Laserfiche WebLink
GENERAL NOTES-CODE PLAN FREIHEIT <br /> STAIR WIDTH QBC 1005...00 <br /> 13 OCC CC LOAD FACTOR OCC � 1.MODIFICATIONS TO FIRE ALARM AND SPRINKLER SYSTEMS UNDER SEPARATE PERMIT <br /> (E)IT 1 (0.3"OVID=3.9'REQUIRED 1 \Y ARCHITECTURE <br /> STORAGE ROVIDED 3.9'EQ (E)OFFICE 2.DOORS IN PATH OF EGRESS CANNOT BE LOCKED FROM SIDE OF TRAVEL OF <br /> TRAVEL DISTANCE=121'95' B 161 SF (N)TECH -� EMERGENCY EGRESS <br /> J 150 20 I BREAK ROOM 3.PROVIDE ONE(1)FIRE EXTINGUISHER(MINIMUM 2A10-B)EVERY 3000 SF(TYP)WITH <br /> 4 270 SF MAXIMUM 75 LINEAR FEET TRAVEL DISTANCE TO EXTINGUISHER;VERIFY LOCATIONS ARE <br /> 15 18 ACCEPTABLE WITH FIRE MARSHAL <br /> /* (E)HALL (E)STORAGE _ <br /> 3}� L�������� B 54 SF L�� 4.PROVIDE AND INSTALL SIGNAGE ABOVE THE MAIN ENTRY DOOR ON THE EGRESS SIDE <br /> TYP 150 1 ICOMMON PATH=27'4" STATING:'THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". <br /> CN-05 5.PROVIDE NEW SPRINKLERS AS REQUIRED TO ACCOMODATE TO NEW CONSTRUCTION. <br /> LL ® RELOCATE EXISTING AS REQUIRED.(UNDER SEPARATE PERMIT). <br /> (E)STORAGE C 2 _Ty,_———————— —� 1 <br /> (E)OFFICE (E)OFFICE TYP 130CC <br /> B 199 SF B 138 SF <br /> 150 2O 150 1O w STAIR WIDTH QBC 1005.3) <br /> (E)RR (E)OFFICE (E)OFFICE CC LOAD FACTOR OCC <br /> B 147 SF B 130 SF �.(0.3")x(13)=3.9"REQUIRED <br /> 15Q � t5o � s PROVIDED 4"CLEAR KEYNOTES-CODE PLAN <br /> J CN-01 NEW ILLUMINATED EMERGENCY EXIT SIGN. <br /> ~ CN-02 EXISTING ILLUMINATED EMERGENCY EXIT SIGN. J <br /> CN-03 VERIFY ALL LOCATIONS OF FIRE ALARMS,DETECTION DEVICES,AND HORNS/STROBES <br /> ACCEPTABLE WITH FIRE MARSHAL.REWORK AS REQUIRED TO ACCOMODATE TO NEW w <br /> CONSTRUCTION. Q <br /> CN-04 PROVIDE AND INSTALL NEW FIRE EXTINGUSHER(MINIMUM 2A10-BC).VERIFY LOCATIONS <br /> ACCEPTABLE WITH FIRE MARSHAL. O <br /> CN-05 EXISTING FIRE EXTINGUSHER TO REMAIN. C <br /> SHOWROOM BELOW W <br /> CODE SUMMARY Lli <br /> OCCUPANCY: B(BUSINESS) '^ <br /> SPRINKLERED: YES v <br /> COMMON PATH OF EGRESS(IBC TABLE 1006.2.1): 100'MAX Z <br /> EXIT ACCESS TRAVEL DISTANCE(IBC TABLE 1017.2): 300'MAX <br /> DEAD END CORRIDOR(IBC 1020.4): 50'MAX <br /> NUMBER OF EXITS(IBC 1006): 3 REQUIRED C <br /> O <br /> OCCUPANT LOAD FACTOR(IBC TABLE 1004.1.2): PER PLAN n/ } <br /> TOTAL AREA: PER PLAN LL <br /> 61LW NUMBER OF OCCUPANTS: PER PLAN �l > O <br /> PLUMBING SUMMARY O Z N <br /> � <br /> SHOWROOM 2ND FLOOR CODE PLAN a s 16 I Lu W <br /> SHOWROOM 2� 2 B(BUSINESS) Q <br /> A1.00 OCCUPANCY: 108OCCUPANTS >> <br /> NUMBER OF OCCUPANTS: 54 <br /> MALE OCCUPANTS: 54 <br /> FEMALE OCCUPANTS: 0 W <br /> REQUIRED: PROVIDED: 7 > W <br /> 3 3 L <br /> II II WATER CLOSETS-MALE(PER IBC TABLE 2902.1): 3 3 W � <br /> DOOR WIDTH(IBC 1005.3) IF WATER CLOSETS-FEMALE(PER IBC TABLE 2902.11: N <br /> OCC LOAD FACTOR x OCC 41111112 7 OCC -- - cl <br /> W <br /> (02)x(27)=5.4'REQUIRED 