GENERAL NOTES LEGAL DESCRIPTION PROJECT DATA FREIHEIT <br /> CONSTRUCTION PLUMBING,MECHANICAL&ELECTRICAL Section 07 Township 28 Range 05 Quarter SW-TH PTN OF SW 1/4 DAF-COM AT W IA CDR SD SEC TH N87*41 PROJECT ADDRESS: 7802 EVERGREEN WAY ARCHITECTURE <br /> 47E AEG E-W C/L SD SEC 20FT TO E RM LN OF BEVERLY LN TH S01*41 33E ALG SD E-W RAN LN 604.15FT EVERETT,WA 98203 <br /> 1.ALL CONSTRUCTION SHALL COMPLY WITH THE 2018 INTERNATIONAL BUILDING CODE AS ADOPTED BY 1.PLUMBING,MECHANICAL,&ELECTRICAL DRAWINGS ARE TO BE SUBMITTED UNDER SEPARATE THN88*42 29E PLW S LN SO SW 1/4 794.54FT WE TAP 450FT NWLY OF WH MEAS AT R/A TO MON CIL OF <br /> THE CITYOF EVERETT,STATE REGULATIONS FOR BARRIER FREE DESIGN,WA STATE ENERGY CODE, PERMIT. EVERGREEN WAY&POB TH CONT N88*42 29E 470.93FT M/L TO NWLY RIW LN EVERGREEN WAY TH S30*33 <br /> AND ALL APPLICABLE LOCAL CODES,ORDINANCES,AND STANDARDS.IN CASE OF ANY CONFLICT WHERE 47W ALG SD NWLYRAN LN 312Ff TH N85*25 08W 444.97FT TAP ON SD LN PLW&45OFT NWLY OF JURISDICTION: SNOHOMISH COUNTY <br /> THE METHODS OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR 2.MECHANICAL&ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE TO MAINTAIN COMPLIANCE EVERGREEN WAY CIL BEAR S30*33 47W 258.39FT FR POB TH N30*33 47E 258.39FT TO POB&TGW TH PTN <br /> EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES,THE LAWS OR ORDINANCES SHALL WITH APPLICABLE CODES AND STANDARDS AND OBTAIN ALL NECESSARY PERMITS AND APPROVALS. THOF DAF-TH PTN SW1/4 DAF-COM ATW 1/4 CDR SO SEC TH N87*41 47E ALG E-W C/L SO SEC 20FT TO E PARCEL NUMBER: 28050700300700 <br /> GOVERN.NOTIFY THE ARCHITECT OF ALL CONFLICTS. RIW OF BEVERLY LN TH S01*41 33E ALG SD E RAN LN 604.15FI TH N88*42 29E 794.44FT TAP 45OFT NWLY <br /> 3.MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE BIDDER DESIGN/BUILD.THE CONTRACTOR SHALL OF WH MEAS AT R/A TO MON C/L OF EVERGREEN WAY&TPB TH N30*33 47E PLT SO MON C/L 93.17FT TH ZONING: B <br /> 2.SECURE RELEVANT CITY AND STATE APPROVALS RELATING TO FIRE,CONSTRUCTION,LABOR,HEALTH BE RESPONSIBLE FOR OBTAINING THE CORRESPONDING PERMITS FOR WORK.THE PROPOSED N88*42 29E 470.93FT TO NWLY RNJ OF EVERGREEN WAY TH S30*33 47W ALG SD RAN 93.17FT TH S88*42 <br /> AND LICENSING.CONTRACTOR SHALL FURTHER POST ALL BONDS AND SECURE ALL INSURANCE SYSTEM DESIGN&METHOD OF OPERATION FOR ALL ROOMS SHALL BE REVIEWED AND APPROVED BY 29W 470.93FT TO TPB(PER CITY EVE BLA REC AF NO 200109070551&200109075003) OCCUPANCY CLASSIFICATION: BUSINESS <br /> REQUIRED BY LAW OR CONTRACT,FORWARDING PROOF OF SUCH ACTIONS TO THE LANDLORD PRIOR THE TENANT PRIOR TO THE START OF ANY WORK. <br /> TO COMMENCEMENT OF CONSTRUCTION. TYPE OF CONSTRUCTION: III-B <br /> 4.WHERE APPLICABLE,STRUCTURAL,PLUMBING,MECHANICAL,ELECTRICAL,AND FIRE PROTECTION DESCRIPTION OF WORK <br /> 3.WORK NOT INCLUDED IN THIS CONTRACT SHALL BE MARKED"N.I.C."OR SPECIFICALLY ASSIGNED TO DRAWINGS ARE SUPPLEMENTARY TO THESE DRAWINGS.THE CONTRACTOR SHALL NOTIFY THE SPRINKLERED: YES <br /> ANOTHER PARTY. ARCHITECT