Table A. NFPA 13D & 13P Wet Pipe Hydraulic Design Criteria for Model SS8464 <br /> For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as <br /> applicable. <br /> Maximum Maximum Ordinary Temperature Intermediate Temperature <br /> Coverage Spacing Rating 162°F(72°C) Rating 205°F(96°C) Deflector to Installation Minimum <br /> Area(,) Spacing <br /> Ft.xFt. Ft' Flow(b)GPM PressureN Flow(b)GPM Pressure"� Ceiling Type Ft.�m) <br /> (m x m) (m) (LPM) PSI(bar) (LPM) PSI(bar) <br /> 12 x 12 12 13 7.0 13 7.0 Smooth <br /> (3.7 x 3.7) (3.7) (49.2) (0.48) (49.2) (0.48) Ceilings 3/8 <br /> to 7/8 Inches. <br /> 14 x 14 14 13 7.0 13 7.0 <br /> (4.3 x 4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Beamed <br /> Ceilings per <br /> 16 x 16 16 13 7.0 13 7.0 NFPA 13D, Concealed 8 <br /> (4.9 x 4.9) (4.9) (49.2) (0.48) (49.2) (0.48) 13R or 13. (2.4) <br /> 18 x 18 18 17 12.0 17 12.0 Installed in <br /> (5.5 x 5.5) (5.5) (64.4) (0.83) (64.4) (0.83) beam 3/8 to <br /> 7/8 inches <br /> 20 x 20 20 21 18.4 21 18.4 below bottom <br /> (6.1 x 6.1) (6.1) (79.5) (1.27) (79.5) (1.27) of beam. <br /> a. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next <br /> Higher Coverage Area listed. <br /> b. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are <br /> calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. <br /> Sprinkler Spacing Criteria <br /> The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond <br /> the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) <br /> INSTALLATION <br /> The Model RC-RES must be installed in accordance with the following instructions: <br /> NOTES <br /> Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show <br /> deformation or cracking in either the Sprinkler or the Protective Cap. <br /> Prior to installation,sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for <br /> damage to the sprinklers that could cause improper operation or non-operation. <br /> The Protective Cap must remain on the sprinkler during installation.After the installation is completed,the Protective Cap must <br /> be removed to place the sprinkler in service. <br /> Use a torque of 7 to 14 ft•lbs(9.5 to 19.0 N•m)to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum <br /> torque,this could result in damage to the sprinkler inlet,which may lead to leakage from the sprinkler. <br /> Use only NR-H model wrench socket for installation of RC-RES sprinklers. Use of any other wrench or socket is prohibited and <br /> may cause damage to the sprinkler. <br /> In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make <br /> any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. <br /> Do not rotate the Cap Removal Tool for RC to the left with force when placing the two hook arms into place.The installed sprinkler <br /> may become loosened,which may cause water leakage. <br /> 40 www.senjusprinkler.com Page 5 of 8 Document No.U085168• 02-08-2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.