My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3301 SEAWAY BLVD MAGNIX 2025-08-20
>
Address Records
>
SEAWAY BLVD
>
3301
>
MAGNIX
>
3301 SEAWAY BLVD MAGNIX 2025-08-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/20/2025 9:14:28 AM
Creation date
7/18/2025 8:55:38 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
3301
Tenant Name
MAGNIX
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2023 NEEA, All rights reserved <br /> 'The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycod s.com <br /> S <br /> C405.2.1.2 Occupant sensor Indicate each aisleway and corridor within a <br /> controls-warehouses warehouse space are designated as separate <br /> spaces zones that are independently controlled <br /> Indicate occupant sensors are configured to <br /> automatically reduce lighting power by 50% <br /> when the zone is unoccupied and 100%off <br /> after the zone is unoccupied for over 20 <br /> minutes;indicate controls are configured to <br /> automatically restore lighting to full power <br /> when the zone or space is occupied <br /> C405.2.1.3 Occupant sensor For open plan office areas Iarger than 300 sf, <br /> controls-open plan indicate general lighting is provided with <br /> office areas vacancy controls that reduce lighting power by <br /> not less than 80%and are configured to turn <br /> luminaires 100%off when the space is <br /> unoccupied;indicate that no individual control <br /> zone area exceeds 600 sf <br /> C=0,15.2.1.. vcc pant sen:3or Ii,c'cic tv 2:.3?'1<?lLr c�`c ri;i,vT'1' T 13 <br /> cont-cols-parking pronid'ed vaca3[i:_y <br /> garages I'- .iC2?po-, oT by not 1-6�uh.an.JV,'.-and cLr: <br /> con lotum lt.,ninaires I 00%off--l1Cia <br /> 110 ve„iclws or ped.st.na-ns are pre en,.j nie.,s <br /> a iai le br an ex--fp ion;in,ic.-ae 6-ia3:,ie <br /> individual controi zone area--,�cecds ,600 sf <br /> C405.2.1.5 Occupant sensor Indicate stairway lighting is provided with <br /> controls-enclosed vacancy controls that reduce lighting power by <br /> fire-rated stairwells not less than 501%when the stairway in <br /> unoccupied <br /> C405.2.2.1 Automatic time Indicate spaces on plans where time switch <br /> switch controls controls turn luminaires 100%off during <br /> unoccupied hours <br /> Indicate spaces on plans where time switch <br /> controls are configured to turn on lighting to <br /> full power versus 50%power <br /> Indicate locations of override switches on <br /> plans and the lighting zone(s)served;indicate <br /> that the area(s)served by each override switch <br /> does not exceeds 5,000 sf <br /> C405.2.1, Digital timer switch Indicate digital timer switch control includes: <br /> Exception 3 manual on/off,time delay,audible and visual <br /> indication of impending time-out <br /> C405.2.4.2 Daylight zones- Indicate primary and secondary sidelit <br /> C405.2.4.3 Sidelit and toplit daylight zone floor areas on plans <br /> Indicate toplit daylight zone floor areas on <br /> plans <br /> For small vertical fenestration assemblies <br /> (rough opening less than 10 percent of <br /> primary daylight zone floor area)where <br /> daylight responsive controls are not required, <br /> provide fenestration area to daylight zone <br /> floor area calculation(s) <br /> Pace 211 D <br />
The URL can be used to link to this page
Your browser does not support the video tag.