OF ALL DISCREPANCIES BETWEEN THE CONSULTANTS'DRAWINGS WITH A WRITTEN <br /> REQUEST FOR CLARIFICATION.ANY WORK INSTALLED IN CONFLICT WITH THESE DRAWINGS OR REMODEL OF EXISTING SHOWROOM TO CURRENT HYUNDAI BRANDING STANDARDS.DEMOLITION OF THE NUMBER OF STORIES: 2 <br /> 4.CONTRACTOR SHALL VISIT THE SITE,REVIEW THE DRAWINGS AS SUBMITTED BY THE ARCHITECT,AND SPECIFICATIONS SHALL BE CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO THE BUILDING EXISTING SHOWROOM AND FRONT BUILDING FACADE TO ACCOMMODATE NEW SHOWROOM.ADDITION OF <br /> BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO BIDDING OR CONSTRUCTION. OWNER,TENANT,OR ARCHITECT. EXISTING INTERIOR OFFICES TO ACCOMMODATE NEW SALES FLOOR,LOUNGE,SERVICE COUNTER,AND SQ.FT.OF EXISTING PARTS AND SERIVCE <br /> NEW CAR DELIVERY AREA.ADJUSTMENT OF THE SERVICE BUILDINGS TO ACCOMMODATE NEW PARTS AND SERVICE BUILDING: 7,480 <br /> 5.ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURERS LATEST 5.ALL CABLING AND WIRING NOT IN CONDUITS OR FULL SURROUND CABLE TRAYS SHALL HAVE A RESTROOMS.NEW FINISHES THROUGHOUT. REWORK OF SITE TO ACCOMMODATE NEW SHOWROOM SOUTH SERVICE ANNEX BUILDING: 9,741 <br /> RECOMMENDATIONS OR WRITTEN DIRECTIONS. FLAME SPREAD RATING OF LESS THAN 25 AND A SMOKE DEVELOPMENT RANGE OF LESS THAN 50. AND LANDSCAPE MODIFICATIONS. <br /> 6.WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK,THE 6.ALL EXPOSED MATERIAL&PIPING IN RETURN AIR PLENUM MUST MEET FS 25. SO.FT.OF EXISTING SHOWROOM <br /> DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. SEPERATE PERMITS FIRST FLOOR: 5,368 <br /> 7.ALL PLUMBING AND HVAC PIPE AND DUCTWORK IN PLENUM SHALL HAVE A FLAME SPREAD RATING SECOND FLOOR: 2,288 J <br /> 7.WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR,IT IS INTENDED OF LESS THAN 25 AND A SMOKE DEVELOPMENT RANGE OF LESS THAN 50 EXISTING TOTAL: 7�56 <br /> THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES,ITEMS OR PARTS AS ARE REQUIRED TO LLB <br /> PROPERLY COMPLETE THE WORK. SQ.FT.OF SHOWROOM IMPROVEMENT Q <br /> SUBMITTALS AND WARRANTY THE FOLLOWING PORTIONS OF THE PROJECT WILL BE APPLIED FOR UNDER SEPARATE PERMITS: FIRST FLOOR: 9,848 <br /> 8.VERIFY ALL"BUILDING STANDARDS"WITH BUILDING OWNER PRIOR TO BEGINNING ANY WORK. FIRST FLOOR EXPANSION: 4,480 O <br /> HOWEVER,THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS 1.SUBMIT A LIST OF PROPOSED PRODUCT SUBMITTALS AND SHOP DRAWINGS TO THE OWNER FOR 1.HVAC SYSTEM.(DUCTING,DISTRIBUTION,CONTROLS,AND ASSOCIATED STRUCTURAL) C <br /> WITHOUT THE ARCHITECTS WRITTEN APPROVAL THEREOF.THE CONTRACTOR AGREES TO DEFEND, APPROVAL PRIOR TO START OF CONSTRUCTION. 2.LINE VOLTAGE ELECTRICAL SYSTEM WORK. ROSECOND FLOOR: iZ,288 Z <br /> INDEMNIFY,AND HOLD THE ARCHITECT HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF 3.LIFE SAFETY SYSTEMS.(HORNS,STROBES&FIRE ALARM/SPRINKLER IMPROVEMENTS) 1 1 I <br /> UNAPPROVED CHANGES. 2.ALL PRODUCTS AND MATERIALS SPECIFIED IN THE DRAWINGS(WITH EXCEPTION TO SPECIFIC FINISH 4,LOW VOLTAGE ELECTRICAL SYSTEMS.