Laserfiche WebLink
WATER SYMBOLS SIGNALIZATION SYMBOLS CHANNELIZATION SYMBOLS ABBREVIATIONS LINETYPES <br /> SYMBOL SYMBOL SYMBOL ADJ ADJUST LINETYPE DESCRIPTION <br /> EXIST. PROP. DESCRIPTION EXIST. PROP. DESCRIPTION EXIST. PROP. DESCRIPTION ALIGN ALIGNMENT SURFACE FEATURES: <br /> ALT ALTERNATE ��������������� <br /> • EXISTING BUILDING LINE <br /> CAP/PLUG � � AERIAL DISCONNECT � BIKE PATH AP ANGLE POINT <br /> o T <br /> COUPLING APPROX APPROXIMATELY PROPOSED BUILDING LINE <br /> f AERIAL TERMINAL COMPARTMENT ASPH ASPHALT <br /> GUARD POST ck HANDICAP SYMBOL AVE AVENUE EXISTING DITCH <br /> DIPOLE DETECTOR <br /> AVG AVERAGE - PROPOSED DITCH <br /> E. D ► REDUCER 0 ' H.O.V. LANE SYMBOL BM BENCH MARK EXISTING CURB/PAVEMENT/SIDEWALK <br /> a THRUST BLOCKING NOT BOTTOM PROPOSED CURB/PAVEMENT/SIDEWALK <br /> 63 im WATER METER QUADRAPOLE DETECTOR ���1 OIIYI ONLY BTWN BETWEEN . <br /> 1■ILI —x— EXISTING FENCE LINE <br /> o CB CATCH BASIN <br /> J R }L FIRE HYDRANT 2-NOZZLE O ROUND LOOP DETECTOR CB1 CATCH BASIN TYPE 1 —xxxxxx— PROPOSED FENCE LINE <br /> -6 FIRE HYDRANT 3-NOZZLE CB2 CATCH BASIN TYPE 2 EXISTING GRAVEL <br /> CG CURB & GUTTER <br /> z KE <br /> RAILROAD CROSSING C/L, CL, CENTERLINEEXISTING GUARDRAIL <br /> II II FLANGE/BLIND FL (FL) (BL FL) PEDESTRIAN DETECTOR R R <br /> [ [ MECHANICAL JOINT MJ COM COMMON PROPOSED GUARDRAIL <br /> ( ) CONC CONCRETE <br /> 0 3o- INDICATOR LIGHT CONN CONNECTION _ _ <br /> C C PUSH-ON/HUBS - MA ��IIOOI WETLAND/SWAMP PERIMETER <br /> o ilk SCHOOL CONST CONSTRUCT <br /> THREAD OPTICOM SENSOR CONT CONTINUED/CONTINUOUS RAILROAD <br /> i AIR RELIEF VALVE DET DETAIL EXISTING RETAINING WALL <br /> q T BLOW-OFF VALVE ING <br /> INDICATORPTICOM SENSOR LIGHTS W/ ��0� SLOP STOP DWG EAST,, VERTICAL DISTANCE PROPOSED RETAINING WALL <br /> IL BUTTERFLY VALVE BETWEEN PVI AND ROAD SURFACE <br /> 4 RIVERBANK/SHORELINE <br /> EA EACH <br /> m RI N CHECK VALVE ��"- `�` FLASHING WARING SYSTEM STRAIGHT ARROW EL ELEVATION VEGETATION LINE <br /> m N GATE/GENERAL VALVE EX, EXIST EXISTING <br /> ® z m m 0 0 JUNCTION BOXES (TYPE I, II, III) SURVEY: <br /> PH FIRE HYDRANT <br /> a K8 M' PLUG VALVE ll�`IIIrNJ� LT.RT.STR. ARROW FT FEET/FOOT EXISTING CENTERLINE <br /> N 61 4& PEDESTRIAN PUSHBUTTON G GAS LINE - - PROPOSED CENTERLINE <br /> POST W/ PUSHBUTTON GE GROUND ELEVATION <br /> GAS POWER/TELEPHONE SYMBOLS — — PEDESTRIAN SIGNAL HEAD LEFT-RIGHT ARROW GV GAS VALVE *** EXISTING CONTOUR (INTERMEDIATE) <br /> HORIZ HORIZONTAL EXISTING CONTOUR (INDEX) <br /> SYMBOL O l HIPS HIGH PRESSURE SODIUM *** PROPOSED CONTOUR (INTERMEDIATE) <br /> SIGNAL POLE NOTE y <br /> HT HEIGHT *** PROPOSED CONTOUR (INDEX) <br /> EXIST. PROP. DESCRIPTION ` 2-WAY LEFT TURN E NVERT ELEVATION <br /> O 0 GAS METER � IN INCH/INCHES R/R CROSSING GATE — — EXISTING EASEMENT LINE <br /> INT INTERSECTION ------- PROPOSED EASEMENT LINE <br /> o Cp A1, GAS VALVES R/R CROSSING SIGNAL <br /> LEFT TURN ARROW K RATE OF VERTICAL CURVATURE EXISTING PROPERTY LINE <br /> PAD MOUNTED TRANSFORMER (LENGTH (FT) PER % DILL. IN GRADE)A FA ® m SIGNAL CONTROLLER L LENGTH OF ARC - - EXISTING RIGHT OF WAY CENTERLINE <br /> o © © POWER VAULT RIGHT TURN ARROW <br /> LB POUND EXISTING RIGHT OF WAY <br /> ® ® SIGNAL LOAD CENTER LBS POUNDS ——————————— EXISTING RIGHT OF WAY (USED) <br /> o LF LINEAL FOOT/FEET <br /> TRANSMISSION TOWER A PROPOSED RIGHT OF WAY <br /> STREET LIGHT ASSEMBLY LT LEFT <br /> 0 o t UTILITY POLE ^ LEFT-STRAIGHT ARROW LUMIN LUMINAIRE SECTION LINE <br /> E-- c--- UTILITY POLE ANCHOR o� TRAFFIC SIGN-BRIDGE MAX MAXIMUM QUARTER SECTION LINE <br /> IL <br /> o • TELEPHONE RISER MIT MANHOLE 16TH SECTION LINE <br /> 4 FT OT RIGHT-STRAIGHT ARROW TELEPHONE VAULT TRAFFIC SIGN-CANTILEVERED MIN MINIMUM UTILITIES (EXISTING) <br /> MON MONUMENT <br /> TRAFFIC SIGN-SINGLE POST o • LANE MARKER TYPE I N NORTH G EXISTING GAS LINE <br /> SURVEY SYMBOLS NA NOT APPLICABLE OP EXISTING AERIAL POWER <br /> ,2 NTS NOT TO SCALE BP EXISTING BURIED POWER <br /> TRAFFIC SIGN-DOUBLE POST LI ■ LANE MARKER TYPE II OPP OPPOSITE <br /> SYMBOL PC POINT OF CURVE SD EXISTING STORM DRAIN <br /> EXIST. PROP. DESCRIPTION r o TRAFFIC SIGNAL POLE PT POINT OF TANGENT FM EXISTING FORCE MAIN <br /> PVC POLYVINYL CHLORIDE / SS EXISTING SANITARY SEWER <br /> ANGLE POINT TRAFFIC SIGNAL POLE CURVE <br /> SURFACE FEATURES/LANDSCAPING PVI POINT OF VERTNT OF ICAL INTERSECTION W/ LUMINAIRE <br /> BENCH MARK <br /> OT EXISTING AERIAL TELEPHONE <br /> SYMBOL PVMT PAVEMENT BT EXISTING BURIED TELEPHONE <br /> i 0 • BLOCK CORNER O TRAFFIC SIGNAL PVT POINT OF VERTICAL TANGENT W EXISTING WATER LINE <br /> SUPPORT POLE EXIST. PROP. DESCRIPTION R RADIUS <br /> o • IRON PIPE BEE REFERENCE UTILITIES (PROPOSED) <br /> 2 ® • MONUMENT IN CASE VEHICLE SIGNAL HEAD RR RAILROAD <br /> ( ) BUS BUS BUS STOP RT RIGHT G PROPOSED GAS LINE <br /> ® MONUMENT (SURFACE) VEHICLE SIGNAL HEAD R/W, ROW RIGHT OF WAY OR PROPOSED AERIAL POWER <br /> l� OWNERSHIP TIE W/ ARROW INDICATOR EMBANKMENT S SOUTH BP PROPOSED BURIED POWER <br /> lo O o - SD STORM DRAIN SO PROPOSED STORM DRAIN <br /> SECTION CENTER WIRE NOTE MAIL BOX STILT STREET LIGHT <br /> SLJB STREET LIGHTING JUNCTION BOX FM PROPOSED FORCE MAIN <br /> RIP RAP SS SANITARY SEWER SS PROPOSED SANITARY SEWER <br /> o <br /> SECTION CORNER SANITARYZSTORM SEWER SYMBOLS ST STREET <br /> CCGC1 C1G't ROCKERY STA STATION OT PROPOSED AERIAL TELEPHONE <br /> i S/W SIDEWALK BT PROPOSED BURIED TELEPHONE <br /> x QUARTER CORNER SYMBOL SHRUB TOO TOP OF CURB W PROPOSED WATER LINE <br /> TV TELEVISION <br /> SIGN CUSTOM: <br /> O SIXTEENTH CORNER EXIST. PROP. DESCRIPTION i UT UTILITY <br /> • SANITARY SEWER CLEAN OUT <br /> CLOSING CORNER VERT VERTICAL CUT CUT LINE <br /> O SANITARY SEWER MANHOLE- TREE (CONIFER) W WEST, WATER LINE <br /> FILL FILL LINE <br /> C_MC 0-0 MC <br /> MEANDER CORNER p ® STORM DRAIN CATCH BASIN TYPE 1 W/ WITH DATUM <br /> ( ) TREE (DECIDUOUS) SILT FENCE <br /> o. oWC •yyC WITNESS CORNER STORM DRAIN CULVERT CONSTRUCTION FENCE <br /> ® ® SOIL BORING/POTHOLING O STORM DRAIN CATCH BASIN (TYPE 2) O • FENCE POST <br /> nl x ® SPOT ELEVATION STORM DRAIN MANHOLE CURB RAMP <br /> O ■ ■ ENERGY DISSIPATOR NORTH ARROW <br /> TAX LOT/PARCEL NUMBER X YARD LIGHT DATUM <br /> ® ® OVERFLOW STRUCTURE 15. <br /> W NSHELTER HOLDINGS, LLC °r°W' N° <br /> PERTEETHOUGHTALING 8t;8 19 GN2 <br /> Designed By EVERETT RIVERFRONT DEVELOPMENT <br /> 2707 COLBY AVENUE,SUITE 900 84968 `� chew d By 8 u 1s sneer No. <br /> EVERET,,WA 98201 Know what's below. �`�,rse°ISTE `` ADVANCED SITE WORK PERMIT 2 <br /> No. Dote Res;o B A 425.252.77001800.615.9900 oNA� ECG Approved By p2018 N inner LEGEND AND ABBREVIATIONS 28 <br /> G y ppr. Call before you dig C. DONNER 8 18 19 20180004.005 of Total <br />