My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
202 ALDER ST 2023 Plans 2025-08-07
>
Address Records
>
ALDER ST
>
202
>
Plans
>
202 ALDER ST 2023 Plans 2025-08-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2025 8:17:53 AM
Creation date
7/22/2025 8:17:27 AM
Metadata
Fields
Template:
Address Document
Street Name
ALDER ST
Street Number
202
Permit
FA2308-012
Year
2023
Notes
FIRE ALARMS IN PORTABLE CLASSROOM ADD
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
converg;nt' <br /> convergInt" 450 Shattuck Avenue South,Renton,Washington 98057 <br /> Phone:425-272-2250 Fax:425-251-0949 <br /> This dooument and the information/depictions oantained/shown <br /> Is the exduslve pmpedy of Convergint Technologies LLC and shall <br /> be handled as proprietary antl confidential information antl must be <br /> returned upon request.This document cannot be reposluoetl by any <br /> ,eans without the written suthodutlon of Convergint Teohnologles LLC. <br /> EVERETT SD - VIEW RIDGE ES <br /> PORTABLES P3, P4, P5 <br /> 202 ALDER STREET, EVERETT, WA. 98203 <br /> SYMBOL LEGEND SCOPE OF WORK WIRE LEGEND <br /> SYM DESCRIPTION MODEL# MANUFACTURER BACK BOX THIS SCOPE OF WORK INCLUDES: ALL WIRING AND INSTALLATION METHODS SHALL BE IN COMPLIANCE WITH CURRENT RELEVANT <br /> NATIONAL AND LOCAL ELECTRICAL CODE ARTICLES AND RELATED SECTION CODE REQUIREMENTS. <br /> Nnc�« NAC POWER SUPPLY-6A BPS6A EST INCLUDED-17"H X 13"W X 3.5"D ADDITION OF THREE(3)SINGLE CLASSROOM PORTABLE BUILDINGS AT VIEW RIDGE ELEMENTARY <br /> a SIGA-CCiS MODULE SCHOOL.THE DESIGN WILL BE BASED ON ADDING TO THE EXISTING VIGILANT FIRE ALARM PANEL IN WIRING INSTALLATION NOTES: <br /> DOUBLE ACTION PULL STATION THE ADMIN BUILDING AND WILL CONSIST OF ONE(1)HEAT DETECTOR WITH A REMOTE LED,TWO(2) 'LABEL ALL ZONE WIRES WITH ZONE NUMBER TAG AND DESCRIPTION. <br /> ❑F STANDARD SIGA-278 EST SINGLE GANG,2-1/2"DEEP SMOKE DETECTORS,ONE(1)PULL STATION,ONE(1)POWER SUPPLY,TWO(2)INDOOR `LABEL ALL SIGNAL CIRCUIT WIRES WITH SIGNAL CIRCUIT NUMBER TAG AND DESCRIPTION. <br /> HORN/STROBE,AND ONE(1)OUTDOOR HORN/STROBES FOR PORTABLES P4 AND P5 ONLY. `LABEL ALL NETWORK,ANNUNCIATOR AND 110 CONTROL CIRCUIT WIRING WITH CIRCUIT NUMBER <br /> O ADDRESSABLE ROR HEAT SIGA-HRD EST 4"OCTAGON BOX,1-1/2"DEEP TAG AND DESCRIPTION. <br /> wF SIGA-SB4-STANDARD BASE `VERIFY WITH OWNER AND GENERAL CONTRACTOR THAT OPEN CABLE IS ALLOWED ON SPECIFIC <br /> Q ISOLATOR MODULE SIGA-IM2 EST 4"SQUARE BOX,1-1/2"DEEP,DOUBLE GANG DESIGN CRITERIA APPLICABLE STANDARDS AND GUIDANCE: SITE.(FPL,FPLP,RISER,OR 2 HOUR RATED) <br /> COVER `WHERE REQUIRED,OUR DRAWINGS WILL NOTE WIRE OR PATHWAY REQUIRING SURVIVABILITY. <br /> 4"SQUARE BOX,1-1/2"DEEP,SINGLE GANG NFPA 72,2016 EDITION SUBSTITUTE THE RELEVANT CABLE WITH AN EQUIVALENT CABLE COMPATIBLE WITH THE MEANS OF <br /> }( REMOTE ALARM LED-CEILING SIGA-LED EST COVER 20181FC WITH WASHINGTON STATE AMENDMENTS. SURVIVABILITY.THIS OFTEN INCLUDES;CI-C OR CI CABLE(CIRCUIT INTEGRITY),CONCRETE <br /> ENCASEMENT OR OTHER MEANS AS APPROVED BY THE AHJ.REFER TO NFPA 72 FOR FURTHER <br /> O STANDARD ADDRESSABLE SMOKE SIGA-OSD EST 4"OCTAGON BOX,1-1/2"DEEP OCCUPANCY/USE CLASSIFICATIONS: INFORMATION. <br /> SIGASB4-STANDARD BASE <br /> HORN/STROBE-CEILING MOUNT 4"SQUARE W/EST MODEL"GRSW-10" E-EDUCATIONAL NON PLENUM: SINGLE COND.: PLENUM RATED: <br /> COLOR:WHITE,MARKING:FIRE,LENS:CLEAR GCAVWF EST WIRING PLATE CIRCUIT DESCRIPTION (FPLR,FPL) (THHN,TFFN) (FPLP) <br /> DOCUMENTATION AVAILABLE TO CONVERGINT TECHNOLOGIES <br /> WEATHERPROOF HORN/STROBE-WALL MOUNT WG4WF- EST EST MODEL"449" A ZONE/INPUT CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> wp COLOR:WHITE,MARKING:FIRE,LENS:CLEAR HVMHC DYKEMAN ARCHITECTURE+DESIGN 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> ELECTRICAL SITE PLAN-VIEW RIDGE ES PG:E1.01 DATED 04/28/2023 C NAC CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> ELECTRICAL