My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-23 2025-08-15
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-23
>
3003 W CASINO RD BLDG 40-23 2025-08-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2025 11:50:08 AM
Creation date
7/18/2025 9:48:43 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-23
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
110.9 Interrupting Rating. <br /> "Equipment intended to interrupt current at fault levels shall have an interrupting rating <br /> sufficient for the nominal circuit voltage and the current that is available at the line <br /> terminals to the equipment." <br /> "Equipment intended to interrupt current at other than fault levels shall have an <br /> interrupting rating at nominal circuit voltage sufficient for the current that must be <br /> interrupted." <br /> 110.16 Flash Protection. <br /> "Switchboards, panelboards, industrial control panels, meter socket enclosures, and <br /> motor control centers that are in other than dwelling occupancies and are likely to require <br /> examination, adjustment, servicing, or maintenance while energized shall be field marked <br /> to warn qualified persons of potential electric arc flash hazards. The marking shall be <br /> located so as to be clearly visible to qualified persons before examination, adjustment, <br /> servicing, or maintenance of the equipment." <br /> eti Conformity Services would be happy to provide a proposal for above <br /> services upon receiving a request from the customer. <br /> 6.6 Internal Wiring <br /> Internal wiring and wiring methods are evaluated for compliance with the <br /> applicable codes and standards referenced in Section 4.0. Wiring is <br /> verified to be properly sized and rated, with a temperature rating suitable <br /> for the installed application. <br /> 6.7 Safety Interlocks and Operator Controls <br /> The equipment safety interlocks, emergency stops, operator controls and <br /> human machine interfaces (HMI) are verified to be properly identified. The <br /> safety features and emergency machine off (EMO) switches are tested for <br /> proper operation. <br /> 6.8 Field Testing <br /> Field testing is performed on the equipment, to meet the field testing <br /> requirements of the standards referenced in Section 4.0, unless <br /> production test results have been provided by the equipment manufacturer <br /> and accepted by eti Conformity Services. If no production tests are <br /> submitted, then testing is performed to verify the equipment to be <br /> operating within normally expected parameters as detailed in Section 8.0. <br /> Reference No.: 1108546 Page 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.