SW 1 /4, SW 1 /4 SECTION 8; NW 1 /4, NW 1 /4 SECTION 1 7; NE 1 /4, NE 1 /4 SECTION 1 8; ALL IN TOWNSHIP 28 N, RANGE 5 E, W.M.
<br /> CITY OF EVERETT, SNOHOMISH COUNTY, WASHINGTON Z
<br /> LEGEND
<br /> • BOL BOLLARD 71 TES TELEPHONE BOX
<br /> ❑ CB A CATCH BASIN TYPE A ( TER TELEPHONE RISER
<br /> CLF CHAINLINK FENCE ❑S TSB TRAFFIC SIGNAL BOX
<br /> CONC CONCRETE TSF TRANSFORMER
<br /> 0 10 20 40 60
<br /> COR CORNER ®TSR TRAFFIC SIGNAL RISER
<br /> scnLe �„=20'
<br /> O CB 2 CATCH BASIN TYPE 2 © TVR CABLE TV RISER
<br /> E❑ EB ELECTRIC BOX UP UTILITY POLE
<br /> NOTE: LEGEND
<br /> Q EL CDT ELECTRIC CONDUIT © VLP POWER VAULT
<br /> EP EDGE OF PAVEMENT ® WM WATER METER
<br /> 1. SEE SHEET C-4 FOR TEMPORARY EROSION AND CB A CATCH BASIN TYPE
<br /> FH FIRE HYDRANT O WSP WATER SPIGOT SEDIMENTATION CONTROL PLAN. CB 2 CATCH BASIN TYPE 2
<br /> FNC FENCE A WTF- GOLDSMITH SURVEY CONTROL POINT 2. SEE SHEET C-5 FOR GRADING,DRAINAGE,AND
<br /> SMH SANITARY SEWER MANHOLE
<br /> D4 WV WATER VALVE FRONTAGE IMPROVEMENTS PLAN. DIRECTION OF FLOW
<br /> FIND FOUND 3. SEE SHEET C-7 FOR WATER AND SANITARY SEWER
<br /> 0 GM GAS METER ® YD YARD DRAIN
<br /> GV GAS VALVE —E 4.UNDERGROUND POWER LINE PLAN. SD— NEW STORM LINE
<br /> PROPOSED WET/DETENTION VAULT SHALL BE —SS— NEW SIDE SEWER LINE
<br /> IBX IRRIGATION BOX —G GAS LINE DESIGNED TO SUPPORT THE WEIGHT OF
<br /> EMERGENCY VEHICLES AND FIRE APPARATUS.
<br /> LP LIGHT POLE —OHU— OVERHEAD POWER LINE W NEW WATER MAIN
<br /> ® ULTRABLOCK WALL
<br /> Q Me MAILBOX SD— STORM LINE FIRE DEPARTMENT CONNECTION(FDQ
<br /> MON MONUMENT —SS— SANITARY SEWER LINE POST INDICATOR VALVE(PIV)
<br /> PLA PLANTER —T TELEPHONE LINE FLOW PATH W!DIRECTION
<br /> O RCF REBAR&CAP FOUND —X FENCE LINE •SDCO STORM DRAIN CLEANOUT
<br /> ED SGN SIGN
<br /> —RD ROOF DRAIN(6 D)
<br /> O SMH SANITARY SEWER MANHOLE -
<br /> --FD---FOOTING DRAIN(6"0)
<br /> X YARD HYDRANT
<br /> --------------------------------------------------------------- =-- -- _._--- - --------------------------- WTF-u�r--------------------
<br /> ' LIMIT OF DISTURBANCE/ " C'::`_::::::::::;':::::]
<br /> LIMIT OF PROPOSED FRONTAGE IMPROVEMENTS / PROJECT AREA
<br /> SEE SHEET C-9 FOR DETAILS / �' B ROADWAY CRC!1,5 WALK-,y t" 1 C8 A
<br /> \ PEOfSIMIAN RAILING-- (- :1 RIM-4sres EXISTING DRIVEWAY
<br /> CONNECT TO EX. T`"d: J E 12'(N)=43306 O BE UTILIZED
<br /> / WATERMAIN n 36
<br /> re A [;: I \ IIE E.6(M)�4s,3.76 PEDESTRIAN RAIL;; -
<br /> ` ' / RIM-44Q05 4;CONCRETE TRASH (.Y?A-... / ._..y_....,.-.....,._.._.,_....`.T_a,....,_..___..W__.._......._._._,A ,._.. _.._,....,._.,v..-_...__._,,r..__.........__,._._uv-......_...,...._yv_..__........_.......,v.._._.,.._._._.,�d.!?(.,- -IE12° ._�: w =1--._._. rro,y._.,.....-, -....._m...,,..... 801__vd,_._._.�.....
