My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
16 76TH ST SW 2025-08-20
>
Address Records
>
76TH ST SW
>
16
>
16 76TH ST SW 2025-08-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/20/2025 1:33:16 PM
Creation date
7/21/2025 1:29:54 PM
Metadata
Fields
Template:
Address Document
Street Name
76TH ST SW
Street Number
16
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OPERATION <br /> In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is <br /> released at once.As a result, the Deflector drops down to the intended position.Two Heat Collectors are exposed to fire, <br /> and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water <br /> flow to be distributed on the affected fire area. (Ref. Figure 2) <br /> Normal Condition Cover Plate Operation Sprinkler Operation Water Discharge <br /> Figure 2:Operation Process (For illustrative purposes only) <br /> DESIGN CRITERIA <br /> The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly <br /> implemented for safe and full results. <br /> Notes <br /> Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with <br /> automatic sprinkler system design, installation procedures,and techniques. <br /> Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler <br /> system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the <br /> sprinkler system. <br /> Questions concerning sprinkler installation and usage criteria,which are not covered by the following instructions, should be <br /> submitted to your contracted company. Include sketches and technical details,as appropriate. <br /> In some instances,the requirements of this document may concern specifications which are more stringent, and which take <br /> precedence over those specified in NFPA 13, 13D, 13R,or by the authority having jurisdiction. <br /> The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. <br /> Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup <br /> are open and free from any air flow impediment. <br /> The spray from the sprinkler is distributed radially outward and downward from the sprinkler deflector. Consequently, the <br /> sprinklers must be located such that there will be no blind spaces shielded from spray by partitions,room dividers,overhangs <br /> or other parts of the dwelling structure. <br /> The number of sprinklers within each compartment(as defined by NFPA 131D,13R,or 13)must be kept as few as possible while <br /> observing all guidelines relating to obstructions and spacing. <br /> Use only the Cover Plate provided for the Model RC-RES. The sprinkler must be secured in place by firmly fastening the <br /> sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from <br /> sprinkler operation could alter its orientation and its water distribution pattern. <br /> 40 www.senjusprinkler.com Page 3 of 8 Document No.U085168• 02-08-2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.