My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3620 W MUKILTEO BLVD C 2023 HARBORS EDGE TOWNHOMES Plans 2025-07-22
>
Address Records
>
W MUKILTEO BLVD
>
3620
>
HARBORS EDGE TOWNHOMES
>
Plans
>
3620 W MUKILTEO BLVD C 2023 HARBORS EDGE TOWNHOMES Plans 2025-07-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2025 9:08:16 AM
Creation date
7/18/2025 7:34:18 AM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
3620
Unit
C
Tenant Name
HARBORS EDGE TOWNHOMES
Permit
B2304-040
Year
2023
Notes
NEW "HARBOR'S EDGE" TOWNHOMES, UNIT C
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WRITTEN DIMENSIONS ON TH15 DRAWING SHALL HAVE FREOBDBNOE OVER SOALED DIMENSIONS. <br /> CONTRACTOR SHALL VERIFY ALL DIMENSIONS,CONDITION5,ETC.PERTAINING TO THE WORK <br /> BEFORE PROCEEDING.THE OWJER I—T BE NOTI 1 D OF ANY VARIATIONS FROM THE <br /> DIMENSIONS AND/OR CONDITIONS SHOWN ON THESE DRAWINGS.ANY SUCH VARIATION SHALL BE <br /> OR TIP CONTRACTOR 5HALL <br /> ACCEPT FULL RESPONSIBI_FOR THE COST TO RECTIFY SAME. M� <br /> �II��wAYve.u»I <br /> I I I I I I <br /> I I I I <br /> G.F.I. TO <br /> I O <br /> O O POCKET <br /> KITCHEN OFFICE <br /> IIII PRIMARY <br /> BEDROOM <br /> L —J I \ IIII o BATH <br /> CEILING <br /> MOUNTED PEND. <br /> RDUPLEX <br /> EGEPTAGLE G.FII. 1 O IIII ___ U c fi <br /> GARAGE / AIR HANDLER N LIGN✓O O <br /> DUCTLESS VT �60.11 <br /> .F.I. PEND. MINI-SPLIT 50.CFM CRANK <br /> I TIME2 FTI <br /> /J W.H.FAN <br /> 2 o vro <br /> GFMO -- W <br /> O m <br /> m BATHROOM HEAT NOTE: m <br /> HEAT i DINING / r— — *TOE KICK HEATERS TO IIa Z <br /> DETECTOR INSTALLED IN <br /> r——— ROOM BATHROOMS(ELEGTRIG) OO 'I 8 <br /> ___ AIR HANDLER r�NoO G.F.I. P <br /> MINI SPPLLLIIT 5Y5TEM TO /X� <br /> vYo AND E w�6o BATH L II <br /> Ic,HkFM BATH O ——— ®L cRArvK i <br /> pl�gp TIMER <br /> I^G 6a Ml SWIT i� Ilov S.D. <br /> TIMER\ �� IIPi 5. — � E Q o <br /> __ / O SWIT <br /> ----- O FLR.1 \1TJ• FIX ------ JTMJP�' <br /> FLR. W <br /> I Q I Q <br /> ELEG.HEAT U W L— <br /> FuHF HATER GREAT <br /> HEATER <br /> oa ROOM IIII BEDROOM <br /> IIII FOY R IIII TNO LOFT <br /> IIII BEDROOM li O.D. O LL o I "' to <br /> II k� FOUR -a m I I II k 1J�__i❑O ,/vim` <br /> III I WWp N L I(]I, ( / IIII AIR HANDLER <br /> DUCTLESS <br /> III F COVERED I IIII MINI-5PLIT �+ ' <br /> a')z \\ PORCH O <br /> Q p f rnl cDrCKEV ICI O <br /> LLII DECK LJ <br /> _ tL <br /> L:OWAR r-LOOR PLAN MAIN fL:OOR PLAN UPPER FLOOR PLAN � Z <br /> 5GALE: 1/4" I'-O" 5GALE: I/4" I'-0" 5GALE: I/4" I'-0" Q <br /> L <br /> Q Q <br /> data: -30-20 <br /> pormit: <br /> ravlsIns: <br /> ELEGTRIGAL NOTES: ELEGTRIGAL LEGEND: 6-1�-28 <br /> O LOW VOLTAGE LIGHTS � DOOR AT AL SL015ETs <br /> I.INSTALLATION OF BOTH PHONE AND TV SHALL 10.PROVIDE TAMPER-RE515TANT REGEPTACLE5 IN EVERY 110 VOLT WALL CONVENIENCE OUTLET <br /> PROVIDE ALL OUTLETS TO BE RUN A5 HOME $ 110 VOLT SMOKE <br /> RUNS WITH ALL WIRES TERMINATING AT A SINGLE KITCHEN,FAMILY ROOM,DINING ROOM,LIVING