<br /> ENCLOSURE AREA RtMx445.03
<br /> IF.8"(N)=44tl.93 /v m PEWS7RIAN RAILENCr '"P k
<br /> CEt A ur IE B"(B) 436 8, "'"
<br /> IF 6'(S)=440.93 RIM--44d 7Y
<br /> rE 12"(NW)=439.76 ...., If.V(S)•-442.2H WV� WV _...____......_t
<br /> .. _..._.....--- _-' -_--'`._______._ .,._.. ............. ............_�-.:_._ .. _-L .,::xw,x.::1-> '==- ___..._;rt2 ..GUARD RAIL ,I .... . ,:,:�roor .�._....._._ ... . L..-_:_____.__—._:...__:._ __.. .__._. _..._.._..----_.__. .,ror .�- -.__. ...,.... - -3'I_Fr ; CV..-..,... Z' v :e �, S(;N 5CN - Sr�, - ISR �- LP
<br /> r. `b7 pp } -�t " i.' f . .._ .._E:_._..._ ..- ...'.fi' /Lf _ P T.ir _.� _ .ICt ,.,_�-.......
<br /> -- _.---- twFDC, - - -
<br /> UY,UC ;.,,�-_.... :,_rn, _._.....__-.... e•... .. ��v,----•-`.ry'... ._sttll'k__.._ ... . ..._ia _...,_...._ ":, r., .. .___.._ ....-._...._..,__ � ... rcN� r .,
<br /> ,,.... .. _.a� .. -_..,.r»u' ._�.. '��-s•. _,._ ...... ,_ ''R"r ---......• �.. ...", �-onu-- _.._....._.Dili. �._.._. -::ri.l-._...:- -.. ........... .,....----..,_, .,. _._.,......�r�nu--._�.._. ..
<br /> r � t, ...,..�_r tifr __.. ..,-a?nfr�. ...............o..rrtf•_�..L'�...,t-4 .......r, �„wG� _ ..__. ,,i ,: .. _orrr,r :__....:�.�...- -r:Hu as.- Irnru
<br /> -
<br /> `�" /.
<br /> i ..... _ .. ". rCl'1'STl1NC -) rrnr - %
<br /> Aji
<br /> UftH P -
<br /> Are ._
<br /> IPROPO
<br /> 434d44.3D,� .BM 1 IF'6/N):d420 ti -'^'` <"'� "' ._ (YRBW Est __......_ _ Ie e('>).a42.r. A 5^'-442 _ - .- �� / PROSERD FIRE
<br /> �.- VIC�EIILINIIES
<br /> l PROPOSED SANITARY �.PrrE'^
<br /> :-
<br /> o � SEWER(TYP.)
<br /> PROPOSED STORM
<br /> .. Ss PAIN7F0. / DRAIN(TYP.)
<br /> (' ,„r \ %.,-.%' •r $Q- "^"' SD- "i GUTLMft
<br /> i SD,' ° .•a', ,r. -'�' ,\' SD J D SD SD
<br /> PI /c
<br /> 0 Y!'
<br /> / _ C
<br /> 11 44i.2.5 /i / �,F70L / t 1 x1 >�� I / '��• Cs
<br /> n
<br /> y
<br /> /
<br /> 4l
<br /> ULTRABLOCK
<br /> _
<br /> / is RETAINING WALL
<br /> _ D SD SD r SD .. b- _8D
<br /> �... _ zrf. � I (TYP.)
