6801 SEAWAY BLVD 2024 Plans 2025-07-16
>
Address Records
>
SEAWAY BLVD
>
6801
>
Plans
>
6801 SEAWAY BLVD 2024 Plans 2025-07-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/14/2025 2:14:17 PM
Creation date
7/14/2025 2:13:53 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
6801
Permit
M2402-105
Year
2024
Notes
NEW COMMERCIAL - INSTALL (6) GAS UINT HEATERS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IF <br /> PIPING GENERAL NOTES DUCTWORK SCHEDULE i E <br /> � U)'. <br /> PIPING MATERIAL SCHEDULE WORKING SMACNA SMACNA < <br /> PIPING SIZE MATERIAL JOINT SERVICE PRESSURE PRESSURE SEAL z is <br /> USAGE LOCATION MATERIAL (IN.WC) CLASS(IN.WC) CLASS NOTES O ° <br /> NATURAL GAS 7l2"-2' $CH 40 BLK STL ERW MEGA-PRESS'G" FLUE EXHAUST FROM FAN TO AMBIENT GALV.STEEL 1 1 B 1 I m E <br /> $ -ALL PIPING INSULATION AND COVERINGS SHALL HAVE AN ASTM FLAME SPREAD RATING OF 25OR LESS AND AN ASTM SMOKE DEVELOPED RATING OF 50 OR LESS. NOTES: O N <br /> wP -ELASTOMERIC INSULATIONS SHALL BE CLOSED CELL. 1.SHEET METAL GAUGES AND FITTINGS PER SMACNA AND MACDONALD-MILLER DUCT CONSTRUCTION STANDARDS. (n <br /> -ELASTOMERIC INSULATIONS WHICH MEET THESE RATINGS MAY BE USED AS A SUBSTITUTE FOR FIBERGLASS. y <br /> -PROVIDE A VAPOR BARRIER COVERING ON ALL CHILLED WATER PIPING AND COIL CONDENSATE PIPING INSULATION. O v <br /> e -PROVIDE A COVERING FOR ALL FIBERGLASS INSULATION WITHIN THE BUILDING. Q J n <br /> -PROVIDE A VINYL JACKET FOR ALL INSULATION EXPOSED TO SIGHT WITHIN THE BUILDING EXCEPT MECHANICAL ROOMS. 5m <br /> -PROVIDE REMOVABLE LACED INSULATION PAD OVER ALL CONTROL VALVES,WHERE NOT LOCATED WITHIN A MECHANICAL ROOM. SEQUENCE OF OPERATIONS cu Q c <br /> B -PROVIDE ALUMINUM JACKET ON ALL INSULATED PIPING OUTSIDE BUILDING. LL c�° <br /> -AT PIPE HANGERS PROVIDE RIGID INSULATION BETWEEN PIPE AND HANGER. n <br /> TYPICAL GAS UNIT HEATER <br /> ,R 1.THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED.THE MECHANICAL CONTRACTOR IS TO COORDINATE WITH ALL SERVES:WAREHOUSE SPACE <br /> y OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. CONTROL TYPE:STAND-ALONE,24/7 OPERATION <br /> SETPOINTS:50"F(ADJ.) <br /> 2.MATERIALS,METHODS,AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2018 INTERNATIONAL BUILDING CODE(IBC),INTERNATIONAL MECHANICAL CODE(IMC), SUMMARY:WHEN HEATING IS NEEDED,THE FAN TURNS ON AND THE UNIT STAGES GAS HEATING TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. .G,M, �. <br /> INTERNATIONAL ENERGY CODE(IEC)AND UNIFORM PLUMBING CODE(UPC)AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. <br /> 3.ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. <br /> 4.SLOPE ALL INDIRECT DRAINS AT 2%UNLESS OTHERWISE NOTED ON DRAWINGS.OBTAIN APPROVAL FROM THE CODE AUTHORITY BEFORE INSTALLING PIPING AT LESS THAN 2% GAS UNIT HEATER SCHEDULE <br /> (EVEN IF LESSER SLOPE IS INDICATED ON DRAWINGS). < 4rggl,�lZo` <br /> UNIT MBH THERM VVr tBBtpMAL tr0 <br /> 5.HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH THE 20181MC AND IBC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES, NO. AREA SERVED MFR.