FINISH GRADE IRRIGATION SCHEDULE
<br /> IRRIGATION NOTES:
<br /> SYMBOL MANUFACTURER/MODEL/DESCRIPTION P� SYMBOL MANUFACTURER/MODEL/DESCRIPTION 1. PROVIDE & INSTALL ALL IRRIGATION IN
<br /> I CONFORMANCE WITH THE CITY OF EVERETT
<br /> HUNTER PROS-06—PRS30—CV 10' RADIUS HUNTER ICV—G STANDARDS & DETAILS. IN THE EVENT OF CONFLICT
<br /> —III— BETWEEN SPECIFICATIONS, NOTES, OR DETAILS &
<br /> —_ — ROUND BOX iD m m m TURF SPRAY, 30 PSI REGULATED 6" POP—UP. 30 1', 1-1/2", 2", AND 3" PLASTIC THE
<br /> W/LOCKING Q T H F WITH FACTORY INSTALLED DRAIN CHECK VALVE. ELECTRIC REMOTE CONTROL VALVES, CITY OF EVERETT STANDARDS & DETAILS, Arehiu,mr i c.
<br /> I F I I F COVER CO—MOLDED WIPER SEAL WITH UV RESISTANT GLOBE CONFIGURATION, WITH NPT STANDARDS & DETAILS SHALL TAKE PRECEDENCE. www an".ra.Fom
<br /> MATERIAL. THREADED INLET/OUTLET, FOR
<br /> BRASS GATE VALVE. SIZE COMMERCIAL/MUNICIPAL USE. 2. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE
<br /> �� _ HUNTER PROS—O6—PRS30—CV ADJUSTABLE ARC CODES AND APPROPRIATE SAFETY REGULATIONS.
<br /> 18" MIN. —I I I— —III SHALL MAINLINEBES SIZE.
<br /> TO o®0 ®®� TURF SPRAY, 30 PSI REGULATED 6" POP—UP. 30 MATCO—NORCA 514T
<br /> I IWITH FACTORY INSTALLED DRAIN CHECK VALVE. 1/2"-4" BRASS GATE VALVE, FULL PORT, 3. IRRIGATION DRAWINGS ARE SCHEMATIC. ACTUAL
<br /> CO—MOLDED WIPER SEAL WITH UV RESISTANT WITH SOLID WEDGE. IPS. CROWN HANDLE. LOCATIONS MAY VARY DUE TO UTILITIES ES NSIBLE
<br /> LEE JOHNSON
<br /> EXISTING CONDITIONS. CONTRACTOR
<br /> MATERIAL. SAME SIZE AS MAINLINE PIPE. FOR LOCAT LOCATING UTILITIES PRIOR TO BEGINNING H YUN DAI
<br /> SCH 80 NIPPLE (1 OF HUNTER MP CORNER PROS-06—PRS40—CV HUNTER ICV—G 1-1/2" CONSTRUCTION. DEALERSHIP
<br /> 2, TYP,) SHRUB ROTATOR, POP—UP WITH FACTORY 1", 1-1/2", 2", AND 3" PLASTIC
<br /> SCH 80 PVC UNION (1 OO INSTALLED CHECK VALVE, PRESSURE REGULATED 40 ELECTRIC MASTER VALVE, GLOBE
<br /> TO 40 PSI, MP ROTATOR NOZZLE. � 4. ALL IRRIGATION EQUIPMENT SHALL BE LOCATED
<br /> OF 2, TYP.) CONFIGURATION, WITH NPT THREADED WITHIN PROJECT PROPERTY LINES & WITHIN
<br /> T=TURQUOISE ADJ ARC 45-105 ON PRS40 LANDSCAPE BEDS WITH THE EXCEPTION OF ITEMS IN
<br /> BODY.BRICK (1 OF 2, TYP.) Y. INLET/OUTLET, FOR THE RIGHT OF WAY. ITEMS SHOWN OFF PROPERTY
<br /> PVC MAINLINE I FI •—•+III HUNTER MP STRIP PROS-06—PRS40—CV COMMERCIAL/MUNICIPAL USE. OR IN HARDSCAPE ARE FOR CLARITY ONLY.
