My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7800 EVERGREEN WAY HYUNDAI 2025-08-22
>
Address Records
>
EVERGREEN WAY
>
7800
>
HYUNDAI
>
7800 EVERGREEN WAY HYUNDAI 2025-08-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2025 8:31:28 AM
Creation date
7/17/2025 11:29:27 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7800
Tenant Name
HYUNDAI
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FREIHEIT <br /> ARCHITECTURE <br /> PARTITION WALL <br /> PER PLAN <br /> PERIMETER EDGE <br /> ANGLE CLIP <br /> \ � o <br /> 8"MAX :�,SEISMIC CLIP o SEISMIC CLIP <br /> n <br /> � � J <br /> ,,Z , SUSPENDED 0 <br /> 718 T/8" ACOUSTICAL CEILING O <br /> `e�m `4B4 PER RCP CC <br /> `4 4 ui <br /> "ATTACHED WALL" a "UNATTACHED WALL" <br /> OPTION OPTION — W <br /> 4 CEILING PERIMITER ANGLE CLIP 1 CEILING @ WALL <br /> A6.10 Scale:3"=T-0" A6.10 Scale:3"=V-0" Q <br /> Z <br /> Q <br /> O <br /> L.1_ }} <br /> 10 GAWIRE HANGERS AT <br /> 8"MAX. PERIMETER SUPPORTING <br /> CONTINUOUS ANGLE AT WALL MAIN RUNNERS AND CROSS O z <br /> EDGE TYPICAL RUNNERS 8"MAX FROM EDGE.RECESSED LIGHT FIXTURE !2 Lw 6) <br /> (WHERE OCCURS) vJ Q <br /> 10 GA HANGER WIRES AT 4'-0" MAIN RUNNERS:1 112" ^ � <br /> CEILING/SOFFIT HEADER FRAMING > <br /> ON CENTER MAXIMUM EACH COLD ROLLED CHANNELS i <br /> WAY(TYPICAL) AT 4'-0"ON CENTER `L <br /> MAXIMUM 70 LLI <br /> \ AT FURR NG�V L L>LI LLI <br /> CANNEL AT 2'-0" <br /> O.C.MAX. NO LLI <br /> 10 GA LATERAL BRACING WIRES = - LLU <br /> 2'-0"MAXIMUM FROM CANNEL <br /> INTERSECTION AT 518"TYPE GWB PER <br /> APPROXIMATELY 45'IN EACH 5 REFECTED CEILING PLAN <br /> DIRECTION.LOCATED ON A V,0' <br /> I <br /> X 12'-0"O.C.GRID AND A MAX. <br /> 6-4-FROM WALLS. ACCESS PANEL W/ <br /> FLANGE TRIM.RATED <br /> WHERE REQ'D <br /> FLUSH W/FINISHED CEILING <br /> CEILING/SOFFIT <br /> CONSTRUCTION PER SECTION <br /> I <br /> SUSPENDED GWB CEILING 7 RECESSED LIGHT FIXTURE @ CEILING <br /> A6y.10 1 I 1 Scale:1/4"=V-01' A6'10 Scale:3"=V-0" <br /> 3 <br /> REGISTERED <br /> ARCHITECT <br /> TO STRUCTURE ABOVE � -/ <br /> INSTALL#12 GA.VERTICAL WIRE AT 4'-O"O.C. <br /> CONNECTED TO MAIN RUNNER&STRUCTURE MICHAEL J. L TON <br /> ABOVE.INSTALL AN APPROVED COMPRESSION <br /> POST FLUSH WITH TOP OF CLG.GRID& STATE OF WASHINGTON <br /> G F STRUCTUREABOVE. <br /> SPRING CLIP <br /> ISSUE LIST <br /> CROSS RUNNER PERMIT SUBMITTAL 03.31.2022 <br /> INSTALL#12 GA.WIRE CROSS BRACING IN PRICING UPDATE 08.09.2022 <br /> 45 EACH PLANE OF MAIN RUNNER AT 12'-O"O.C. 1 BLDG REVISION 09.30.2022 <br /> DEGREES AT 45 DEGREE ANGLES IN BOTH DIRECTIONS 2 PW REVISION 10.04.2022 <br /> TYP WITH THE FIRST POINT WITHIN 6'-O"FROM 3 PLANNING/PW REVISION 11.23.2022 <br /> EACH WALL. <br /> MAIN RUNNER <br /> CROSS RUNNER <br /> MAIN RUNNER <br /> I I <br /> .iaaur 2'-8" 9'-8" 2'-8" 1.NOTE <br /> INSTALL AS REQUIRED UNDER AS <br /> ASTM C635 <br /> .iipur &C636 PER IBC 2504&N.W.C.B. <br /> TECHNICAL DOCUMENT#401 <br /> 2.SUPPORTING WIRES TO BE <br /> M <br /> GUAGED AND SPACED PER ASTM C841 <br /> TABLE 3. a <br /> 3.PROVIDE LIGHT FIXTURE SUPPORT <br /> ATTACHMENT PER ASTM E580. <br /> SHOWROOM CEILING TRANSISTION DETAIL SUSPENDED CEILING BRACING <br /> As.10 Scale:1 Scale:3"=V-0" CEILING DETAILS <br /> A6.10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.