(TELEPHONE/DATA/SECURITY/INTERCOM) 2 �W�// <br /> COLORS AND FLOORING)ARE INTENDED TO BE ON AN"OR EQUAL"BASIS.ANY PROPOSED 5.PLUMBING(WATER,SANITARY,NATURAL GAS) PROJECT VALUATION BREAKDOWN LL <br /> 9.LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM SUBSTITUTIONS MUST BE SUBMITTED TO THE ARCHITECT IN WRITING FOR APPROVAL WITHOUT DELAY 6.SIGN PACKAGE <br /> DAMAGE.THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OF SCHEDULE. <br /> OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THIS WORK. Building only improvements related to existing space(TI)_$1.155.712.00 W <br /> 3.ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE(1)YEAR AFTER COMPLETION,UNLESS APPLICABLE CODES <br /> 10.VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS OTHERWISE OTHERWISE SPECIFIED,AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN PROPOSAL AND New building/addition(increase in footprint)_$739,200(Business>Type III-B 4.480SF X 165$/SF) '_^ <br /> NOTED IN THE PLANS OR SPECIFICATIONS. AGREEMENT.ALL REPAIRS,CORRECTIONS,DISCREPANCIES,ETC.,MUST BE MADE WITHOUT ANY V J <br /> ADDITIONAL COST TO THE OWNER,AND WITHIN FIVE(5)DAYS AFTER NOTICE IS GIVEN. <br /> 11.ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN Q <br /> (BROOM)CONDITION AT ALL TIMES. NATIONAL: <br /> FIRE PROTECTION 20181NTERNATIONAL BUILDING CODE W/WASHINGTON STATE AMENDMENTS(51-50 WAC) z <br /> 12.PROTECT ADJACENT WORK AND REPAIR ANY DAMAGE AT CONTRACTOR'S OWN EXPENSE. 20181NTERNATIONAL EXISTING BUILDING CODE <br /> 1. FIRE PROTECTION DRAWINGS ARE TO BE SUBMITTED UNDER SEPARATE PERMIT. 2018 INTERNATIONAL FIRE CODE W/WASHINGTON STATE AMENDMENTS(51-54 WAC) Q <br /> 13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE 2018 INTERNATIONAL MECHANICAL CODE W/WASHINGTON STATE AMENDMENTS(51-52 WAC) <br /> WITH ALL APPLICABLE SAFETY CODES. 2.IF NECESSARY,PROVIDE FIRE PROTECTION AT ALL PENETRATIONS OF FIRE RELATED ELEMENTS AS 20091CC At 17.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 73 <br /> REQUIRED BY CODE. ZONING DATA O <br /> 14.THE CONTRACTOR SHALL INDEMNIFY AND HOLD THE BUILDING OWNER/ARCHITECT/ENGINEER REGIONAL: <br /> HARMLESS FOR INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BY THE 3.FIRE EXTINGUISHERS:VERIFY LOCATION,TYPE,AND SIZE PER FIRE MARSHAL REQUIREMENTS. 2018 WASHINGTON STATE ENERGY CODE(51-11 WAC) <br /> NEGLIGENCE OF THE CONTRACTOR,HIS AGENTS,EMPLOYEES,OR SUBCONTRACTORS. CONTRACTOR TO PROVIDE ALL TEMPORARY AND PERMANENT FIRE EXTINGUISHERS REQUIRED UNDER 2018 WASHINGTON STATE ADMINSTRATIVE CODE(WAC) 0�/ <br /> N.F.P.A.10 MOST RECENT EDITION AND APPROVED BY THE FIRE MARSHAL.CONFIRM ACCEPTABILITY OF PER EMC BZONING REQUIREMENTS LL >_- <br /> 15.APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKERS.ALL LOCATION WITH FIRE MARSHAL PRIOR TO INSTALLATION.PROVIDE FINISHED CABINETS TO MATCH 2O18 EVERETT MUNICIPAL CODE Q <br /> CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS WELL AS ALL REVISIONS,ADDENDA, BUILDING STANDARD FOR