2018 WSEC Requirements for Commercial BLfldinas including Group R2.R3&R4 over 3 stories&all R1 -- Administered by©2023 NEEA,Ali rights reser✓ed <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C405.i ulec ica? ir,c1 :c vJe xica"ttr 'S'omier schedule On <br /> transiorr.ers etc--cica;ct ns:in I.—te tran.sfolraerq PC <br /> Si7ci cfi icieiici-,or exception.taker <br /> C405.11 Feeders and branch Provide documentation that demonstrates <br /> circuits maximum voltage drop across feeders and <br /> branch circuits does not exceed 5% <br /> C405.7 31t affi.ng unit ipdi.cate on elecuical pla-is 11Rat each d:veLirg <br /> elecuacal aner`y Unit in Group R-2 bas a separate electrjcal <br /> C011saklip-d Qom. ener-OV <br /> C405.8 E114cuic Inotor Include all motor&inclu-ing fractional hr <br /> ettim enctl motors.in ele,iri.'c motor whedL''_e on <br /> rno"Or <br /> hoi'sepower.rpm,rai TiC3tuC;l,or <br /> exception applied <br /> C405.9.1. E e-ator cabs -or'umnirair_s in each elevator cab_provide <br /> calculations tbat demonstrate:average efficacy <br /> :S not less tban 35 lunie J per°watt <br /> Gor elevators Cliat do not have-an inter,al a.r <br /> conditioning system.indicate rated 1.vaus per <br /> cirri"or elevator cab ventilation.fags do not <br /> exceed 0.3-N ratts per chn <br /> Indicate automatic controls that de-enernnze <br /> Lighting and ventilationventilation fans w✓ en elevator is <br /> stopped and unoccupied for a period of 15 <br /> minlLtes or:wore <br /> C t05.9.2 Escalat?rc•and i.ndicalEe es-calators,comp? with.ASNIE <br /> moving"walks A.1 1.i;C.SA B44;aucomadc-on rrois are <br /> confi- ed to re duce operational speed to the <br /> minimum pema fitted w1hen_not in use <br /> C4305.9.3 regenerative drive Indicate afi one-may,down or re era hie <br /> ` malaton are p'ovi led vv'ith a variable <br /> frequency regenera five drive <br /> DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT coNMUSSIONING(CX) <br /> C408.4 Scope of electrical Indicate that all electrical systems <br /> power and lighting (receptacles,transformers,motors,vertical <br /> systems and horizontal transportation)for which the <br /> commissioning WSEC requires control functions and/or <br /> configuration to perform specific functions <br /> are required to be commissioned <br /> Where total building lighting load is>20 kW, <br /> or where total lighting load of luminaires <br /> requiring daylight sensing and/or occupancy <br /> control>10 M indicate that all automatic <br /> lighting control systems are required to be <br /> commissioned;or provide building lighting <br /> power calculation demonstrating eligibility for <br /> exception <br /> C405.13 Commissioning Indicate Cx requirements in plans and <br /> C408.1.1 requirements in specifications for all applicable electrical and <br /> C408.1.2 construction lighting control systems per C408 <br /> C408.1.4.2 documents <br /> C103.6.3 <br />_......_.._.... - -...._.. ................ . Paae 9110 <br />