Field <br /> Report <br /> 3d-0 <br /> GENERAL NOTES LZ <br /> 8'1" I.W. V-4" 12'-10" <br /> 1. ALL EXTERIOR WARM WALLS TO BE 2x8 STUDS ..F,.la <br /> 3'1- 3'♦" 1.,., 8'3" 16"O.C.TYPICAL,WITH R-21 INSULATION. <br /> 2.ALL HEADERS ON UPPER FLOOR TO BE 4x8 <br /> DOUGLAS FUR#2 UNLESS NOTED OTHERWISE. _ .:a.y w.ra m..eMa.aropi.<•.M•..rt <br /> 4020 XO SL R. <br /> 6040 Xj SLDR. 3.FUR-OUT HEADERS TO MATCH 2.6 WALLS. C.pyaanr2o2 i-R.p.I.QW23 Fria R.P. <br /> 4.PROVIDE SOLID BLOCKING UNDER ALL <br /> PSS 38"x48 .6. (EGR SS) BEARING WALLS. <br /> 5.INLINE FRAMING-SINGLE TOP PLATE STRAP <br /> � <br /> o 60'k36" 0 SPLICES AND CORNERS,EXCEPT AS NOTED SOAKTUB FOR SHEAR TRANSFER. <br /> G <br /> FAN 0 VAULTED CLG. 6.ALL GUARDRAILS PER MANUFACTURERS <br /> W.I.C. VT <br /> O ITH HIP ROOF SPECIFICATIONS.SUPPORTS CAPABLE OF <br /> Cor 50 CFM RESISTING A SINGLE CONCENTRATED LOAD <br /> i <br /> � 24 64 MASTER 2 8 OF 200 POUNDS,APPLIED IN ANY DIRECTION <br /> BATH AT ANY POINT ALONG THE TOP OF THE RAIL. <br /> VN L <br /> 3-1" T-0" O 7,TUB/SHOWER UNITS SHALL HAVE FIRE BLOCKING <br /> MASTER BETWEEN WALL STUDS AND WATERPROOF <br /> BEDROOM SURROUNDS TO+72"FROM DRAIN.GLAZING, <br /> el o INCLUDING WINDOWS WITH IN+72"OF DRAIN,SHALL <br /> ...... <br /> T BE SAFETY GLASS.SHOWER FLOW IS D <br /> PSS 2 5WALLFROM <br /> M UttR11N.WOOD FRAMING TOBE PROTECTED <br /> SLOPE SLOPE Pg FROM WATER SPLASH AND MOISTURE. <br /> S.ALL BATHROOM FANS,KITCHEN HOODS,AND DRYER <br /> ---P&S---�- DUCTS SHALL BE EXHAUSTED THRU THE ATTIC TO THE <br /> ROOF OR THRU THE FLOOR SYSTEM AN OUTSIDE O <br /> tq WALL.ALL WALL DUCTS SHALL TERMINATE AT LEAST <br /> �0 lye p 36"FROM A WINDOW OPENING. <br /> N 1 p <br /> 9.ONE WINDOW PER BEDROOM SHALL MEET <br /> EGRESS CODE PER 20181RC R310.1 <br /> S2 BED#2 32"xg0" 10.UNDER ALL PARALLEL BEARING WALLS,USE DOUBLE <br /> rc cPT TUB/SHWR. (p m 6 JOISTS OR AS NOTED ON PLAN,DOUBLE JOISTS <br /> UNDER ALL NON-BEARING PARALLEL WALLS. <br /> 11.WHOLE HOUSE INDOOR VENTILATION SYSTEM WITH <br /> FAN § 24 HOUR PROGRAMMABLE TIMER.RETURN AIR <br /> VT0 TO BE SUPPLIED BY HEATING SYSTEM. <br /> 50 CFM ELECTRIC `p <br /> A 8 S BATH FURNACE N 12.MAX.HOT WATER TEMP.DISCHARGING INTO A O <br /> 6 <br /> BATHTUB OR WHIRLPOOL BATH SHALL BE LIMITED <br /> -aa ® VINYL TO 120"F.THE WATER HEATER SHALL NOT BE <br /> CONSIDERED A CONTROL FOR MEETING THIS PROVISION. <br /> Vi0 WASH N 13. cm <br /> ALL OPENINGS MADE IN WALLS,FLOORS,OR CEILINGS <br /> FOR THE PASSAGE OF PIPES,STRAINER PLATES ON <br /> DRAIN INLETS,AND METER BOXES SHALL MEET THE <br /> REQUIREMENTS OF THE 2018 UPC SECTION 313.12 <br /> m LAUNDRY 4,$„ 6,�„ 2'-6" 3'-5" �+'3 3'10" cu."r <br /> wm � 14.ALL FLASHING TO BE IN COMPLIANCE WITH <br /> W.H.FAN �`, 20161RC,SECTION R703.4. <br /> O 463 LEGEND: <br /> CFM <br /> w <br /> LINEN N <br /> ------.P$$_----- o --------------- r SMOKE DETECTOR110V <br /> H p O INTERCONNECTED W/BATTERY <br /> BACK-UP <br /> 5 n e e O 5 u 63 CARBON MONOXIDE DETECTOR 110V <br /> SI-PASS BI-PAS9 paw 0 INTERCONNECTED W/BATTERY <br /> O s d BACK-UP PER IRC315 �MN• <br /> T4" 3'-0" EZ 7'-0" Fr (S.G.) SAFETY GLASS <br /> VT O VENT TO OUTSIDE <br /> FAN-VENT TO <br /> y 0 OUTSIDE <br /> 50 CFM MINIMUM <br /> § BED#3 BED#2 All tans switched intermittently, <br /> CPT CPt 1.0 <br /> 8one max. <br /> ART <br /> LEDGE <br /> 2040 l <br /> ROOF VENTILATION CALCULATION <br /> (EGRESS) (EGRESS) <br /> VENTED SPACE 1 2,852 SF <br /> 4050 XO SL R. 7050 XOX SL R. vEN 1—RECPSR 17.68 SF/2,646 SQ.IN.(11150 PER R808.2) / <br /> G.C.TO PROVIDE A MINIMUM OF 17.68 SF FREE REA OF VENTING IN -( <br /> Y COMPLIANCE WITH Fall <br /> 10'," 13'-6" 2'-S" 1, 3'3" <br /> 24'-1 6'-0" UPPER FLOOR PLAN --- <br /> W-01 SEE GENERAL NOTES SCALE:1/4"=V-0" <br /> I <br /> i <br /> • <br /> G <br /> 1/4"=T_0" <br /> UPPER FLOOR PLAN <br /> A6 <br />