Laserfiche WebLink
FREIHEIT <br /> ARCHITECTURE <br /> ROLL-UP DOOR ELECTRIC WALL ASSEMBLY — <br /> OPERATOR AND PER SECTION REFER TO BUILDING <br /> HEADPLATE;MOUNT PER PER MANUFACTURER ENVELOPE DETAILS FOR <br /> DOOR MFR.PROVIDE — WRAP SEQUENCING <br /> POWER PER BIDDER-DESIGN <br /> ELECTRICAL DRAWINGS. — EXTERIOR WALL PER PLAN <br /> _ II REFER TO DOOR SCHEDULE _ <br /> FOR ADDITIONAL =. WRB <br /> INFORMATION <br /> — SIDING PER ELEVATIONS <br /> K <br /> INSULATED 80X HEADER <br /> STOREFRONT JAMB;INSTALL <br /> PER ME STANDARDS ¢ — <br /> INSULATED BOX HEADER <br /> SEALANT AND BACKER ROD '.I — '.. _°•III <br /> METAL FLASHING W/ <br /> HSS BEAM;SIZE PER a — III _ FOLDED END DAMS <br /> STRUCTURAL METAL PANEL WALLASSEMBLY LL— — — <br /> _ SEALANT 8 BACKER ROD JOINT <br /> BREAK METAL PER PLAN hPER_ <br /> SEALANT AND BACKER ROD YSCHEDULE J <br /> LLI <br /> ALUMINUM WINDOW WALL HEAD SHIM 0 <br /> METAL HEADER TRIM <br /> INTERIOR EXTERIOR O <br /> HOLLOW METAL DOOR PER <br /> SCHEDULE <br /> NW <br /> L.L <br /> W <br /> o STOREFRONT CORNER STOREFRONT HEADER OVERHEAD DOOR @ FRAMED WALL EXTERIOR DOOR HEADER <br /> 1 / <br /> A6.03 Scale:3"=1'-0" A6.03 Scale:3"=V-O" A6.03 Scale: 1 1/2"=T-O" A6.03 Scale:3"=V-0" <br /> FRAME EXTENSION I WALL ASSEMBLY PER SCHEDULE INTERIOR Q <br /> FASTENER CAP BY WINDOW CORNER TRIM <br /> MANUFACTURER,MATCH REFER TO BUILDING <br /> WINDOW FRAME COLOR ENVELOPE DETAILS FOR <br /> INTERIOR GYP SHEATHING WRAP SEQUENCING O <br /> VAPOR RETARDER O <br /> SET CLIP IN SEALANT WALL ASSEMBLY PER TAPE EDGE <br /> BACKER ROD B SEALANT SCHEDULE JAMB n/ } <br /> BACKER ROD 8 SEALANT � < MO <br /> EXTERIOR WALL ----------- - O z CV <br /> PER SECTION <br /> o _ I• I 2_^ ww rn <br /> PREFINISHED METAL FLASHING W/ v Q <br /> FOLDED END DAMS <br /> 0 3: <br /> I OVERHEAD DOOR PER I w <br /> SIGNAGE PER MFR DOOR SCHEDULE .� z L> LU <br /> II CONTINUOUS WRB =— —— _ — ,e MANUFACTURER R DOOR N w WEATHER STRIP PE <br /> O <br /> HOLLOW METAL DOOR PER 00 L> <br /> INSULATED BOX HEADER <br /> -' STEEL ANGLE,PER STRUCTURAL SCHEDULE <br /> GLAZING PER ELEVATION DRAWINGS <br /> SET CLADDING TRIM IN <br /> PREFINISHED METAL FLASHING SEALANT BENT METAL PLATE.PAINT TO SHIM <br /> MATCH DOOR ABNJRB LAPPED <br /> OVER LINER 8 SEALANT AND BACKER ROD <br /> GARAGE DOOR PER SEALANT AND BACKER ROD ABMRB LAPPED WRB CLOSURE FLASHING AT BOTH SIDES <br /> OVER JAMB LINER <br /> INTERIOR SCHEDULE CLADING PER <br /> EXTERIOR CLADDING TRIM WITH ABNVRB LINER EXTERIOR WALL ELEVATION PREFINISHED MTL <br /> c HEMMED EDGE TO MATCH PER PLAN CLOSURE FLASHING <br /> ADJACENT CLADDING FINISH EXTERIOR SET IN BED OF <br /> CLOSURE TRIM BY EXTERIOR SEALANT <br /> PREFINISHED CLADDING TRIM CLADDING PER CLADDING MFR <br /> ELEVATION <br /> 11 SERVICE DRIVE SINAGE @ OVERHEAD