My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-23 2025-08-15
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-23
>
3003 W CASINO RD BLDG 40-23 2025-08-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2025 11:50:08 AM
Creation date
7/18/2025 9:48:43 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-23
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1.0 PURPOSE <br /> The purpose of these inspections and tests is to provide assurance that custom <br /> or non-certified equipment meets the requirements of the appropriate codes, <br /> safety orders and industry standards. These inspections and tests are normally <br /> required by the local building inspection authority having jurisdiction (AHJ) when <br /> equipment has not been certified by a Nationally Recognized Testing Laboratory <br /> (NRTL) or other recognized testing agency. These inspections address only the <br /> electrical systems on the equipment listed in Section 5.0 of this report. <br /> 2.0 SUMMARY <br /> This project was initiated at the request of Mr. Jacob Chabot with <br /> ELECTROIMPACT INC. Inspections, testing and labeling of the equipment <br /> referenced in Section 5.0 was performed at the Boeing 40-23 Building in Everett, <br /> WA by eti Conformity Services Compliance Engineer Donald Preiss on May 24, <br /> 2023 and June 7, 2024. <br /> This equipment and scope is part of the HBL cells labeled by eti in 2018 and <br /> included some new pieces. <br /> No electrical discrepancies were observed during the inspection and testing of <br /> the equipment. Field measurements were taken by eti Conformity Services as <br /> detailed in Section 8. These measurements were determined to be within the <br /> manufacturer's and standard's specifications. eti Conformity Services considers <br /> this equipment to be in compliance with the electrical codes and standards listed <br /> in Section 4.0, pursuant to the conditions of acceptance described in Section 3.0. <br /> An eti Conformity Services evaluation label has been affixed to the equipment. <br /> Note that final approval is under the jurisdiction of the City of Everett. <br /> Ell has been verified as a Non Vertiv Company. <br /> 3.0 GENERAL CONDITIONS OF ACCEPTANCE <br /> In the event of modifications resulting in a change in the materials, manufacturing <br /> methods, loading, or environment that would affect the use of the accepted <br /> equipment under the provisions of the noted electrical standards, this acceptance <br /> will be considered automatically canceled. The applicant will be required to <br /> request re-examination of this equipment to determine acceptability of the <br /> modifications. <br /> By acceptance of the equipment referenced in Section 5.0, eti Conformity <br /> Services does not assume or discharge the responsibility of the equipment <br /> manufacturer, installer, or other relevant parties. Equipment evaluation is based <br /> upon adherence to sound engineering practices, and upon compliance with the <br /> Reference No.: 1108546 Page 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.