Laserfiche WebLink
DevCo, Inc. ES-6516 <br /> April 1, 2019 Page 10 <br /> Infiltration Feasibility <br /> As indicated in the Subsurface section of this report, native soils encountered during our fieldwork <br /> were characterized primarily as dense to very dense glacial till deposits. Based upon the results <br /> of USDA textural analyses performed on representative soil samples, native soils are also <br /> classified as gravelly sandy loam, gravelly course sandy loam, and very gravelly loam. Fines <br /> contents were about 30 to 47 percent within the sandy loam and about 50 percent within the <br /> gravelly loam, at the tested locations. Given the appreciable fines contents and dense to very <br /> dense in-situ condition of the till, it is our opinion full-scale infiltration is not feasible from a <br /> geotechnical standpoint. Small scale infiltration devices incorporating overflow may be feasible <br /> and can be further evaluated by ESNW, if requested. <br /> Preliminary Detention Vault Design <br /> Although unspecified at this time, we presume a detention vault will be used as the primary means <br /> of stormwater management. Based on our experience with similar projects, we assume grade <br /> cuts of 10 or more feet will be necessary to achieve the subgrade elevation of the vault foundation. <br /> Based on our field observations, grade cuts for the vault are likely to expose dense to very dense, <br /> undisturbed glacial till. <br /> The vault foundation should be supported directly on competent native soils. Should <br /> overexcavation(s) be necessary at the vault foundation subgrade, quarry spalls should be used <br /> to restore grades. The final vault design must incorporate adequate buffer space from property <br /> boundaries such that temporary excavations to construct the vault structure may be successfully <br /> completed. Perimeter drains should be installed around the vault and conveyed to an approved <br /> discharge point. Perched groundwater seepage should be anticipated within the vault <br /> excavation; however, buoyancy is not expected to influence the vault structure. <br /> The following preliminary design parameters may be used for the vault: <br /> • Allowable soil bearing capacity 5,000 psf (dense native soil) <br /> • Active earth pressure (unrestrained) 35 pcf <br /> • Active earth pressure (unrestrained, hydrostatic) 80 pcf <br /> • At-rest earth pressure (restrained) 50 pcf <br /> • At-rest earth pressure (restrained, hydrostatic) 95 pcf <br /> • Coefficient of friction 0.40 <br /> • Passive earth pressure 350 pcf <br /> • Seismic surcharge 6H psf* <br /> Where H equals the retained height(in feet) <br /> Earth Solutions NW,LLC <br />