EXTINGUISHERS AT ALL EXPOSED LOCATIONS. REQUIRED(EMC) PROPOSED M <br /> AND CHANGE ORDERS.THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION,ONE COMPLETE LANDSCAPE SETBACKS: O <br /> SET OF PLANS WITH ALL REVISIONS,ADDENDA,AND CHANGE ORDERS,ON THE PREMISES AT ALL TIMES 4.FIRE EXTINGUISHERS AND CABINETS SHOULD BE LOCATED SO THAT THE TOP OF THE EXTINGUISHER VICINITY MAP STREE FRONTAGE:2'FRONTAGE,6'SIDEWALK,4'LANDSCAPE ZONE SEE SHEET A2.01 O z N <br /> WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. OR CABINET IS NO HIGHER THAN 48"AFF AND THE TOP OF THE EXTINGUISHER OR CABINET HANDLE IS SIDES:5'TYPE III LANDSCAPE BUFFER SEE SHEET A2.01 T LU) Q 00 <br /> 16.MAINTAIN ALL EXIT PATHWAYS DURING CONSTRUCTION. <br /> AT LEAST 36"AFF. REAR:10'TYPE I LANDSCAPE BUFFER SEE SHEET A2.01 1 <br /> 5.AT SEMI-RECESSED FIRE EXTINGUISHER CABINETS WRAP ADDITIONAL LAYER(S)OF TYPE'X'GYPSUM U <br /> 17.PROVIDE COMPLETE SECURITY OF THE TENANT SUITE WHILE JOB IS IN PROGRESS AND UNTIL THE WALL BOARD INTO THE CABINET CAVITY TO MAINTAIN SPECIFIED FIRE RATED REQUIREMENT.REFER TO PER EMC 19.35.080: <br /> JOB IS COMPLETED. WALL CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. 4.OUTDOOR STORAGE AREAS AND VEHICLE SALES DO NOT REQUIRE INTERIOR LANDSCAPING <br /> 18.AT COMPLETION OF THE WORK,REMOVE ALL DEBRIS FROM THE SITE,LEAVING SPACE CLEAN,WASH 6.PROVIDE AND INSTALL FIRE EXTINGUISHER SIGNAGE(5"X6")ABOVE EACH FIRE EXTINGUISHER OR 0 LLI <br /> ALL WINDOWS AND GLASS,POLISH ALL HARDWARE AND FIXTURES.REPLACE AND PATCH AREAS OF CABINET WITHIN THE SCOPE OF THE TENANT IMPROVEMENT.MOUNT AT 84"AFF UNLESS OTHERWISE STRUCTURE HEIGHT ALLOWED EMC PROPOSED > <br /> CEILING DAMAGED DUE TO LIGHTING INSTALLATION OR MECHANICAL ADJUSTMENT. REQUIRED. _+ EMC 19.22.020 50' NO CHANGE TO EXISTING MAXIMUM HEIGHT Z LLJ <br /> 19.MINIMIZE DISRUPTIONS OF BUILDING OCCUPANTS DUE TO NOISE,ODOR,FUMES,OR VIBRATION.AT 7.EXIT SIGNS AND EXIT ILLUMINATION SHALL CONFORM TO THE 2018 IBC AND THE CITY OF EVERETT Fx \r� w <br /> THE END OF CONSTRUCTION THE CONTRACTOR SHALL COMPLETELY CLEAN ALL AREAS SOILED BY FIREMARSHAL REQUIREMENTS.CONTRACTOR TO PROVIDE AND INSTALL EMERGENCY LIGHTING AND LANDSCAPE MODIFCIATION T (D w <br /> CONSTRUCTION ACTIVITIES INCLUDING THOSE IN WHICH NO WORK WAS DONE. EXIT LIGHTING AS REQUIRED BY THE EVERETT FIRE AND BUILDING DEPARTMENTS.CONFIRM 1 <br /> ACCEPTABILITY OF LOCATIONS WITH THE BUILDING OWNER BEFORE INSTALLATION.CONTRACTOR <br /> 20.LATHING,PLASTER,AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO CHAPTER 25 OF THE SHALL PROVIDE AND INSTALL AUDIBLE ALARMS IN ACCORDANCE WITH IBC ARTICLE 9.CONTRACTOR REQUIRED LANDSACPING <br /> 2018 LB.C. SHALL PROVIDE AND INSTALL VISIBLE ALARM SIGNALS AS REQUIRED BY ADA GUIDELINES. WEST PROPERTY LINE: 3,520 SF(10 FT TYPE I BUFFFER) <br /> CONTRACTOR SHALL PROVIDE AND INSTALL ALL SMOKE DETECTORS AND SMOKE DETECTION AS SOUTH PROPERTY LINE: 2,220 SF(51FT TYPE III BUFFER) <br /> 21.ALL GLASS AND GLAZING SHALL COMPLY WITH CHAPTER 24 