<br /> SIZE ON PLAN — — — COMPACTED
<br /> SUBGRADE SHRUB ROTATOR, 6" POP—UP WITH FACTORY eF ZURN 950XLT 1-1/2"CONCRETE THRUST (DOG INSTALLED CHECK VALVE, PRESSURE REGULATED 40 DOUBLE CHECK VALVE ASSEMBLY 5. PRESSURE IS 78 PSI. PRIOR TO
<br /> INSTALLATION EXISTING PRESOF S IRRIGATION SYSTEM, CONTRACTOR
<br /> BLOCK `STSSTRST TO 40 PSI, MP ROTATOR NOZZLE. LST=IVORY
<br /> LEFT STRIP, SST=BROWN SIDE STRIP, HUNTER IC-1200—M SHALL FIELD VERIFY EXISTING P.S.I. NOTIFY
<br /> GATE VALVE RST=COPPER RIGHT STRIP ON PRS40 BODY. © MODULAR CONTROLLER, 12 STATIONS, OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES
<br /> 1 OUTDOOR MODEL, METAL CABINET. BETWEEN THE DESIGN P.S.I. PRIOR TO PROCEEDING
<br /> HUNTER MPSOOSR PROS-06—PRS40—CV COMMERCIAL USE. WITH ONE ICM-600 W/ WORK.
<br /> SHRUB ROTATOR, 6" POP—UP WITH CHECK MODULE INCLUDED. 7800 EVERGREEN WAY
<br /> PAVING sA lTF VALVE, PRESSURE REGULATED TO 40 PSI, MP 40 HUNTER ROAMXL—KIT 6. SYSTEM DESIGNED TO 40 P.S.I. AT ROTARY SPRAY EVERETT, WA 98203
<br /> ROTATOR NOZZLE ON PRS40 BODY. TRANSMITTER AND RECEIVER. ROAM HEADS & 30 P.S.I. AT SPRAY HEADS. SEE
<br /> ADJ=ORANGE AND GRAY ( ARC 90-210), REMOTE ALLOWS FOR CONTROLLER IRRIGATION SCHEDULE FOR HEAD DESIGN
<br /> 360=LIME GREEN AND GRAY (ARC 360) OPERATION UP TO 2 MILES. PRESSURES. Design Tenn,
<br /> CONTRACTOR, LARGE—SCALE SITES.
<br /> HUNTER MP815 PROS-06—PRS40—CV 7. LOCATE QUICK COUPLING VALVE & AUTOMATIC
<br /> WORKS WITH HUNTER ACC, I—CORE, Design
<br /> SHRUB ROTATOR, 6" POP—UP WITH CHECK CONTROL VALVES AT POINT OF EASY ACCESS.
<br /> PRO—C, PCC, AND X—CORE MZ/aA
<br /> VALVE, PRESSURE REGULATED TO 40 PSI, MP OWNER'S REPRESENTATIVE TO REVIEW & APPROVE
<br /> I I III III— ®O® 40 CONTROLLERS. SMARTPORT WIRING Dr
<br /> ROTATOR NOZZLE. M=MAROON AND GRAY ADJ HARNESS INCLUDED. FINAL LOCATION OF ALL QUICK COUPLERS & JA
<br /> ARC 90 TO 210, L=LIGHT BLUE AND GRAY 210 AUTOMATIC CONTROL VALVES PRIOR TO C„ee„ed
<br /> TO 270 ARC, O=OLIVE AND GRAY 360 ARC ON HUNTER SOLAR—SYNC INSTALLATION. _ MZ
<br /> SOLAR, FREEZE SENSOR
<br /> DETECT—A—TAPE (RED) PRS40 BODY. OU DOORAIN INTERFACE, CON EC SI TO 8. HEAD LOCATION MUST BE ADJUSTED IN THE FIELD 03/30/2022
<br /> z = — 6" BELOW GRADE ® HUNTER PCC, PRO—C, AND I—CORE TO COMPLY W/ EXISTING SITE CONDITIONS AND N.
<br /> CONTROLLERS, INSTALL AS NOTED. PLANT MATERIALS. ADJUST SPRAY PATTERN FOR
<br /> v
<br /> w CLEAN, COMPACTED, INCLUDES 10 YEAR LITHIUM BATTERY AND MAXIMUM COVERAGE. Approed/Date
<br /> > — RUBBER MODULE COVER, AND GUTTER
<br /> 0 SUITABLE, NATIVE MOUNT BRACKET. WIRED.
<br /> BACKFILL 9. ALL IRRIGATION SLEEVING TO BE STAKED IN THE
<br /> HUNTER HFS—FCT-100 FIELD & LOCATED ON DIMENSIONED "AS—BUILT" Revisions
<br /> FS FLOW SENSOR FOR USE WITH ACC DRAWING TO ALLOW FUTURE LOCATION & USE.