2 3 T 00 W <br /> PROVIDED=36'CLEAR L , E LAVATORIES-MALE(PER IBC TABLE 2902.V: 2 3 1 <br /> TRAVEL DISTANCE=12Y-7" O OFFICE E STAIR //� "4 LAVATORIES-FEMALE(PER IBC TABLE 2902.1): <br /> B 59 SF (E)ELEC (E) W (E)BREAK DOOR WIDTH(IBC 1005.3) <br /> B 80 SF CONFERENCE ROOM �OCC LOAD FACTOR x OCC N/A 1 <br /> r, 150 iO B 116 SF _A^<403 SF (0.2')x(54)=FACTOR <br /> DRINKING FOUNTAINS(PER IBC TABLE 2902.1): N/A 1 <br /> (N)SERVICE I\ (T--fir, I CN-03 <br /> MANAGER 150 O 115010 15 27 PROVIDED=36"CLEAR SERVICE SINK(PER IBC TABLE 2902.11: <br /> B 131 SF \ LL_)L J TYP 136OCC <br /> 150 1 \\ F 7I ® _I_ (E)HA 54 OCC <br /> RS <br /> r�r_7 <br /> AI (N) ` LEGEND-CODE PLAN <br /> 1- \ 71 CUSTOMER ra <br /> _ \ I LOUNGE <br /> \ L�I LI B 847 SF LONGEST COMMON PATH OF <br /> �1[ / —HALL NO WORK THIS AREA .� <br /> TII 150 © - E)MIENS RR- �E WOMEN EGRESS TRAVEL <br /> R TRAVELDISTANCE=1W-7" <br /> �-n� II L J 1 CC o EXISTING CONSTRUCTION LONGEST EXIT ACCESS <br /> L J — <br /> TO REMAIN TRAVEL DISTANCE <br /> N (N)SALES '�(N)SALESp (N)SALES <br /> ( )SERVICE ----- OFFICE MANAGERS— NEW WALL CONSTRUCTION 9 DEAD END CORRIDOR <br /> r�r� <br /> WRITERS \ I (N)OFFICE OFFIC <br /> \ B 103 SF B 83 SF B 185SF 1 <br /> B 378 SF !Fj� 150 1 B 92 S 12733 <br /> 0 150 1O 150 1O 156 E STAI NEW PARTIAL HEIGHTWALL REGISTERED <br /> 150 30 I\`PF ® i DIAGONAL DISTANCE <br /> CONSTRUCTION ARCHITECT <br /> dI J <br /> -17 y�-�+ r I \2 O O ® (� FIRE EXTINGUISHER ------- EXIT SEPARATION <br /> 1 (N)SERIVCE <br /> c _DRI 15 SF I Ill ® \� ® INTERNALLY ILLUMINATED * OCCUPANCY COUNT AT EXIT MICHAEL <br /> l SHOWROOM p/� y y (N)F&I OFFICE EXIT SIGN J. L TON <br /> 200 ® ((_ _)y �� �� �� (') �OO/y�0/87 B3�F -� 118SF OOCC STATE OF WASHINGTON <br /> AN � 150 1 NEW CAR ® INTERNALLY ILLUMINATED EXIT ROOM NAME <br /> V Cp;1gy, 150 26 lK6 0 DELIEVERY <br /> UY/ / SIGN WITH HORN/STROBE ROOM NA OCCUPANCY <br /> � A- 0 SF�SQUARE FOOTAGE <br /> ♦ `_ `� �� ��� �_ / / _ 15 7 OCCUPANT COUNT ISSUE LIST <br /> --- AA AA LOAD FACTOR <br /> �% { { �' PERMIT SUBMITTAL 03. <br /> 6' 31.2022 <br /> 'COMMONPATH=41'- 1 ) \\ _ dd (N)F&I OFFICE <br /> .- ) Y _ 1 PRICING UPDATE 08.09.2022 <br /> \ i ( 1 BLDG R <br /> � EVISION 09.30.2022 <br /> �x �( �\ vv �� /,1� �S ��� B 111SF 2PW REVISION 10.04.2022 <br /> pr � F <br /> 6" J /� �II 150 3 PLANNING/PW REVISION 11.23.2022 <br /> - <br /> P�--�7 Y�---)yam <br /> I I � I I \`, \�JI \ Typ / <br /> (N)F&I OFFICE <br /> (N)ENTRY <br /> B 120 SF <br /> VESTABLUE CD <br /> O®( �® ® ® 127 SF 0 ® ® ® ® ® _VV <br /> 00 o o ° o 0 <br /> Az <br /> ° o o ° ° <br /> z7 oc <br /> v W � <br /> DOOR WIDTH(IBC 1005.3) <br /> OCC LOAD FACTOR x OCC Q <br /> SHOWROOM CODE PLAN o a' a' 1s'� (0.2')x(27)=5.4"REQUIRED <br /> PROVIDED=36"CLEAR B <br /> A1.00 Scale:1/8"=T-O" <br /> SHOWROOM <br /> CODE PLAN <br /> A1 .00 <br />