My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4849 SPIRE LN 2023 2025-07-18
>
Address Records
>
SPIRE LN
>
4849
>
4849 SPIRE LN 2023 2025-07-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2025 3:49:02 PM
Creation date
7/18/2025 3:48:29 PM
Metadata
Fields
Template:
Address Document
Street Name
SPIRE LN
Street Number
4849
Year
2023
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Proposed Remedial Excavation: 4849 Spire Lane,Everett,WA <br /> December 8,2022 <br /> underpinning the section of the south foundation wall adjacent to the proposed excavation. <br /> The underpinning should also extend past the limits of the excavation by at least 5 feet. <br /> In our opinion, small diameter driven steel pipe piles represent a feasible foundation <br /> underpinning option in terms of cost and long-term performance. Small diameter driven <br /> steel pipe piles may be utilized to support the structure by transferring the foundation loads <br /> to the underlying dense to very dense soils. Pipe piles of 2 to 4 inches in diameter are <br /> typically utilized for this purpose. 2-inch pin piles are typically installed using portable, <br /> handheld equipment and are suited for areas where limited site access exists or in low <br /> headroom areas. 3-inch and 4-inch pin piles are typically installed using small hammers <br /> mounted on a small to medium-sized excavator. <br /> Pin Pile Size—Because the piles will need to be installed directly adjacent or under the <br /> existing building footing,and because foundation loads are anticipated to be relatively low, <br /> we anticipate that 2-inch diameter pin piles would be used for this project. <br /> Pin Pile Capacity-The number of piles required depends on the magnitude of the design <br /> load and the capacity of the existing footing to span between the piles. 2-inch diameter pin <br /> piles are typically installed with a 90-lb jackhammer with the operator leaning heavily on <br /> the hammer during driving, or a 140-lb jackhammer (often referred to as a "rhino" <br /> hammer). We recommend that an allowable axial compression capacity of 3 tons per pile <br /> be utilized for design, with an approximate factor of safety of 2.0 when piles are driven to <br /> practical refusal (less than 1 inch of penetration for 1 minute of continuous driving). <br /> Tensile capacity of pin piles should be ignored in design calculations. <br /> It is our experience that the driven pipe pile foundations should provide adequate support <br /> with total settlements on the order of%2-inch or less. <br /> Pin Pile Specifications -We recommend that the following specifications be included on <br /> the project plans: <br /> 1. 2-inch diameter piles should consist of Schedule-80, ASTM A-53 Grade"A"pipe. <br /> 2. 2-inch piles shall be driven to refusal with a 140-lb jackhammer or a 90-lb hammer <br /> with the operator leaning heavily on the hammer during driving. Refusal is defined <br /> as no more than I inch of penetration for 1 minute of continuous driving. <br /> 22-389_4849 spire lane everett rpt.docx Page 6 PanGEO, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.