Special Building Type:Farm Building or
<br /> Greenhouse? No Normal Building IBC 2009.2021,Tab'e 160.1.3
<br /> Does Roof Support Ceiling? No 16C 2009 2021.Tab'e 1604.3 and IRC 2009 2021.Table R301.7
<br /> Ceiling Type Non-Plaster IBC 2009-2021,Tab'e 16043 and IRC 2009.2021.Table 111301.7
<br /> Wall Finish Type Other Brittle Finishes 16C 2009-2021,Table I&W 3 and IRC 2009.2021,Table R301.7
<br /> Selected Deflection Span Limit-Roof ST LI sT,roo f =180
<br /> Selected Deflection Span Limit-Roof LT LILT,roof =120
<br /> Selected Deflection Span Limit-Ceiling ST L/ST,Ce1) = 240
<br /> Selected Deflection Span Limit-Ceiling LT LILT,,,❑ = 180
<br /> Selected Deflection Span Limit-Floor ST LIsT,floor =;360
<br /> Selected Deflection Span Limit-Floor LT LILT,floor --240
<br /> Selected Deflection Span Limit-Wall ST LIsT,wo)( =240
<br /> Selected Deflection Span Limit-Wall LT LI LT,wolt =1
<br /> Deflection Span Limits Aspirin _
<br /> Member Type type Short-Term(L,Lr,S,or W)Dy,(T,') Long-Term(kD•L)DLT(l.i)
<br /> Roof 180 120
<br /> Ceiling 240 180
<br /> Floor 360 240
<br /> Wall 240 1
<br /> Deflection Span Limit-Roof ST LAT,roo f =180
<br /> Deflection Span Limit-Roof LT L/LT,roof =120
<br /> Deflection Span Limit-Ceiling ST L/ST,Ceit = 240
<br /> Deflection Span Limit-Ceiling LT L/LTjCeit = 180
<br /> Deflection Span Limit-Floor ST LlsT fioor =360
<br /> Deflection Span Limit-Floor LT L/LT,floor =240
<br /> Deflection Span Limit-Wall ST L/sT,woii =240
<br /> Deflection Span Limit-Wall LT LI LT,woll =1
<br /> Absolute Deflection Limit Ati,n = 1 in
<br /> Building Geometry
<br /> Number of Stories nalory= 2
<br /> Roof Slope a= 1:12
<br /> Default Bearing Length lb= 3 in
<br /> Default Member Spacings spacings=
<br /> Rafters a„,(in) Joists aja,,(in) I Wall Studs s,,,,(in)
<br /> 16 161 _ 16
<br /> Top Floor Height Dimensions htop,floor =
<br /> Story Height Floor to Eave)h,I,,.y lift) Headroom(Floor to Ceiling)h,,a(ft) I window Height(Floor to Top of Window)h,,;,,,,.(ft)
<br /> 12 10 8
<br /> Lower Floors Height Dimensions hiower.floors =
<br /> i Story Height(Floor to Floor)h,,,,,,(R) Headroom(Floor to Ceiling)ht„a(R) Window Height(Floor to Top of Ylndow)ki,s...(A)
<br /> 12 10I 8 g� FLU
<br /> Lower Floors Window Height hwindow = 8 ft,0 in
<br /> �A
<br /> Assumptions I + 1
<br /> ix,vt.
<br /> Greenfield Rev 3 Page 11 of 52
<br />
|