&MODEL NO. CFM I HP INPUT OUTPUT EFF% VOLTIPH AMPS FLUE SIZE LBS NOTES 6/4/2024 <br /> UH-101 WAREHOUSE 101 REZNOR UDX-300 3840 112 *300.0249.0 83 115/1 11.0 6' 277 NEW,1-6 <br /> 6.PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVEDAND FIRE STOPPEDWITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITYAND RATING OF UH-102 WAREHOUSE101 REZNOR UDX-300 3840 112 2.49.0 83 11511 11.0 6' 277 NEW,1-6 <br /> THE FLOOR OR WALL. UH-103 WAREHOUSE101 REZNOR UDX-300 3840 112 249.0 87 11511 11.0 6' 277 NEW,1-6 <br /> UH404 WAREHOUSE101 REZNOR UDX-250 3200 1/4 207.5 83 11511 7.5 5' 223 NEW,1-6 <br /> 7.PROVIDE CHROME PLATE ESCUTCHEON PLATES AT ALL EXPOSED WALL AND CEILING PENETRATIONS. I I I <br /> F <br /> 8.PROVIDE SHUT-OFF VALVES AT ALL EQUIPMENT CONNECTIONS. NOTES: o <br /> 1.PROVIDE THERMOSTAT WTAN SWITCHING.WIRING&T-STAT BY MC,CONDUIT BY EC. <br /> 9.PROVIDE UNION,GROOVED OR FLANGED CONNECTION AT EQUIPMENT FOR FUTURE REMOVAL AND SERVICING. 2.FOR USE W/NATURAL GAS. <br /> 3.W/1.5 PSI INLET PRESSURE REGULATOR. <br /> 10.FOR CONDENSATE PIPING PROVIDE TRAPS WITH A MINIMUM SEAL 2'GREATER THAN THE FAN OPERATING STATIC PRESSURE AT ALL COOLING COIL CONNECTIONS. 4.W/ALUMINIZED STEEL HEAT EXCHANGER. <br /> 5.W/4 POINT SUSPENSION KIT. <br /> 11.PROVIDE MINIMUM V AIR BREAK FOR ALL CONDENSATE PIPE TERMINATIONS AT DRAINS. 6.WAREHOUSE SPACE IS CLASSIFIED AS SEMI-HEATED CONDITION.PROVIDED WITH 5.19 BTUH/SOFT OF HEATING,LESS THAN CODE 2018 WSEC CODE C402.1.1.2 MAX OF 8.0 BTUHISQFI. <br /> 12.PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. <br /> 6i <br /> GAS PRESSURE REDUCING VALVE SCHEDULE o <br /> PIPING SYSTEM ABBREVIATIONS LOCATION& GAS BODY BODY ORIFICE VALVE INLET OUTLET SPRING w <br /> UNIT NO. SERVICE MFR.&MODEL NO. SCFH TYPE SIZE SIZE ANGLE PRESS PRESS COLOR NOTES I <br /> ABBV FULL NAME ABBV FULL NAME _ ABBV FULL NAME GR-R1-1 ROOF MAXITROL 325-SL 300 GLOBE 3A" 1.5 PSI T WC BLUE 1,73 <br /> C CONDENSATE INDIRECT DRAIN GLWR GLYCOL WATER RETURN NGV NATURAL GAS VENT GR-Rl-2 ROOF MAXITROL 3253L 300 GLOBE 314" - - 1.5 PSI 7"WC BLUE 1,2,3 <br /> CA AIR COMPRESSED GLWS GLYCOL WATER SUPPLY PA AIR PNEUMATIC I N N N NI N U,CDWR CONDENSER WATER RETURN HHWR HEATING HOT WATER RETURN PC CONDENSATE PUMPED GR-R2-1 ROOF MAXITROL 3253L 300 GLOBE 3/4.. - - 1.5 PSI 7"WC BLUE 1,2,3 0 4 'A Q <br /> CDWS CONDENSER WATER SUPPLY HHWS HEATING HOT WATER SUPPLY PCHR CHILLED WATER(PROCESS)RETURN GR-R2-2 ROOF MAXITROL 32, 250 GLOBE 314" 1.5 PSI 7'WC BLUE 1,2,3 0 <br /> CHRV CHILLER RELIEF VENT HPC STEAM CONDENSATE HIGH PRESS PCHS CHILLED WATER(PROCESS)SUPPLY GR-R3-1 ROOF MAXITROL 325-5L 300 GLOBE 314" 1.5 PSI 7'WC BLUE 1,2,3 c o 0 0 0 <br /> CH CHILLED WATER RETURN HIPS STEAM HIGH PRESS RGAS REFRIGERANT HOT GAS GRA3-2 ROOF MAXITROL 325-5L 300 GLOBE 3/4' 1.5 PSI 7'WC BLUE 1,2,3 <br /> CHWS CHILLED WATER SUPPLY HRR HEAT RECOVERY RETURN RLIQ REFRIGERANT LIQUID w <br /> CLN STM STEAM CLEAN HRS HEAT RECOVERY SUPPLY RSUC REFRIGERANT SUCTION y <br /> SCHR CHILLED WATER(SECONDARY)RETUN <br /> CLS CLOSED LOOP WATER SUPPLY LPG LIQUID PROPANE CONDENSATE LOW PRESS SCHS CHILLED