<br /> �� //
<br /> \ "' / I I ..",•r r•..c.•'' \1 ,,...•�..`.. v,, ' ,c,.-' lY ..-'"�r _ ....�- Iu1..2FE 2 �\I �....-• -' _..yifi-.. ���..� .// N
<br /> SUMAfUUP VAUL 1 �.� I " :1� ,.._ ._.. ._. _ '.�' \•
<br /> /
<br /> - \ W SO1 r0 LID
<br /> _ ---
<br /> -- -
<br /> ' PROPOSED B DG.
<br /> I
<br /> r
<br /> u
<br /> F ' �I F = 438 5 -- -----
<br /> ,� F IE 12"v/ !14A1 I ---- -...ry�h-..._ I
<br /> r'v vD q , M 12"�E)-125.31 I ( `,-
<br /> /PIMd26s/ a \ )i M
<br /> � �, ti. / °� ~' �' \ ( sYE)=4 7•� ..... \ 1E 12"(w):494.4L
<br /> — � ✓ — WET/DETENTION VAULT
<br /> �" _G0 A sD su"" so 1 g l i " 5 SEE SHEET C-6A FOR DETAILS
<br /> `V
<br /> / �T�'
<br /> \ \ /ATER- ...�......- ' / t)iP�.
<br /> \ $i ..-..��L e,w,+s-- / ......- IC 12
<br /> r
<br /> IL'12(S) 427.,5'1
<br /> �\ u Ir to(. �� ------------------------
<br /> -....,.. ,:,. i l..L,....,--.. ...i r,�a•`" .:'mow, ! ff '.i I
<br /> -- r -- --- -- - --- - '.-lE . ,tr -- - - -- - - - ------------r -----------s 420— fur
<br /> _______ ... _
<br /> ULTRABLOCK \ ~
<br /> t
<br /> RETAINING WALL ^ I Ep/r,REIN
<br /> f` "
<br /> (TYPE)
<br /> PFROVELY
<br /> gal0au"
<br /> All Owes
<br /> CADADLB) `' ^-t• - - _ _ _ - „�._..._- - - _
<br /> _ kW
<br /> PUBLgULTRABL'"OCK CONNECT '
<br /> ^�'b N E DEPARTMENT
<br /> RETAININGce_ RETAINING TO EX.CB
<br /> WALL(TYP.) 15 c N
<br /> APWB 1 WORIfS PERMIT IS REQUIREDPRIOR
<br /> N ON
<br /> Know what's below. ENQIN R
<br /> Call before you dig. \\ \ RO EGTTIAPPROVANG ANY I FOR RTH SUCTIOPR STANDARD
<br /> IS
<br /> `\ \ CONDITIONAL );U NT STANDARDS '
<br /> REV NO. DATE DESCRIPTION MADE BY CHECKED PLOTTED: 2015/08l0410:48 SKIM KEVIN K RENE MULVANEY FOR CONSTRU INA5 I UED
<br /> 3{} (, 2-12-15 PERMIT SUBMITTAL EM LN DRAWN: EMALM ~� °•xs�� SHEET
<br /> 1 3-2-15 BID SET BE SK APPROVED: LNYQUIST a v4 "' �Mc h m f� 7 COMPOSITE SITE PLAN
<br /> 2 6-19-15 REVISED CONSTRUCTION PLANS MB SK FIELD BOOK: 1978/38 C_ n
<br /> 3 7-23-15 REVISED PER CITY'S COMMENTS,DATED 7/8/1 5 MB SK FOR 3
<br /> GOLDSMITH 4 8-4-1 5 REVISED PER CITY'S COMMENTS,DATED 8/3/15 MB SK o�4�sa�eVIVI q0 EV E R ETT STORAGE PROJECT
<br /> �$DL4"`
<br /> LAND DEVELOPMENT SERVICES ° �S �`°NAL
<br /> "` °
<br /> M:\ACAD\PLATS\14\14114\CONSTRUCTIONSE-r\14114PO3.DWG 8407 BROADWAY, CITY OF EVERETT SNOHOMISH COUNTY,WASHINGTON
<br /> 1215114th Ave SE,Bellevue,WA 98004 1 PO Box 3565,Bellevue,WA 98009
<br /> T 425 462 1080 F 425 462 7719 vmm,oldsmithengineerin.com
<br />
|