ROOM, HEAT LAMP Q DETECTOR <br /> JUNCTION LOCATION IN EITHER THE HOUSE/UNIT OR PARLOR,LIBRARY,DEN,SUNROOM,BEDROOM,RECREATION $ 110 VOLT WALL GONIVEINIENGE OUTLET INrERcoNNEcrED <br /> GARAGE ROOM,OR 51MILAR ROOM OR AREA OF DWELLING UNITS .P.I. WITH GROUND FAULT INNTERUPTOR ® UNDERWATER LIGHT <br /> 2.PHONE/TV-GAT 5-ROUGH IN ONLY,GABLE PER NEC 406.12. <br /> COMPANY PROVIDES TRIM 220 VOLT WALL GONVENIENGE OUTLET O° GABLE OUTLET <br /> II.RECEPTACLE AT GARAGE GEILIN6 SHOULD BE NOTED ❑O REcessED u(SHT FIXTURE <br /> 5.RANGE TO BE WIRED FOR 220v 61'GI AS REQUIRED BY NEG210.5.THIS OUTLET 15 OFTEN $ 110 VOLT WEATHERPROOF OUTLET WITH GAP O COMPUTER CIRCUIT <br /> W.P. <br /> 4.FAN SIZES: USED FOR PORTABLE LIGHTING AND POWER TOOLS.WHERE ❑v DIRECTIONAL REGE55ED dr byy: LMI7 <br /> B dy <br /> POWDER ROOM-50 GFM WITH 50 MINUTE CRANK TIMER HABITABLE SPACE ABOVE,OUTLET BOX SHALL BE STEEL $ 110 VOLT SPLIT WIRED C ET.V. wn CONVENIENCE OUTLET LIGHT FIXTUR O TELEPHONE, a T. .GABLE dra Nn L <br /> BATHROOMS-50 GFM FAN/LIGHT COMBO WITH 60 OR FIRE-RATED EQUIVALENT.GOMPLY WITH IRG R502.4.2 y: MWJ <br /> MINUTE CRANK TIMER FOR MEMBRANE PENETRATIONS.THE ANNULAR SPACE ® 110 OR 220 VOLT SPECIAL PURPOSE OUTLET SURFACE MOUNTED STRIP FIXTURE UTILITY <br /> TELEPHONE OUTLET <br /> UTILITY ROOM- 150 GFM WITH 24 HOUR PROGRAMMABLE <br /> TIMER BETWEEN THE WALL MEMBRANE AND THE BOX SHALL NOT SI--f�ET <br /> 5.PROVIDE 200 AMP CIRCUIT BREAKER PANEL EXCEED ". GEILIN6 MOUNTED LIGHT FIXTURE QFANN G.F.M.FAN <br /> YY (VENT TO OUTSIDE) <br /> FLUORESCENT <br /> 6.TYPES AND LOCATIONS OF LUMINAIRES IN CLOTHES 12. WRED IN CIRCUIT INTERRUPTER PROTECTION IS u�Hr cH1MEs <br /> CLOSETS SHALL COMPLY WITH NEC 410.16. LIMN RED IN KITCHENS,FAMILY ROOMS,DINING ROOMS, PENDANT u-Hr F1x71RE <br /> LIVING ROOMS,PARLORS,LIBRARIES,DENS,BEDROOMS, � PeN <br /> KD. <br /> 7.REGE55ED LUMINAIRES INSTALLED IN THE BUILDING 5UNROOM5,RECREATION ROOMS,CLOSETS,HALLWAYS, 7 HALL MOUNTED LIGHT FIXTURE(OR SCONCE) S-ITGH EID DooRBELL <br /> THERMAL ENVELOPE ARE SUBJECT TO THE PROVISIONS OF LAUNDRY AREAS,OR SIMILAR ROOMS PER NEC 210.12(A). <br /> IRG N1102.4.5.FIXTURES SHALL BE IG-RATED(FOR ZERO Pc WALL MOUNTED LIGHT FIXTURE WITH SINGLE POLE <br /> WITH DI SWITCH THERMOSTAT <br /> CLEARANCE INSULATION CONTACT)AND SEALED AIR TIGHT. PULL CHORD DIM. MMER DEVICE <br /> 5.DWELLING UNIT REGEPTAGLE OUTLETS SHALL BEB THREE HAY SWITCH FLOOD LIGHT <br /> INSTALLED SUCH THAT NO POINT MEASURED HORIZONTALLY + GEILIN6 FAN PRE-HIRE <br /> ALONG THE FLOOR LINE OF ANY WALL SPACE 15 MORE <br /> 4 B GAS OUTLET <br /> THAN 6'REGEPTAGLE OUTLET PER NEC 210.52(A)(1). FOUR HAY SWITCH <br /> PROVIDE ADDITION RECEPTACLES ON PLAN AS REQUIRED <br /> 9.LUMINAIRES IN NET OR DAMP LOGATIONS SHALL BE <br /> MARKED SUITABLE FOR WET OR DAMP LOGATIONS PER NEC <br /> 410.10.THIS INCLUDES FIXTURES MOUNTED OVER TUBS AND <br /> SHOWERS. <br />
The URL can be used to link to this page
Your browser does not support the video tag.