2808 HOYT AVE 2022 ALIVE JUICE BAR / THE SOUP NAZI KITCHEN Plans 2025-07-08
>
Address Records
>
HOYT AVE
>
2808
>
ALIVE JUICE BAR / THE SOUP NAZI KITCHEN
>
Plans
>
2808 HOYT AVE 2022 ALIVE JUICE BAR / THE SOUP NAZI KITCHEN Plans 2025-07-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2025 11:18:23 AM
Creation date
7/8/2025 9:58:17 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2808
Tenant Name
ALIVE JUICE BAR / THE SOUP NAZI KITCHEN
Permit
E2201-170
M2202-092
Year
2022
Notes
INSTALLATION OF NEW SINGLE ZONE DUCTLESS HEAT PUMP
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIFICATIONS: MSZ-GS3ONA& MUZ-GS3ONA <br /> Maximum Capacity BTU/H 30,700 <br /> Rated Capacity BTU/H 30,600 <br /> Minimum Capacity BTUM 10,300 <br /> Cooling at 95°F' Maximum Power Input W 3,320 <br /> Rated Power Input W 3,320 <br /> Moisture Removal Pints/h 7.8 <br /> •Sensible Heat Factor 0.72 <br /> Power Factor % 98.0/98.0 <br /> Maximum Capacity BTU/H 34,000 <br /> Rated Capacity BTU/H 32,600 <br /> Minimum Capacity BTU/H 9,800 <br /> Heating at 47°Fz ------------ --Maximum Power Input W 3,580 <br /> Rated Power Input W 3,340 <br /> Power Factor % 98.0/98.0 <br /> Maximum Capacity BTU/H 20,800 <br /> j Heating at 17°F' Rated Capacity BTU/H21.000 <br /> Maximum Power Input W 2.600 <br /> Rated Power Input W 2,500 <br /> Maximum Capacity BTU/H 18.800 <br /> Heating at 5°F: <br /> Maximum Power Input W 2,230 <br /> Heating at-4'F' Maximum Capacity BTU/H 14,200 <br /> SEER 18.1 <br /> E E R' 9.25 <br /> HSPF[IV]�--- _"-- 9.6 <br /> COP at 47°F' 2.86 <br /> Efficiency COP at 17°Fat Maximum Capacity' 2.34 <br /> COP at 5°F at Maximum Capacity' 2.47 <br /> COP at-4°F at Maximum Capacity` 7-4 <br /> ENERGY STAR`Certified No <br /> Voltage,Phase,Frequency 208/230,1,60 <br /> Guaranteed Voltage Range VAC 187-253 <br /> Voltage'.Indoor-Outdoor,S1-S2 VAC 208/230 <br /> Electrical Voltage:Indoor Outdoor,S2-S3 V DC 24 <br /> — -- — — <br /> Short-circuit Current Rating[SCCR] kA 5 <br /> Recommended Fuse/Breaker Size(Oudoor) A 20 <br /> Recommended Wire Size[Indoor-Outdoor] AWG 14 <br /> Power Supply Indoor unit is powered by the outdoor unit <br /> MCA A 1.0 <br /> Fan Motor Full Load Amperage A 0.76 <br /> Fan Motor Output W 56 <br /> Fan Motor Type DC Motor <br /> Airflow Rate at Cooling.Dry CFM 374-602-699-915 <br /> Airflow Rate at Cooling,Wet CFM 374-602-699-915 <br /> Airflow Rate at Heating,Dry CFM 374-602-699-803 <br /> Sound Pressure Level[Cooling] dB[A] 32-42-49-53 <br /> Indoor Unit <br /> Sound Pressure Level[Heating] dB[A] 34-42-49-50 <br /> Drain Pipe Size In.[mm] 5/8[15.88] <br /> Coating on Heat Exchanger Dual Barrier Coating <br /> External Finish Color Munsell 1.OY 9.2/0.2 White <br /> Unit Dimensions W x D x H:In.[mm] 46-1/16 x 11-5/8 x 14-3/8[1170 x 295 x 365] <br /> Package Dimensions W x D x H:In.[mm] 51 x 18-1/2 x 14-1/4[1300 x 470 x 360] <br /> Unit Weight Lbs.[kg] 45[20] <br /> Package Weight Lbs.[kg] 51[22.9] <br /> Indoor Unit Operating Temperature Cooling Intake Air Temp[Maximum/Minimum]' °F 90 DB, 73 WE/67 DB 57 WB <br /> Range Heating Intake Air Temp[Maximum/Minimum] °F 80 DB/70 DB <br /> NOTES: <br /> AHRI Rated Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB <br /> (Rated data is determined at a fixed compressor speed) 'Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WE <br /> 'Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB,15 WE <br /> Conditions 'Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WE//5 DB,4 WB <br /> °Heating at-4°F(Indoor//Outdoor) °F 70 DB,60 WB//-4 DB,-5 WB <br /> "Outdoor Unit Operating Temperature Range(Cooling Air Temp(Maximum/Minimum)): <br /> •Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. <br /> • <br /> "Outdoor Unit Operating Temperature Range(Cooling Thermal Lock-out/Re-start Temperatures;Heating Thermal Lock-out/Re-start Temperatures): <br /> •System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. <br /> Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. <br />