OF THE 2018 LB.C.AND THE U.S. REQUIRED UNDER ARTICLE 9 OF THE IBC.THE INSTALLATION OF THE ABOVE NOTED SYSTEM SHALL NORTH PROPERTY LINE: 2,220 SF(5FT TYPE III BUFFER) <br /> PRODUCT SAFETY COMMISSION:SAFETY STANDARDS FOR ARCHITECTURAL GLAZING MATERIALS(42 FIR INCLUDE THE CONNECTION TO AND/OR MODIFICATION OF THE EXISTING BUILDING SYSTEMS,AS STREET FRONTAGE: 1,408 SF(4FT LANDSCAPE/FURNITURE ZONE) <br /> 1426:16 CFR PART 1201). NECESSARY. INTERNAL: N/A(CAR SALES AND SERVICE USE <br /> 22.VERIFY ALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND WINDOW 8.EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL REQUIRED LANDSCAPING: 9.368 SF <br /> MANUFACTURERS. KNOWLEDGE OR EFFORT. <br /> PROVIDED LANDSACPING <br /> 23.DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONSTRUCTION DRAWING SHOULD BE 9.FLAMMABLE LIQUIDS SHALL NOT BE PLACED,STORED,OR DISPENSED IN THIS OCCUPANCY EXCEPT WEST,SOUTH, <br /> CALLED TO THE ATTENTION OF THE ARCHITECT. AS PROVIDED IN NFPA STANDARD 30 AND THE 2018 INTERNATIONAL FIRE CODE.PERMIT MAY BE NORTH PROPERTY <br /> REQUIRED. LINES COMBINED: 7,686 SF(VARIABLE WITH TYPE I&III BUFFFER) <br /> 24.CONSTRUCT WALLS PLUMB AND SQUARE WITH EXISTING STRUCTURE AND NEW CONSTRUCTION STREET FRONTAGE: 3,249 SF(EXISTING AREAS TO BE UPGRADED) <br /> UNLESS NOTED OTHERWISE. 10.ALL DRAPES,HANGINGS,CURTAINS,AND ALL OTHER DECORATIVE MATERIAL,INCLUDING INTERNAL: 1,152 SF(TYPE III) <br /> CHRISTMAS TREES THAT WOULD TEND TO INCREASE THE FIRE AND PANIC HAZARD SHALL BE MADE <br /> 25.COORDINATION:THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION AND FROM NONFLAMMABLE MATERIAL,OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT _- PROVIDED LANDSCAPING: 12.087 SF <br /> COORDINATION OF THE WORK OF ALL TRADES TO ASSURE COMPLIANCE WITH THE DRAWINGS. CONDITION BY MEANS OF A FLAME RETARDANT SOLUTION OR PROCESS APPROVED BY THE FIRE <br /> MARSHAL.PROVIDE A CERTIFICATION TO THIS EFFECT.EXIT DOORS,EXIT LIGHTS,AND FIRE PARKING CALCULATIONS <br /> 26.ANY DEVIATIONS FROM DIMENSIONED LOCATIONS MUST BE APPROVED BY THE ARCHITECT. EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE _ 1273a <br /> MATERIAL.MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISHES SHALL BE PER TABLE 1-; REGISTERED <br /> 803.9,SECTION 803.1 OF THE 20181BCs PER EMC 12.16.030:RETAIL TRADE AND SERVICES,OUTDOOR INCLUDING 1:1000 SF <br /> DIMENSION :+ 4' ARCHITECT <br /> 11.ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE V ,, .r?I* 1 . (1/1000)29.357=30 STALLS <br /> 1.ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE SPECIFIC RATING. TOTAL PUBLIC PARKING REQUIRED=30 STALLS <br /> BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY.THE CONTRACTOR SHALL <br /> VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY PROJECT LOCATION TOTAL PARKING PROVIDED: <br /> DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE CEILING <br /> WORK. REGULAR 28 MICHAEL J. L TON <br /> 1.REFLECTED CEILING PLAN IS FOR THE GENERAL INFORMATION OF THE CONTRACTOR.EXACT