DOOR STOREFRONT JAMB OVERHEAD DOOR JAMB @ FRAMED WALL EXTERIOR DOOR JAMB <br /> A6.03 Scale:3"=1'-0" I A6.03 1 Scale:3"=1,_O. I A6V.03 1 Scale:3"=T-0" I A6L.03 1 Scale:3"=V-O" <br /> VII <br /> a <br /> REGISTERED <br /> ARCHITECT <br /> PREFORMEDJOINT <br /> JOINT <br /> JAMB BEYOND E <br /> PAVING <br /> MICHAL J. L TON <br /> IN WALL DOWN PIPE VESTIBULE STOREFRONT <br /> VERIFY SLAB <br /> OVERHEAD DOOR CONCRETE STATE OF WASHINGTON <br /> SLOPE BREA K DISTA SLOPE PER CIVIL <br /> PAINTED GYPSUM WALL BOARD TYPE"W EXTERIOR RELATNE TO BACKSIDE OF 1/4"PER FOOT <br /> / OVERHEAD DOOR <br /> INTERIOR WALL PER SCHEDULE FRAME EXTENSION I TOP OF SLAB ISSUE LIST <br /> \ FASTENER CAP BY GLAZING PER ELEVATION <br /> WINDOW PERMIT SUBMITTAL 03.31.2022 <br /> MANUFACTURER,MATCH PRICING UPDATE 08.09.2022 <br /> HSS COLUMN BY STRUCTURAL WINDOW FRAME COLOR PRE FINISHED MTL CONCRETE - INTERIOR EXTERIOR 1 BLDG REVISION 09.30.2022 <br /> CLOSURE FLASHING FOOTING PER HIMDOOR PRE FINISHED MTL 2 PW REVISION 10.04.2022 <br /> STRUCTURAL _ CLOSURE FLASHING 3PLANNING IPW REVISION 11.23.2022 <br /> �� _ _ _ _ FABRICATED SILL PAN EXPANSION JOINT, <br /> EXTERIOR STORFRONT(BY OTHERS) SEALANT AND WEEP PER FABRICATED SILL PAN EXPANSION JOINT, <br /> F l - " <br /> ALIGN MANUFACTURER WEEP PER <br /> L———————J - BACKER ROD AT SEALANTAND MANUFACTURER <br /> INTERIOR .-, .-,_,-.- INTERIOR BOTH SIDES WATER PROOFING,TYP. - -: BACKER ROD AT <br /> ` WATER FLOOR FINISH PAVEMENT PER PLAN _ III III III BOTH SIDES PROOFING,TVP. <br /> PAVEMENT PER <br /> PER PLAN III=III III III—III III III III—III \ FLOOR FINISH R PLAN <br /> =1 III -1 III III = PER PLAN <br /> SLOPE MAX 2% _ _ _ <br /> — — — — — _ <br /> IIIIIIIIIIIIIIIIIIIIII�IIIIIIIIIIIIIIIIIIIIIII�IIIIIIIIIIIIIIIIIIIIII IIIIIII <br /> SLOPE MAX 2% <br /> I <br /> a II=III III III—III=III III III=III III III—III=III III III <br /> EXTERIOR EXTERIOR •"r n. =III= III = III = = III = III <br /> I 11=III=III=III=III=III=III=III=III=III=III=III=III=III=III=III=III=III=11 <br /> =III=III=III=III=III=III=III=III=III=III=III=III=III=1"=III="'=III=" •."J-`°�' <br /> a IIIIII III—III—III—III—III—III—III—III—III—III—III—III- I - <br /> -1 -11-1 -11-1 -11-1 -11-1 -11-1 -1 -1_ <br /> EXTEIOR DRAIN SUPPER <br /> =III=III=III—III=III—III=III—III=III—III=III—III—III— III III III III <br /> =I 1=1I 1=1 11=1I1=1 11=1I1=1 11=1I1=1 11=1I1=1 11=1 11=1 11=III—III—III—III=III—III=III—�I o <br /> G I I I I I 1=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1I 1=1 11=1I1=1 11=1I1=1 11=1I1=1 11=1I1=1 11=1 <br /> N <br /> 12 FURRING @ ENTRY VESTIBULE STOREFRONT SILL GARAGE DOOR THRESHOLD TYP.DOOR TRANSISTION <br /> A6.03 Scale: "1 1/2"=1'-0 I A6.03 1 Scale:3"=V-O" I A6`•.03 1 Scale: 1 1/2"=T-O" I A6y.03 1 Scale:3"=V-0" OPENING DETAILS <br /> A6.03 <br />