AND FOUNDATIONS <br /> Y S. F <br /> • Refer to subsequent plan and detail notes for variations and requirements specific to referenced project. REFERENCE STANDARDS: S� F wASNtrtj�C <br /> Conform to IBC Chapter 18 "SOILS & FOUNDATIONS �� c>'� <br /> NOTE PRIORITIES: Notes on the individual drawings govern over notes on this sheet. «� 4i , .... S. "-a--4 <br /> DESIGN SOIL VALUES: 1 `-d ,C�/", <br /> SPECIFICATIONS: Refer to the specifications for information in addition to that contained in these notes .; SFAM1n Design Group. LLx <br /> and the structural drawings. Allowable Foundation Pressure (assumed) 1500 PSF ,.dam 4'd '40,..$) <br /> w� V Vi,03UC I U RGE ENGINEERRING Nl <br /> PUSH PIERS/PIN PILES °A��'', T �9 w <br /> STRUCTURAL DETAILS: The structural drawings are intended to show the general character and extent of MATERIALS: ,,, L ��G <br /> the project. They are not intended to show all details of the work. Details noted "typical" apply to Bracket Plates - ASTM A36 <br /> similar work throughout the project unless noted separately. <br /> (Min Yield Stress, Fy = 36 ksi / Min Tensile Stress, Fu = 58 ksi) EXPIRES: 12/24/24 . <br /> STRUCTURAL RESPONSIBILITIES: The structural engineer is responsible for the strength and stability of the Pier Tubes - ASTM A500 Grade B or C 0 <br /> primary structure in its completed form. (Min Yield Stress, Fy = 46 ksi / Min Tensile Stress, Fu = 58 ksi) Z <br /> External Sleeve - ASTM A500 Grade B or C 0 <br /> CONTRACTOR RESPONSIBILITIES: The contractor is responsible for the means and methods of construction (Min Yield Stress, Fy = 46 ksi / Min Tensile Stress, Fu = 58 ksi) C z <br /> and all job related safety standards (i.e. OSHA or Federally approved State plan). The contractor is Pier Cap - ASTM A36 Q z <br /> responsible for the strength and stability of the structure during construction. The contractor shall (Min Yield Stress, Fy = 36 ksi / Min Tensile Stress, Fu = 58 ksi) z <br /> a' <br /> provide temporary shoring, bracing and other elements required to maintain stability until the structure is Coil Rod - ASTM A193 Grade B7W CC <br /> complete. It is the contractor's responsibility to be familiar with the work required in the construction (Min Yield Stress, Fy = 105 ksi / Min Tensile Stress, Fu = 125 ksi) in CO <br /> CC 0 z N documents and the requirements for executing it properly. The contractor shall at his discretion employ Steel Angle Shapes - ASTM A36 z J <br /> a Washington State registered structural engineer for design of temporary bracing and shoring. It is the (Min Yield Stress, Fy = 36 ksi / Min Tensile Stress, Fu = 58 ksi) Z : W a <br /> contractor's responsibility to contact the Engineer-of-Record to schedule applicable Structural O W 0 Q <br /> Observations. WELDING NOTES: — 0 Cn <br /> Conform to AWS D1.1. Welders shall be certified in accordance with AWS requirements. Use E70 <br /> DISCREPANCIES: In case of discrepancies between the specifications, reference standards and the electrodes of type required for materials to be welded. Q W — ~ <br /> O = W <br /> governing code, the Engineer will determine which shall govern. Discrepancies shall be brought to the attention of the Engineer before proceeding with the work. CORROSION PROTECTION: Z (1)W 1- CC <br /> W <br /> Sacrificial Design Thickness - Capacities include a scheduled loss in steel thickness due to D II N <br /> SITE VERIFICATION: The contractor shall verify all dimensions and conditions at the site. Conflicts between corrosion for black, uncoated steel. Anchors are designed for 50-year scheduled sacrificial O Z W <br /> the drawings and actual site conditions shall be brought to the attention of the Engineer before thickness loss in accordance with ICC-ES AC358. 0 <br /> proceeding with the work. F <br /> INSTALLATION: > Y <br /> CONSTRUCTION LOADS: Loads on the structure during construction shall not exceed the design loads as System to be installed per manufacturers recommendations. Minimum installation pressure is to j Z <br /> noted in DESIGN REQUIREMENTS below or the capacity of partially completed construction. be determined by the following equation: > < <br /> H Ca <br /> ADJACENT UTILITIES: The contractor shall determine the location of all adjacent underground utilities prior Push Pier Installation Pressure (psi): Q <br /> to excavation and prior to drilling holes for piles. Any utility information shown on the drawings and [DESIGN LOAD] X 2 / [AREA OF HYDRAULIC RAM]. 2 <br /> details are approximate and not necessarily complete. <br /> Pin piles are to be driven to refusal. Installation refusal is considered to be <br /> ALTERNATES: Alternates for specified items may be submitted to the Engineer for review. reached when the energy from a 110 Ib pneumatic hammer no longer carries a <br /> vertical displacement of one inch movement observed in a one minute time <br /> DESIGN CRITERIA span to the pile. GENERAL NOTES <br /> Building Code Conformance (meets or exceeds requirements): Minimum Push Pier Installation Depth is 10'-0"± uno. <br /> Minimum Pin Pile Installation Depth is 10'-0"± uno. REVISIONS <br /> 2018 International Building Bode (IBC) <br /> 2018 International Residential Code (IRC) Notify engineer if minimum installation conditions cannot be achieved. <br /> 2018 Washington State Building Code <br /> 2018 Washington State Residential Code EXISTING UTILITY LINES: <br /> Contractor to repair utility lines that may be damaged during installation. <br /> DEAD LOADS: <br /> Roof Dead Load 15 PSF <br /> PUSH PIER/PIN PILE SPLICING: PROJECT NO: <br /> Floor Dead Load 15 PSF MFR23-336 <br /> Piles are to be gravity spliced with fitting couplers. Building weight will ensure joints do not DESIGNED BY: <br /> Wood Wall Dead Load 12 PSF CAF <br /> Interior Wood Wall Dead Load 9 PSF separate. <br /> DRAWN BY: <br /> Concrete 150 PCF TESTING & INSPECTION <br /> CAF <br /> CHECKED BY: <br /> CVR,JLD <br /> LIVE LOADS: Continuous Special Inspection is required during installation per 2018 IBC Section 1810.4.12. DATE: <br /> Roof Snow Load 25 PSF The Special Inspector is responsible for verifying and recording the following: 03.01.2024 <br /> Floor Live Load (residential) 40 PSF SHEET NO: <br /> • <br /> Project description (address, installation date, permit number) <br /> • Pile and bracket configuration S 1 1 <br /> • Part description (product manufacturer, bracket type, pier type, pier outside diameter, pier wall ■ <br /> thickness) <br /> • Pier inclination, location, depth, and installation pressure achieved <br />