<br /> — PVC CONDUIT (SIZE AS D01e D111,
<br /> SPECIFIED IN NOTES). CONTROLLER, 1" SCHEDULE 40 SENSOR 11. ALL IRRIGATION SLEEVES SHALL BE TWICE THE i� 21 22 PERMIT REVISIONS
<br /> BODY, 24 VAC, 2 AMP.
<br /> 7+ POINT OF CONNECTION 1 1/2" DIAMETER OF THE INSERT PIPE(S). SLEEVES SHALL
<br /> PVC (GRAY) ELECTRICAL NOT EXCEED 6" DIAMETER.
<br /> CONDUIT SIZE AS NEEDED IRRIGATION LATERAL LINE: PVC SCHEDULE
<br /> NOTE: O TO ACCOMODATE WIRES. 40 12 BPVC END AIINOFEMA CATI NPSPE.ARE SCHEMATIC. NO
<br /> WHEN PLACING
<br /> PIPING ON DECKING, — IRRIGATION MAINLINE: PVC SCHEDULE 40
<br /> 13. NO VALVE MANIFOLDS. GROUP VALVES TOGETHER
<br /> PLACE PIPING IN A —III W/ TEES 3' APART.
<br /> SLEEVE & DIRECTLY —______— PIPE SLEEVE: PVC SCHEDULE 40
<br /> ON DECKING BELOW
<br /> PAVERS. 14. WHEN GROUPED TOGETHER, VALVE BOXES SHALL BE
<br /> LEVEL & OPEN SAME DIRECTION.
<br /> 6" WIDE TRENCH meRpToe, Key Plan
<br /> (OR AS REQUIRED TO ALLOW ADEQUATE # # "° 15. AIR BLOW IRRIGATION SYSTEM THROUGH QUICK
<br /> COMPACTION OF BACKFILL) #" COUPLERS TO WINTERIZE IRRIGATION SYSTEM.
<br /> TRENCHING UNDER PAVING 16. PIPES TO SHARE TRENCHES WHERE POSSIBLE.
<br /> 2 SEPARATE COMMON PIPING BY 6" MIN.
<br /> PIP COCKS SHALL BE UPRIGHT 17. WHERE PIPE SIZES ARE NOT SHOWN ON THE PLAN,
<br /> FOGTITE #2 METER BOX & EASILY ACCESSIBLE (TYP.) PIPE SHALL BE SIZED TO THE NEXT LARGEST PIPE
<br /> (CONCRETE WITH METAL LID TYP.) FEBCO 850U SERIES DCVA/BACKFLOW SIZE SHOWN UPSTREAM ON THE PLAN.
<br /> FINISH GRADE ASSEMBLY (TYP.) 18. LETTERS ON PIPING SHALL BE ROTATED TO FACE Registration
<br /> UP.
<br /> WAS
<br /> _j 19. GENERAL CONTRACTOR TO PROVIDE AND INSTALL OoVNt.zor�tic
<br /> ALL CONDUIT TO CONTROLLER LOCATIONS & POINTS
<br /> ca OF CONNECTION.
<br /> N ALL BRASS 20. GENERAL CONTRACTOR TO PROVIDE POWER SOURCE
<br /> FITTINGS,
<br /> IPPLES & ?T- OWNER SIGON REIPRES REPRESENTATIVE PRIORCONTROLLER. ETO BEGINNING W/
<br /> IFY LOCATION
<br /> N y°s0' ex P.objO�
<br /> UNIONS TYP
<br /> WORK) Pe AR
<br /> N
<br /> (BUILD UP WITH BOX
<br /> Z EXTENSION OR BRICKS 21. INSTALL FLOW SENSOR PER MANUFACTURER'S
<br /> o (MUELLER) MANUAL (AS REQUIRED TYP.) WRITTEN INSTRUCTIONS. shoot Title
<br /> BRASS PIPE FROM I DRAIN VALVE BRASS PIPE TO 22. INSTALL SOLAR SYNC SENSOR PER IRRIGATION
<br /> POC TO DCVA ASSEMBLY MASTER VALVE MANUFACTURER'S WRITTEN INSTRUCTIONS.j=l SCHEDULE,
<br /> —BRASS DETAILS &
<br /> NOTCH OUT SECTION OF J v v PLUG v U U((11
<br /> BOX AROUND PIPES (TYP.) —�UO�OO"U 6 �JO�OO�oOOwOO
<br /> NOTES
<br /> 3" OF 1-1/2" WASHED sheet No
<br /> ROCK OVER GEOFABRIC
<br /> 3 DOUBLE CHECK VALVE ASSEMBLY
<br /> 2M
<br />
|