My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
901 91ST PL SW 2024 Plans 2025-07-16
>
Address Records
>
91ST PL SW
>
901
>
Plans
>
901 91ST PL SW 2024 Plans 2025-07-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/14/2025 1:30:33 PM
Creation date
7/14/2025 1:29:08 PM
Metadata
Fields
Template:
Address Document
Street Name
91ST PL SW
Street Number
901
Permit
B2407-048
Year
2024
Notes
NEW SFR -- MONICH 91ST SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br /> * POST ADDRESS SO AS TO BE LEGIBLE FROM STREET, <br /> NUMBER SHALL CONTRAST FROM BACKGROUND/R319 <br /> * A FLOOR OR LANDING 7W' MAX. BELOW THRESHOLD <br /> IS REO'D ON EA. SIDE OF AN EXIT DOOR/R311.3 <br /> * A 1W' TO 2" CIA. HANDRAIL IS REQ'D 34-38". ABOVE <br /> TREAD NOSING WHEN RISERS TOTAL MORE THAN THREE <br /> AT LEAST ONE HANDRAIL SHALL EXTEND NOT LESS <br /> THAN 12" BEYOND TOP &BOTTOM RISER./R311.7.8 <br /> 12 <br /> TYP. 6 <br /> Eli �D <br /> FRONT ELEVATION SCALE: 1/4"=1'-0" <br /> 2 <br /> ® 12 ® TYP. 5 <br /> TYP. 5 <br /> u� N ur/ <br /> N <br /> VINYL SASH <br /> TYPICAL <br /> HORIZONTAL LAP SIDING <br /> 0/15#FELT 0/3/8" MIN , <br /> SHEAT'G 0/FRAME WALL T <br /> A C <br /> LEFT ELEVATION SCALE: 1 8•=1'-0^ RIGHT ELEVATION SCALE: 1 8"=,'-0" <br /> RIDGE <br /> GRADING AND DRAINAGE ® (STANDARD TRUSSES) HEIGHT CALCULATIONS: <br /> t.FRov OL A SHALL BE MADE FOR THE ELEVATIONS FROM WESI LAND USE CONS. <br /> CONTROL AND DRAINAGE OF SURFACE WATER (NOT ROOF VENT$ NORTH—A = 612.00' <br /> AROUND BUILDINGS BY:GUTTERS,DRAIN LINES, (NOT ALL SHOWN) <br /> INLETS AND CATCH BASINS OR OTHER NECESSARY COMPOSITION ROOFING EAST—B = 612.00' <br /> DRAINAGE STRUCTURES AND SHALL INSTALLED <br /> WHERE STORM UTTER DISPOSAL CANNOT BE METAL GUTTERS TOP PLATE SOUTH—C = 612.00' <br /> OTAINED WITHOUT THEIR USE NI WHERE EROSION WEST 8. = AVE' <br /> CANNOT BE PREVENTED BY FINISH GRADING AND � � TOTAL = 2,448.0/4 = AVERAGE <br /> PLANTING.DRY WELLS SHALL NOT BE INSTALLED \ AVERAGE/BASE ELEVATION = 612.00' <br /> IN AREAS WHERE THE SOIL IS NOT WELL DRAINED <br /> AND/OR POROUS. \ + HEIGHT ALLOWED (28') = 640.00' <br /> 2.GRADING SHALL BE PROVIDED TO ENSURE: ACTUAL BUILDING HEIGHT= 26.96' <br /> (A)DIVERSION OF WATER AWAY FROM BUILDINGS. 12 ELEVATION DESIGN HEIGHT= 638.96' <br /> (B)PREVENTION OF STANDING WATER AND SOIL SATURATION TYP 5 FIN FLOOR <br /> DETRIMENTAL TO STRUCTURES AND LOT USE. <br /> (C)THAT NATURAL DRAINAGE CHANNELS OR BASINS ARE N <br /> (())NOT BLOCKED OR FILLED. <br /> ( PROMSIONS FOR THE DISPOSAL 01 WATER <br /> E)PROTECTION OF ADJOINING PROPERTY. FROM A LOT. <br /> BCD <br /> FIN FLOOR <br /> GRADE <br /> REAR ELEVATION SCALE: 18"=,'-O' <br /> FAWN CREEK DESIGN <br /> 429 PINE CREEK ROAD OF <br /> TONASKET, WA 98855 <br /> 509-486-1988 <br />
The URL can be used to link to this page
Your browser does not support the video tag.