Heartland Construction, LLC ES-6516.09 <br /> March 24, 2021 Page 2 <br /> BMP T5-10C (Perforated Stub-Out) — Section 3.1.3 of Vol. 3 of the drainage manual states the <br /> following: <br /> "Perforated stub-outs are not appropriate when seasonal water table is less than one foot below <br /> trench bottom." <br /> Based on the dense to very dense (low permeability) glacial till deposits identified throughout the <br /> site, the seasonal (perched) water table is expected to develop at relatively shallow depths. In <br /> this respect, high certainty exists that a seasonal water table would develop within one foot of a <br /> perforated stub-out trench bottom. On this basis, perforated stub-out applications are not <br /> considered feasible for the project. <br /> We trust this letter and geotechnical assessment meet your current needs. If you have any <br /> questions, or if additional information is required, please call. <br /> Sincerely, <br /> EARTH SOLUTIONS NW, LLC <br /> A. CO <br /> E WASH C� <br /> un <br /> 1 <br /> � � 8 <br /> /STER�� G\�� <br /> SfONAL 03/24/2021 <br /> Chase G. Halsen, L.G. Raymond A. Coglas, P.E. <br /> Project Geologist Principal Engineer <br /> cc: CPH Consultants, Inc. <br /> Attention: Mr. Colton Darden, P.E. (Email only) <br /> Earth Solutions NW, LLC <br />