FLOOR PLAN PG:E2.01 DATED 04/28/2023 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] DESIGNER OF RECORD <br /> D MASS.NOTIFICATION NAC CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 6120UL ROEERT OR-RICIt3 <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] NICH N <br /> FIRE.LL sYsT Ms <br /> E DOOR HOLDER/CONTROL CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> CONTACT INFORMATION 2COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] CERTIF e12- <br /> F FAN/HVAC SHUTDOWN BELDEN 5120UL (2)#14 AWG BELDEN 612OUL EXFmE lbsn oidn t `, <br /> PROJECT MANAGER FIRE ALARM DESIGNER 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] FOR VERIFICATION, <br /> GLENN SMITH ROBERT RICKS G FUTURE ADA NAC BELDEN 5120UL (2)#14 AWG BELDEN 6120UL PLEASE NSm:wYhy NICEr ORG <br /> GLEN(425y SMIT0 ROBE2T.RIC0 CIRCUIT 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> GLENN.SMITH@CONVERGINT.COM ROBERT.RICKS@CONVERGINT.COM <br /> SALES REPRESENTATIVE H PHONE CIRCUIT BELDEN 5220FL N/A BELDEN 6220FL �- <br /> PETER CAVALIERE 2 COND.16 AWG SHIELDED [3.90][65.5pF/FT] [3.850][77pF/FT] <br /> (425}272-2250 J SPEAKER CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> PETE.CAVALIERE@CONVERGINT.COM 2 COND.16 AWG [3.850][24pF/FT] [3.85C][37pF/FT] 7_ <br /> L ELEVATOR CONTROL BELDEN 5120UL (2)#14 AWG BELDEN 612OUL � <br /> SHEET LIST TABLE 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> E SHEET NULBERI SHEET TITLE M AUDIO RISER BELDEN 5220FL N/A BELDEN 6220FL <br /> FA-0-1 COVER SHEET 2 COND.16 AWG SHIELDED [3.90][65.5pF/FT] [3.850][77pF/FT] <br /> FA-1-6 1 PARTIAL SITE PLAN <br /> FA-1-1 PORTABLES P3-P5 N NETWORK COMMUNICATIONS BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> 0 FA-0-1 DEVICE DETAILS <br /> FA-0-2 DEVICE DETAILS 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> P 24VDC AU X.POWER BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> Q VESDA NET BELDEN 9841 N/A BELDEN 89841 <br /> View <br /> 2 COND.22 AWG [240][12.8pF/FPF/FT] [240][72pFIFT] <br /> Rttfge R REMOTE LED CIRCUIT BELDEN 5220UL (2)#16AWG BELDEN 6220UL <br /> A£� O 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> � SS p f lem e n to ry S ADDRESSABLE DATA SLC LOOP BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> th2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> 001 <br /> VIEW <br /> ( t / �` T1 ANALOG TWO-WAY COMM.CABLE N/A RATH RP66010001 <br /> Y 1 E Y< ty ti7 E 2COND.18 AWG NIA [2-HOURCIC] <br /> �S T2 ANALOG TWO-WAY COMM.CABLE RATH 66120 NIA N/A <br /> t� A �1!SON 2 COND.18 AWG [2-HOUR] <br /> 1Y1 1"l it f �/ TP ANALOG TWO-WAY POWER CABLE N/A RATH R66010001 <br /> 2 COND.18 AWG WA [2-HOUR CIC] <br /> S` Sw U SUPPRESSION RELEASING CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] uAre <br /> VIEW R104GE- MADISON 0512.a23 <br /> W SINGLE MODE FIBER NETWORK BUDGET SMXL02/SMXHI2:15/25 dBm ISSUEDFORPERMIT <br /> 8.3p SM CONNECTOR:DUPLEX SC <br /> X MULTIMODE FIBER NETWORK BUDGET MMXVR:10 dBm <br /> 50/125p,62.5/125p OR 100/140p MM CONNECTOR:ST <br /> Y TWO-WAY COMMUNICATIONS BELDEN 1583A N/A BELDEN 1585A <br /> �(/ CAT5E-(4)PAIR 22 AWG <br /> El FIR E/SMOKE DAMPER INTERFACE BELDEN 5120UL (2)#14 AWG BELDEN 6120UL <br /> C) ©2023 Micros Corporation©2023 TomTom 2 CONSM 14 AWG [2.43Q][23pF/FT] [2.430][37pF/FT] <br /> EpOIEli, <br /> U NOTE:ALL LISTED RESISTANCE AND CAPACITANCE ARE CONDUCTOR TO CONDUCTOR.ALL PRaECT pEsrcxMe: ROMRT It <br /> a VICINITY MAP <br /> 1V, RESISTANCE VALUES ARE PER 1000 FEET. <br /> U <br /> Q <br /> U EVERETT SD-VIEW RIDGE ES <br /> F PORTABLES P3,P4,P5 <br /> 202 ALDER STREET <br /> to <br /> M EVERETT,WA.98203 <br /> x <br /> v <br /> N <br /> Oz COVER SHEET <br /> 0 FIRE ALARM SYSTEM <br /> z <br /> wlxq. <br /> o FA-0-1 <br /> tl <br />
The URL can be used to link to this page
Your browser does not support the video tag.