WATER(SECONDARY)SUPPLY NOTES: N N Zp <br /> COMB-PVC AIR COMBUSTION PVC LPS STEAM LOW PRESS SCV STEAM CONDENSATE VENT CRYV CRYO VENT LTCR CHILLED WATER(LOW TEMP)RETURN SEC STEAM CONDENSATE PUMPED 1.GAS PRESSURE REGULATOR SIZING BASED ON 2 PSI NATURAL GAS AT METER WITH A PRESSURE DROP TO 1.5 PSI AT PRESSURE REGULATOR AT FULL FLOW.AN OVER PRESSURIZATION Z z LD <br /> DTWS DUAL TEMP WATER SUPPLY LTCS CHILLED WATER(LOW TEMP)SUPPLY SV STEAM VENT DEVICE IS NOT REQUIRED. z 0 O U y 0 <br /> DTWR DUAL TEMP WATER RETURN MPC STEAM CONDENSATE MEDIUM PRESS VAC VACUUM 2.GAS REGULATOR LOCATED ON ROOF,NO VENT LIMITER REQUIRED. <br /> FOC FUEL OIL SECONDARY CONTAINMENT MPS STEAM MEDIUM PRESS VAC-E VACUUM EXHAUST 3.GAS REGULATOR TO BE CERTIFIED FOR 60 PSI EMERGENCY INLET PRESSURE EXPOSURE. 0 w <br /> FOF FUEL OIL FILL MUW MAKE-UP WATER VRFG VRF HOT GAS <br /> FOR FUEL OIL RETURN NG-CONDUIT NATURAL GAS CONDUIT VRFL VRF HIGH PRESS LIQUID w z <br /> FOS FUEL OIL SUPPLY NG-H NATURAL GAS HIGH PRESS VRFS VRF LOW PRESS SUCTION <br /> FOV FUEL OIL VENTS NG-L NATURAL GAS LOW PRESS a 0U a LU a w <br /> GENX GENERATOR EXHAUST NG-M NATURAL GAS MEDIUM PRESS laaaaa <br /> PIPING SYMBOL LEGEND <br /> SYMBOL DESCRIPTION ABBV SYMBOL DESCRIPTION ABBV N <br /> VALVE TWO-WAY CONTROL 2WAY Q SENSOR SNSR LL <br /> VALVE THREE-WAY CONTROL 3WAY 4 TEMPERATURE INDICATOR THERM Uj <br /> VALVE AUTOMATIC FLOW CONTROL AF Tu METER BTU BTU MTR <br /> 0 VALVE BALANCING BALV SUB-METER WATER FLOW MTR z <br /> 0 VALVE BALANCING AUTOMATIC ABALV PRESSURE/TEMPERATURE PORT PAT LU z <br /> XI VALVE BALL-FULL PORTED BV © SENSOR PRESSURE DIFFERENTIAL DP V O <br /> D41 VALVE BALL-W/3/4'HOSE ADAPTOR BV W/HA Hy STRAINER STRN <br /> 0, VALVE BUTTERFLY BEV SUCTION DIFFUSER SUC DIFF U <br /> lsj VALVE BUTTERFLY-W/MEMORY STOP BFVM - UNION UNION UN �D <br /> N VALVE CHECK CV HOSE BIBB HB Of LL <br /> Till VALVE CIRCUIT SETTER CS 'L PIPE BREAK-PIGTAIL w <br /> IT4 VALVE GAS COCK GC $ POINT OF CONNECTION P.O.C. z <br /> D4 VALVE GATE GV D CONCENTRIC REDUCER CR O <br /> VALVE GLOBE GLV ECCENTRIC REDUCER ER O U) U <br /> VALVE PRESSURE REDUCING PRV 6'CHWS PIPE-SIZE ABBREVIATION U O o W Of <br /> VALVE PRESSURE RELIEF RV s_cxws ___ PIPE-SIZE&ABBREVIATION WITH INSULATION ]N J <br /> 0 <br /> VALVE SOLENOID SV THERMAL EXPANSION DEVICE EXP m Z) LL <br /> Q AUTOMATIC AIR VENT AV YU FLEXIBLE CONNECTION � Q¢ � Q <br /> MANUAL AIR VENT MAV 4 FLEX PIPE Q W> LLJ <br /> WATER HAMMER ARRESTOR WHA PIPE-HEAT TRACE a LU Lu T <br /> �' U U) <br /> I� BACKFLOW PREVENTER BFP ® PUMP �L.L.� o W `^ '^ <br /> ® REDUCED PRESS.BACKFLOW PREVENTER RPBP AIR SEPARATOR AIR SEP U) §0 W V)� vJ <br /> TT BULB WELL BW CHEMICAL POT FEEDER CPOT ENGINEER_ <br /> FLOW DIRECTION ARROW HEATEXCHANGER HTX <br /> G TOWNSEND 06-03-24 <br /> Q PRESSURE INDICATOR PRESS EXPANSION TANK ET CHE-D BY. <br /> DATE PLOTTED <br /> G GRAHAM 06-03-24 <br /> CAD ISSUE DATE <br /> F MAMERTO 06-03-24 <br /> RABIING NUMBER <br /> DC-2730-72236221-00 <br /> SHEET NUMBER <br /> City of Everett Permit Review M O.02 <br /> EVERETT Status:Approved <br /> 06/06/2024 1:17:41 PM <br />