ACCESSIBLE 2 STATE OF WASHINGTON <br /> 2.DIMENSIONS OF PLANS ARE TYPICAL TO THE CENTERLINE OF COLUMNS AND FINISHED GWB FACE OF LOCATIONS SHOULD BE VERIFIED. TOTAL 30 PUBLIC STALLS TOTAL <br /> PARTITIONS,UNLESS NOTED OTHERWISE.DOOR AND CASED OPENINGS WITHOUT LOCATION - <br /> DIMENSIONS ARE TO BE FOUR(4)INCHES FROM THE FACE OF THE ADJACENT PARTITION OR CENTERED <br /> BETWEEN PARTITIONS.3.DO NOT SCALE DRAWINGS.THE CONTRACTOR SHALL USE DIMENSIONS DOOR REQUIRED PARKING STALLS <br /> SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS.NOTIFY THE ARCHITECT IF PER 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN TABLE 208.2:THE TOTAL NUMBER OF PARKING ISSUE LIST <br /> DISCREPANCIES ARE FOUND. 1.ALL DOOR HARDWARE TO MEET REQUIREMENTS OF 2018 IBC AND OWNER'S BUILDING SPACES PROVIDED IS 30;THUS FOR 25-50 STALLS PROVIDED,2 ACCESSIBLE STALLS ARE REQUIRED. <br /> REQUIREMENTS. I PERMIT SUBMITTAL 0.31.2022 <br /> REQUIRED BICYCLE PARKING PER BMC 12.16.030: ONE BICYCLE PARKING FOR EVERY 12 REQUIRED MOTOR PRICING UPDATE 08.09.2022 <br /> CONSTRUCTION 2.COORDINATE ALL KEYING REQUIREMENTS WITH OWNER/TENANT.CONTRACTOR SHALL PROVIDE ALL - - VEHICLE SPACES,UP TO A MAXIMUM REQUIREMENT OF 20 BICYCLE SPACES.30/12=3 BICYCLE PARKING 1 BLDG REVISION 09.30.2022 <br /> LOCKSET CYLINDERS TO MATCH OWNER STANDARD.CONTRACTOR SHALL RE-KEY ALL DOORS TO MEET REQUIRED. <br /> 1.INVESTIGATE AND VERIFY LOCATIONS OF EXISTING STRUCTURAL,PLUMBING,MECHANICAL,AND TENANT AND OWNER'S REQUIREMENTS. 2 PW REVISION 3 PLANNING/PW REVISION 1 11..23.2022 <br /> .2022 <br /> ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF ANY AND ALL <br /> DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. <br /> FINISH AND MATERIALS D I� <br /> 2.COORDINATE CONSTRUCTION SCHEDULING WITH THE BUILDING OWNER TO ALLOW ONGOING <br /> OPERATION OF THE FACILITY DURING CONSTRUCTION. 1.SUBMIT FINISH SAMPLES TO TENANT AND OWNER FOR APPROVAL PRIOR TO ORDERING MATERIALS. g` <br /> 3.PROVIDE BLOCKING AS REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. 2.INTERSECTION OF SCHEDULED FLOORING MATERIALS ARE TO OCCUR AT CENTERLINE OF DOOR <br /> WHEN IN A FULLY CLOSED POSITION UNLESS NOTED OTHERWISE. ART$AND SERVICE BUILDING <br /> 4.OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. <br /> 3.PROVIDE APPROPRIATE TRANSITION MATERIAL AS REQUIRED WHERE DISSIMILAR FLOORING <br /> 5.PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. MATERIALS INTERSECT. <br /> 6.PATCH AND REPAIR ALL EXISTING SURFACES AS REQUIRED BY DEMOLITION AND NEW CONSTRUCTION <br /> TO RECEIVE NEW SCHEDULED FINISHES.ALL SURFACES ARE TO HAVE"LIKE-NEW"APPEARANCE. WH <br /> SOUTH SERVICE ANEX BUILDING <br /> 7.STUD HEIGHT AND SPACING LIMITATION OF STEEL FRAMING COMPONENTS SHOULD BE IN <br /> COMPLIANCE WITH ASTM C 754 FOR MAXIMUM DEFLECTION AND MINIMUM LATERAL LOADING <br /> REQUIREMENTS. <br /> 8.ALL DEMOLISHED MATERIALS TO BE RECYCLED TO AN APPROVED RECYCLER. R <br /> GENERAL NOTES <br /> SITE PLAN BUILDING DIAGRAM � A0.01 <br />